Repeatability of central corneal thickness measurements of donor corneas in preservation chamber using Fourier-domain anterior segment optical coherence tomography

被引:5
|
作者
Golla, Abhinav [1 ]
Wang, Li [1 ]
Morris, Caleb [1 ]
Weikert, Mitchell P. [1 ,2 ]
Khandelwal, Sumitra S. [1 ,2 ]
机构
[1] Baylor Coll Med, Cullen Eye Inst, 6565 Fannin St NC505B, Houston, TX 77030 USA
[2] Lions Eye Bank Texas, 1977 Butler Blvd, Houston, TX 77030 USA
关键词
Central corneal thickness; Optical coherence tomography; Repeatability; Donor cornea; Preservation;
D O I
10.1007/s10561-018-9724-z
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
To evaluate the repeatability of central corneal thickness (CCT) measurements in donor corneas using optical coherence tomography (OCT, RTVueOptovue, Inc., Fremont, CA). Consecutive corneas were measured by a single observer using the RTVue. All corneas were preserved in the Transend chamber and Life4 degrees C media (Numedis, Inc., Isanti, MN/USA) and stored at 4 degrees C. The repeatability was evaluated using a pooled within-subject standard deviation (SD), coefficient of variation (CoV), and intraclass correlation coefficient (ICC). To investigate inter-observer repeatability, a second observer independently measured the CCT for each image scan. CCT was measured in 32 eyes from 18 donors. Measurements were independently repeated by a second observer. The corneas had a mean CCT of 490.99m +/- 65.95 (381-642) as measured by Observer 1. For observer 1, the SD value for the CCT was 2.94m, the CoV value was 0.597%, and the ICC value was 0.998 (95% CI 0.996, 0.999). For observer 2, the SD value was 5.91m, the CoV value was 1.21%, and the ICC value was 0.992 (95% CI 0.985, 0.996). The Kappa statistic 21.88% with a p value<0.001. The Bland-Altman plot shows that the average CCT measurements between the two observers were within 20m of each other. The CCT measurements of donor corneas in the preservation chamber using Fourier domain OCT is highly repeatable.
引用
收藏
页码:717 / 720
页数:4
相关论文
共 50 条
  • [41] Influence of contact lens wearing on whole corneal thickness and corneal epithelial thickness measured with Fourier-domain optical coherence tomography
    Wasielica-Poslednik, Joanna
    Sievers, Marcel Sebastian
    Lisch, Walter
    Weyer, Veronika
    Pfeiffer, Norbert
    Gericke, Adrian
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [42] Central corneal thickness measurements obtained with anterior segment spectral domain optical coherence tomography compared to ultrasound pachymetry in healthy subjects
    Vollmer, Lori
    Sowka, Joseph
    Pizzimenti, Joseph
    Yu, Xinha
    OPTOMETRY-JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 2012, 83 (05) : 167 - 172
  • [43] Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography in the Measurement of Thinnest Corneal Thickness in Keratoconus
    Wang, Chunxiao
    Xia, Xueying
    Tian, Bishan
    Zhou, Shiyou
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [44] Comparison of central corneal thickness using anterior segment optical coherence tomography vs ultrasound pachymetry
    Kim, Hanna Y.
    Budenz, Donald L.
    Lee, Pak S.
    Feuer, William J.
    Barton, Keith
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (02) : 228 - 232
  • [45] Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mo
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 884 - 884
  • [46] Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    PLOS ONE, 2021, 16 (05):
  • [47] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [48] Assessment of corneal epithelial thickness in dry eye patients evaluated by Fourier-domain optical coherence tomography
    Cui, Xinhan
    Hong, Jiaxu
    Wang, Fei
    Yang, Yujing
    Xu, JianJiang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [49] Fourier-domain optical coherence tomography-guided phototherapeutic keratectomy for the treatment of anterior corneal scarring
    Yang, Yu-Li
    Jian, Qian
    Liu, Bo
    Wang, Ke
    Chen, Yu-Juan
    Tan, Lian
    Pu, Mei-Jun
    Liu, Yong
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (11) : 1720 - 1726
  • [50] Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry
    Chen, Shihao
    Huang, Jinhai
    Wen, Daizong
    Chen, Wuhe
    Huang, David
    Wang, Qinmei
    ACTA OPHTHALMOLOGICA, 2012, 90 (05) : 449 - 455