Comparison of anterior chamber depth measurements using Orbscan II and IOLMaster

被引:13
|
作者
Frisch, I. B. [1 ]
Rabsilber, T. M. [1 ]
Becker, K. A. [1 ]
Reuland, A. J. [1 ]
Auffarth, G. U. [1 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, D-69120 Heidelberg, Germany
关键词
anterior chamber; IOLMaster; Orbscan II;
D O I
10.1177/112067210701700308
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To To evaluate and compare anterior chamber depth (ACD) measurements using Orbscan II (Bausch & Lomb, Rochester, NY) and IOLMaster (Carl Zeiss Meditec AG, Jena, Germany). METHODS. In this prospective clinical study, the authors measured ACD of 145 phakic eyes of 30 healthy volunteers and 115patients using Orbscan II and IOLMaster Average patient age was 52.9+/-19.4 (range 16 to 87) years. ACD was evaluated from corneal epithelium to anterior tens surface. Additionally, axial length (AL) was measured using the Zeiss IOLMaster to calculate the regression coefficient between AL and ACD. RESULTS. Mean ACD was 3.35+/-0.43 mm (range 2.01 mm to 4.37 mm) using Orbscan II and 3.36+/-0.41 mm (range 2.09 mm to 4.24 mm) using IOLMaster Mean total axial length was 24.04 mm +/-2.1 mm (range 20.7 mm to 31.41 mm). The linear regression coefficient of ACD between both methods was R=0.95. ACD and AL correlated only slightly (R=0.57). The Spearman coefficients of rank correlation were 0.94 and 0.61, respectively. A p value less than 0.01 (paired Wilcoxon test) was considered statistically significant. However, a significant difference was not calculated comparing ACD measurements using both systems and the Bland-Altman-Plot showed 95% of the differences ranging between 0.25 and -0.27 mm. CONCLUSIONS. Regarding clinical application, both systems seem to be equally good and interchangeable in clinical practice in terms of ACD evaluation.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 50 条
  • [41] Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures - response
    Cairns, G
    McGhee, CNJ
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (01): : 95 - 95
  • [42] Comparison of the anterior ocular segment measurements using swept-source optical coherent tomography and a scanning peripheral anterior chamber depth analyzer
    Toshie Furuya
    Fumihiko Mabuchi
    Tatsuya Chiba
    Satoshi Kogure
    Shigeo Tsukahara
    Kenji Kashiwagi
    Japanese Journal of Ophthalmology, 2011, 55 : 472 - 479
  • [43] Comparison of the anterior ocular segment measurements using swept-source optical coherent tomography and a scanning peripheral anterior chamber depth analyzer
    Furuya, Toshie
    Mabuchi, Fumihiko
    Chiba, Tatsuya
    Kogure, Satoshi
    Tsukahara, Shigeo
    Kashiwagi, Kenji
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2011, 55 (05) : 472 - 479
  • [44] Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures - comment
    Cheng, ACK
    Yuen, KSC
    Chan, WM
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (01): : 94 - 95
  • [45] Comparison of corneal pachymetry using ultrasound and Orbscan II
    Fakhry, MA
    Artola, A
    Belda, JL
    Ayala, MJ
    Alió, JL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02): : 248 - 252
  • [46] Corneal thickness and anterior chamber depth by Orbscan in normal and primary open-angle glaucoma patients in Korea
    Kim, Na Rae
    Kim, Chan Yun
    Oh, Jung Hyub
    Lee, Eun Suk
    JOURNAL OF GLAUCOMA, 2008, 17 (06) : 465 - 469
  • [47] Comparison of Anterior Chamber Depth and Central Corneal Thickness Measured Using Different Devices
    Jeung, Jae Gyun
    Gil, Tae Young
    Bae, Gi Hyun
    Shin, Seong Joo
    Chung, Sung Kun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (10): : 1570 - 1576
  • [48] Agreement between Orbscan II, VuMAX UBM and Artemis-2 very-high frequency ultrasound scanner for measurement of anterior chamber depth
    Al Farhan, Haya Matuoq
    BMC OPHTHALMOLOGY, 2014, 14
  • [49] Comparison of anterior chamber depth measurements of Nidek AL-Scan and Galilei Dual Scheimpflug Analyzer
    Dervisogullari, Mehmet Serdar
    Totan, Yuksel
    Guragac, Betul
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (02): : 85 - 88
  • [50] Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices
    Dominguez-Vicent, Alberto
    Monsalvez-Romin, Daniel
    Del Aguila-Carrasco, Antonio Jesus
    Garcia-Lazaro, Santiago
    Montes-Mico, Robert
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (04) : 233 - 237