Serum D-dimer is a sensitive test for the detection of acute aortic dissection: A pooled meta-analysis

被引:74
|
作者
Marill, Keith A. [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Emergency Med, Boston, MA 02114 USA
来源
JOURNAL OF EMERGENCY MEDICINE | 2008年 / 34卷 / 04期
关键词
acute; aorta; dissection; D-dimer; sensitivity;
D O I
10.1016/j.jemermed.2007.06.030
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
0 Abstract-Acute aortic dissection is a rare but devastating condition with high mortality. Unfortunately, there is no sensitive screening indicator of disease in common use. The objective of this study was to assess the sensitivity and utility of the serum D-dimer as a test for acute aortic dissection. A pooled analysis was performed of all original research studies testing the sensitivity of serum D-dimer for acute aortic dissection. A search of MEDLINE, EMBASE, and the Cochrane Register using the terms "aortic dissection" and "d-dimer" was made of all English language publications. All original reports of consecutively enrolled patients with acute aortic dissection and a measured serum D-dimer were included. Case reports were excluded. A value of 0.5 microgram per milliliter was defined as the threshold for a positive D-dimer. The primary outcome was the pooled sensitivity of the D-dimer test for acute aortic dissection. There were 21 original reports of patients with acute aortic dissection and D-dimer measurements. Eleven studies were included and a total of 349 acute aortic dissection patients were described. The sensitivity of the D-dimer test was 327/349, 94% (95% confidence interval 91-96), and the point estimate was essentially unchanged in a sensitivity analysis, 183/192, 95% (95% confidence interval 91-98). Specificity ranged from 40% to 100%. Serum D-dimer is sensitive for acute aortic dissection and potentially represents a useful test for patients who present with a low likelihood of this disease. (C) 2008 Elsevier Inc.
引用
收藏
页码:367 / 376
页数:10
相关论文
共 50 条
  • [21] Diagnostic Accuracy of D-Dimer for Acute Aortic Syndromes: Systematic Review and Meta-Analysis
    Essat, Munira
    Goodacre, Steve
    Pandor, Abdullah
    Ren, Sa
    Ren, Shijie
    Clowes, Mark
    ANNALS OF EMERGENCY MEDICINE, 2024, 84 (04) : 409 - 421
  • [22] Accuracy of using serum D-dimer for diagnosis of acute intestinal ischemia A meta-analysis
    Sun, Da-Li
    Li, Shu-Min
    Cen, Yun-Yun
    Xu, Qing-Wen
    Li, Yi-Jun
    Sun, Yan-Bo
    Qi, Yu-Xing
    Lin, Yue-Ying
    Yang, Ting
    An, Li-Ya
    Su, Kun
    Li, Wei-Ming
    Xu, Peng-Yuan
    MEDICINE, 2017, 96 (13)
  • [23] Impact of D-dimer on in-hospital mortality following aortic dissection: A systematic review and meta-analysis
    Srikanth, Sashwath
    Abrishami, Shabnam
    Subramanian, Lakshmi
    Mahadevaiah, Ashwini
    Vyas, Ankit
    Jain, Akhil
    Nathaniel, Sangeetha
    Gnanaguruparan, Subramanian
    Desai, Rupak
    WORLD JOURNAL OF CARDIOLOGY, 2024, 16 (06): : 355 - 362
  • [24] IMPACT OF D-DIMER ON IN-HOSPITAL MORTALITY FOLLOWING AORTIC DISSECTION: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Srikanth, Sashwath
    Mahadevaiah, Ashwini
    Abrishami, Shabnam
    Niaz, Rabiya
    Aqeel, Mariam
    Narula, Harshit
    Thota, Anjani
    Saeed, Memoona
    Singh, Monika
    Yarrarapu, Siva Naga
    Desai, Rupak
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 2060 - 2060
  • [25] Cost associated with D-Dimer screening for acute aortic dissection
    Theodoros Moysidis
    Marc Lohmann
    Sarah Lutkewitz
    Guido Kemmeries
    Knut Kröger
    Advances in Therapy, 2011, 28 : 1038 - 1044
  • [26] Cost associated with D-Dimer screening for acute aortic dissection
    Moysidis, Theodoros
    Lohmann, Marc
    Lutkewitz, Sarah
    Kemmeries, Guido
    Kroeger, Knut
    ADVANCES IN THERAPY, 2011, 28 (11) : 1038 - 1044
  • [27] Plasma D-dimer in the diagnosis of acute aortic dissection: reply
    Sodeck, Gottfried
    Domanovits, Hans
    EUROPEAN HEART JOURNAL, 2008, 29 (09) : 1207 - 1208
  • [28] THE VALUE OF D-DIMER IN ACUTE AORTIC DISSECTION: THE EXPERIENCE OF CHINA
    Li, W.
    Fan, X.
    Xu, J.
    Zhang, W.
    Wang, X.
    Sun, K.
    Hui, R.
    ATHEROSCLEROSIS SUPPLEMENTS, 2010, 11 (02) : 197 - 197
  • [29] Diagnostic value of circulating D-Dimer in acute aortic dissection
    Ohlmann, P.
    Faure, A.
    Morel, O.
    Petit, H.
    Kabbaj, H.
    Roul, G.
    Eisenmann, B.
    Bareiss, P.
    EUROPEAN HEART JOURNAL, 2005, 26 : 188 - 188
  • [30] Combined use of aortic dissection detection risk score and D-dimer in the diagnostic workup of suspected acute aortic dissection
    Nazerian, Peiman
    Morello, Fulvio
    Vanni, Simone
    Bono, Alessia
    Castelli, Matteo
    Forno, Daniela
    Gigli, Chiara
    Soardo, Flavia
    Carbone, Federica
    Lupia, Enrico
    Grifoni, Stefano
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 175 (01) : 78 - 82