Effects of radiation damage and inelastic scattering on single-particle imaging of hydrated proteins with an X-ray Free-Electron Laser

被引:8
|
作者
Juncheng, E. [1 ]
Stransky, Michal [1 ,2 ]
Jurek, Zoltan [3 ,4 ]
Fortmann-Grote, Carsten [1 ,5 ]
Juha, Libor [6 ,7 ]
Santra, Robin [3 ,4 ,8 ]
Ziaja, Beata [2 ,3 ]
Mancuso, Adrian P. [1 ,9 ]
机构
[1] European XFEL, Holzkoppel 4, D-22869 Schenefeld, Germany
[2] Polish Acad Sci, Inst Nucl Phys, Radzikowskiego 152, PL-31342 Krakow, Poland
[3] Deutsch Elekt Synchrotron DESY, Ctr Free Electron Laser Sci CFEL, Notkestr 85, D-22607 Hamburg, Germany
[4] Hamburg Ctr Ultrafast Imaging, Luruper Chaussee 149, D-22761 Hamburg, Germany
[5] Max Planck Inst Evolutionary Biol, August Thienemann Str 2, D-24306 Plon, Germany
[6] Czech Acad Sci, Inst Phys, Slovankou 3, CZ-18221 Prague 8, Czech Republic
[7] Czech Acad Sci, Inst Plasma Phys, Slovankou 3, CZ-18200 Prague 8, Czech Republic
[8] Univ Hamburg, Dept Phys, Notkestr 9-11, D-22607 Hamburg, Germany
[9] La Trobe Univ, La Trobe Inst Mol Sci, Dept Chem, Melbourne, Vic 3086, Australia
基金
欧盟地平线“2020”;
关键词
DYNAMICS; SIMULATION; RADIOLYSIS; LAYER;
D O I
10.1038/s41598-021-97142-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We present a computational case study of X-ray single-particle imaging of hydrated proteins on an example of 2-Nitrogenase-Iron protein covered with water layers of various thickness, using a start-to-end simulation platform and experimental parameters of the SPB/SFX instrument at the European X-ray Free-Electron Laser facility. The simulations identify an optimal thickness of the water layer at which the effective resolution for imaging the hydrated sample becomes significantly higher than for the non-hydrated sample. This effect is lost when the water layer becomes too thick. Even though the detailed results presented pertain to the specific sample studied, the trends which we identify should also hold in a general case. We expect these findings will guide future single-particle imaging experiments using hydrated proteins.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] TEACHING THE PRINCIPLES AND APPLICATIONS OF X-RAY FREE-ELECTRON LASER RADIATION
    Tschentscher, Th.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C199 - C199
  • [42] Numerical single-particle analysis of Cherenkov free-electron laser
    Bazouband, F.
    Maraghechi, B.
    INDIAN JOURNAL OF PHYSICS, 2020, 94 (03) : 303 - 308
  • [43] Numerical single-particle analysis of Cherenkov free-electron laser
    F. Bazouband
    B. Maraghechi
    Indian Journal of Physics, 2020, 94 : 303 - 308
  • [44] Exploring the wavefront of hard X-ray free-electron laser radiation
    Simon Rutishauser
    Liubov Samoylova
    Jacek Krzywinski
    Oliver Bunk
    Jan Grünert
    Harald Sinn
    Marco Cammarata
    David M. Fritz
    Christian David
    Nature Communications, 3
  • [45] SINGLE-PARTICLE DYNAMICS OF A FREE-ELECTRON LASER WITH AXIAL FIELD
    PANDYA, TP
    BALI, LM
    BAKSHI, U
    JHA, P
    PHYSICAL REVIEW A, 1987, 35 (12): : 5131 - 5136
  • [46] FREE-ELECTRON LASER - SINGLE-PARTICLE CLASSICAL-MODEL
    BAMBINI, A
    RENIERI, A
    LETTERE AL NUOVO CIMENTO, 1978, 21 (11): : 399 - 404
  • [47] SINGLE-PARTICLE THEORY OF THE FREE-ELECTRON LASER IN A MOVING FRAME
    STENHOLM, ST
    BAMBINI, A
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1981, 17 (08) : 1363 - 1371
  • [48] Single-particle coherent diffractive imaging with a soft x-ray free electron laser: towards soot aerosol morphology
    Bogan, Michael J.
    Starodub, Dmitri
    Hampton, Christina Y.
    Sierra, Raymond G.
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2010, 43 (19)
  • [49] Imaging by intensity interferometry of x-ray fluorescence at a compact x-ray free-electron laser
    Shevchuk, Andrew S. H.
    Spence, John C. H.
    Kirian, Richard A.
    Graves, William S.
    Schmidt, Kevin E.
    PHYSICAL REVIEW A, 2021, 104 (02)
  • [50] European X-ray Free-Electron Laser
    Kovalchuk, M., V
    Blagov, A. E.
    CRYSTALLOGRAPHY REPORTS, 2022, 67 (05) : 631 - 675