Comparison of the standards for air kerma of the VSL and the BIPM for 60Co gamma radiation

被引:2
|
作者
Kessler, C. [1 ]
Allisy-Roberts, P. J. [1 ]
de Prez, L. A. [2 ]
van Dijk, E. [2 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] Dutch Metrology Inst VSL, Delft, Netherlands
关键词
D O I
10.1088/0026-1394/47/1A/06015
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An indirect comparison of the standards for air kerma of the Dutch Metrology Institute (VSL), The Netherlands, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the Co-60 radiation beam of the BIPM in September 2005. The comparison result, based on the calibration coefficients for three transfer standards and expressed as a ratio of the VSL and the BIPM standards for air kerma, is 0.9985 with a combined standard uncertainty of 2.2 x 10(-3). The latest result agrees with the result of the previous comparison in Co-60 gamma rays, made in 1996 and updated for recent changes made to the standards to give a value of 0.9982 (37). The degrees of equivalence between the VSL and the other participants in the key comparison BIPM.RI(I)-K1 have been calculated and the results are presented in the form of a matrix. A graphical presentation is also given.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Comparison of the standards for absorbed dose to water of the ARPANSA and the BIPM for 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Allisy-Roberts, P. J.
    Butler, D.
    Lye, J.
    Webb, D.
    METROLOGIA, 2012, 49
  • [32] Comparison of the standards for absorbed dose to water of the NRC and the BIPM for 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Allisy-Roberts, P. J.
    McCaffrey, J. P.
    McEwen, M. R.
    Ross, C. K.
    METROLOGIA, 2010, 47
  • [33] Comparison of the standards for absorbed dose to water of the VSL, The Netherlands, and the BIPM for 60Co γ rays
    Kessler, C.
    Burns, D.
    Jansen, B. J.
    de Pooter, J. A.
    de Prez, L. A.
    METROLOGIA, 2018, 55
  • [34] Key comparison BIPM.RI(I)-K5 of the air kerma standards of the VSL and the BIPM in 137Cs gamma radiation
    Kessler, C.
    Burns, D. T.
    Jansen, B. J.
    De Pooter, J. A.
    METROLOGIA, 2016, 53
  • [35] Comparison of the standards for absorbed dose to water of the BEV, Austria, and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Steurer, A.
    Tiefenboeck, W.
    Gabris, F.
    METROLOGIA, 2010, 47
  • [36] Comparison of the standards for air kerma of the KRISS and the BIPM for 137Cs gamma radiation
    Kessler, C.
    Roger, P.
    Allisy-Roberts, P. J.
    Yi, Chul-Young
    METROLOGIA, 2010, 47
  • [37] Comparison of the standards for air kerma of the BEV and the BIPM for 137Cs gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Steurer, A.
    Tiefenboeck, W.
    Gabris, F.
    METROLOGIA, 2010, 47
  • [38] Comparison of the standards for air kerma of the MKEH and the BIPM for 137Cs gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Csete, I.
    Machula, G.
    METROLOGIA, 2010, 47
  • [39] Comparison of the standards for air kerma of the VNIIM and the BIPM for 137Cs gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Oborin, A. V.
    Villevalde, A. Y.
    METROLOGIA, 2011, 48
  • [40] Comparison of the air kerma standards for 137Cs and 60Co gamma-ray beams between the IAEA and the NIST
    Minniti, Ronaldo
    Czap, Ladislav
    METROLOGIA, 2011, 48