Comparison of anterior chamber depth measurements using Orbscan II and IOLMaster

被引:13
|
作者
Frisch, I. B. [1 ]
Rabsilber, T. M. [1 ]
Becker, K. A. [1 ]
Reuland, A. J. [1 ]
Auffarth, G. U. [1 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, D-69120 Heidelberg, Germany
关键词
anterior chamber; IOLMaster; Orbscan II;
D O I
10.1177/112067210701700308
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To To evaluate and compare anterior chamber depth (ACD) measurements using Orbscan II (Bausch & Lomb, Rochester, NY) and IOLMaster (Carl Zeiss Meditec AG, Jena, Germany). METHODS. In this prospective clinical study, the authors measured ACD of 145 phakic eyes of 30 healthy volunteers and 115patients using Orbscan II and IOLMaster Average patient age was 52.9+/-19.4 (range 16 to 87) years. ACD was evaluated from corneal epithelium to anterior tens surface. Additionally, axial length (AL) was measured using the Zeiss IOLMaster to calculate the regression coefficient between AL and ACD. RESULTS. Mean ACD was 3.35+/-0.43 mm (range 2.01 mm to 4.37 mm) using Orbscan II and 3.36+/-0.41 mm (range 2.09 mm to 4.24 mm) using IOLMaster Mean total axial length was 24.04 mm +/-2.1 mm (range 20.7 mm to 31.41 mm). The linear regression coefficient of ACD between both methods was R=0.95. ACD and AL correlated only slightly (R=0.57). The Spearman coefficients of rank correlation were 0.94 and 0.61, respectively. A p value less than 0.01 (paired Wilcoxon test) was considered statistically significant. However, a significant difference was not calculated comparing ACD measurements using both systems and the Bland-Altman-Plot showed 95% of the differences ranging between 0.25 and -0.27 mm. CONCLUSIONS. Regarding clinical application, both systems seem to be equally good and interchangeable in clinical practice in terms of ACD evaluation.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 50 条
  • [31] Comparison of techniques for measuring anterior chamber depth: Orbscan imaging, Smith's technique, and van Herick's method
    Eperjesi, Frank
    Holden, Claire
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (03) : 449 - 454
  • [32] Comparison of axial length, anterior chamber depth and intraocular lens power between IOLMaster and ultrasound in normal, long and short eyes
    Dong, Jing
    Zhang, Yaqin
    Zhang, Haining
    Jia, Zhijie
    Zhang, Suhua
    Wang, Xiaogang
    PLOS ONE, 2018, 13 (03):
  • [33] The measurement of anterior chamber depth and axial length with the IOLMaster compared with contact ultrasonic axial scan
    Bai, Quan-Hao
    Wang, Jun-Li
    Wang, Qing-Qiang
    Yan, Qi-Chang
    Zhang, Jin-Song
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2008, 1 (02) : 151 - 154
  • [34] Cycloplegic Anterior Chamber Depth Measurements Using Anterior Segment Optical Coherence Tomography (VisanteTM)
    Aschbrenner, M. W.
    Moss, H. B.
    Lyles, G. W.
    Cohen, K. L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [35] Assessing the accuracy of Orbscan II post-LASIK: apparent keratectasia is paradoxically associated with anterior chamber depth reduction in successful procedures
    Cairns, G
    Ormonde, SE
    Gray, T
    Hadden, OB
    Morris, T
    Ring, P
    McGhee, CNJ
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (02): : 147 - 152
  • [36] Comparison of horizontal corneal diameter measurements using Galilei, EyeSys and Orbscan II systems
    Salouti, Ramin
    Nowroozzadeh, Mohammad H.
    Zamani, Mohammad
    Ghoreyshi, Maryam
    Salouti, Rosa
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (05) : 429 - 433
  • [37] Change in intraocular pressure following cataract extraction is unrelated to preoperative anterior chamber depth as measured by an IOLMaster
    Jacobs, Emily
    Tannen, Bradford Laurence
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [38] Anterior Segment Measurements Using Pentacam and Orbscan II 1 to 5 Years After Refractive Surgery
    Kim, Sun Woong
    Sun, Hae Jung
    Chang, Jee Ho
    Kim, Eung Kweon
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (12) : 1091 - 1097
  • [39] Magnetic resonance imaging and Orbscan assessment of the anterior chamber
    Fea, AM
    Annetta, F
    Cirillo, S
    Campanella, D
    De Giuseppe, M
    Regge, D
    Grignolo, FM
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09): : 1713 - 1718
  • [40] Comparison of Anterior Chamber Depth of Normal and Keratoconus Eyes Using Scheimpflug Photography
    Edmonds, Charles R.
    Wung, Shu-Fen
    Pemberton, Bart
    Surrett, Steven
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (03): : 120 - 122