Potentiometric enzyme electrode in a flow injection system for the determination of urea in human serum samples

被引:52
|
作者
Walcerz, I [1 ]
Glab, S [1 ]
Koncki, R [1 ]
机构
[1] Univ Warsaw, Dept Chem, PL-02093 Warsaw, Poland
关键词
urea; enzyme electrode; flow injection analysis; serum;
D O I
10.1016/S0003-2670(98)00222-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A urea biosensor with urease covalently bound directly to the membrane of the ammonium ion selective electrode has been developed. The enzyme electrode was tested in single and double channel how injection analysis (FIA) systems. Optimised measurement conditions allowed determination of urea within the linear range of 0.5-8 mM in the single channel and of 1-10 mM in the double channel FIA system. The response time of the biosensor was short enabling frequent sample injections (every 1.5-3 min). Long term stability of the enzyme electrode allows application of the same biosensor in the FIA systems for up to two months. Under optimised conditions the determination of urea is possible at physiological and pathological levels. The results of urea determination in real, human serum samples were in good agreement with those obtained by routine clinical analysis methods. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:129 / 137
页数:9
相关论文
共 50 条
  • [21] Carbon paste electrode for the potentiometric flow injection analysis of drotaverine hydrochloride in serum and urine
    Issa, YM
    Ibrahim, H
    Abu-Shawish, HM
    MICROCHIMICA ACTA, 2005, 150 (01) : 47 - 54
  • [22] Carbon Paste Electrode for the Potentiometric Flow Injection Analysis of Drotaverine Hydrochloride in Serum and Urine
    Yousry M. Issa
    Hosny Ibrahim
    Hazem M. Abu-Shawish
    Microchimica Acta, 2005, 150 : 47 - 54
  • [23] Green potentiometric electrode for determination of salbutamol in biological samples
    Elbalkiny, Heba T.
    Samir, Ahmed
    Analytical Biochemistry, 2022, 659
  • [24] Green potentiometric electrode for determination of salbutamol in biological samples
    Elbalkiny, Heba T.
    Samir, Ahmed
    ANALYTICAL BIOCHEMISTRY, 2022, 659
  • [26] Potentiometric enzyme electrode for urea based on electrochemically prepared polypyrrole membranes
    Hernandez, EC
    Witkowski, A
    Daunert, S
    Bachas, LG
    MIKROCHIMICA ACTA, 1995, 121 (1-4) : 63 - 72
  • [27] ENZYMATIC FLOW-INJECTION DETERMINATION OF UREA IN BLOOD-SERUM USING POTENTIOMETRIC GAS SENSOR WITH INTERNAL NONACTIN BASED ISE
    KRAWCZYK, TKV
    TROJANOWICZ, M
    LEWENSTAM, A
    TALANTA, 1994, 41 (08) : 1229 - 1236
  • [28] SPECTROPHOTOMETRIC DETERMINATION OF MAGNESIUM IN SERUM BY USING A FLOW-INJECTION SYSTEM WITH AN IMMOBILIZED ENZYME REACTOR
    FERNANDEZROMERO, JM
    DECASTRO, MDL
    VALCARCEL, M
    QUILESZAFRA, R
    ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 447 - 452
  • [29] Flow Injection Potentiometric Determination of Silver(I) in Photographic Film Developing Solution Samples by Polyvinylchloride Membrane Silver(I) Selective Electrode
    Topcu, Cihan
    Coldur, Fatih
    Andac, Muberra
    Cubuk, Osman
    Kanberoglu, Gulsah Saydan
    Caglar, Bulent
    Isildak, Ibrahim
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2016, 38 (05): : 882 - 888
  • [30] Flow injection potentiometric determination of Chlorphenoxamine Hydrochloride
    Abdel-Ghani, Nour T.
    Hussein, Salwa H.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (12) : 2077 - 2090