Comparison of the standards for air kerma of the VSL and the BIPM for 60Co gamma radiation

被引:2
|
作者
Kessler, C. [1 ]
Allisy-Roberts, P. J. [1 ]
de Prez, L. A. [2 ]
van Dijk, E. [2 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] Dutch Metrology Inst VSL, Delft, Netherlands
关键词
D O I
10.1088/0026-1394/47/1A/06015
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An indirect comparison of the standards for air kerma of the Dutch Metrology Institute (VSL), The Netherlands, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the Co-60 radiation beam of the BIPM in September 2005. The comparison result, based on the calibration coefficients for three transfer standards and expressed as a ratio of the VSL and the BIPM standards for air kerma, is 0.9985 with a combined standard uncertainty of 2.2 x 10(-3). The latest result agrees with the result of the previous comparison in Co-60 gamma rays, made in 1996 and updated for recent changes made to the standards to give a value of 0.9982 (37). The degrees of equivalence between the VSL and the other participants in the key comparison BIPM.RI(I)-K1 have been calculated and the results are presented in the form of a matrix. A graphical presentation is also given.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the BFKH, Hungary and the BIPM in 60Co gamma radiation
    Kessler C.
    Burns D.
    Finta V.
    Metrologia, 2023, 60 (1 A)
  • [22] Re-evaluation of the BIPM international standard for air kerma in 60Co gamma radiation
    Burns, David T.
    Allisy, Penelope J.
    Kessler, Cecilia
    METROLOGIA, 2007, 44 (06) : L53 - L56
  • [23] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the KRISS, Republic of Korea, and the BIPM in 60Co gamma radiation
    Kessler C.
    Burns D.
    Yi C.-Y.
    Kim Y.H.
    Seong Y.M.
    Metrologia, 2022, 59 (1 A)
  • [24] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NPL, United Kingdom and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Kelly, M.
    Maughan, D. J.
    Bass, G. A.
    Homer, M. J.
    METROLOGIA, 2019, 56 (1A)
  • [25] f Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NIM, China and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Wang, K.
    Fan, Y.
    Jin, S.
    Yang, X.
    METROLOGIA, 2016, 53
  • [27] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the IST-LPSR, Portugal and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Cardoso, J.
    METROLOGIA, 2018, 55
  • [28] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the SCK.CEN, Belgium and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Mihailescu, L. C.
    Chiriotti, S.
    METROLOGIA, 2017, 54
  • [29] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the LNE-LNHB, France and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Delaunay, F.
    Donois, M.
    METROLOGIA, 2013, 50
  • [30] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the ENEA-INMRI, Italy and the BIPM in 60Co gamma radiation
    Kessler, C.
    Pinto, M.
    Cappadozzi, G.
    Silvestri, C.
    Bovi, M.
    Toni, M. P.
    METROLOGIA, 2015, 52