Variability of electrode positions using electrode caps

被引:19
|
作者
Atcherson, Samuel R.
Gould, Herbert Jay
Pousson, Monique A.
Prout, Tina M.
机构
[1] Univ S Dakota, Auditory Neurosci Lab, Vermillion, SD 57069 USA
[2] Univ Memphis, Auditory Electrophysiol Lab, Memphis, TN 38152 USA
[3] Univ No Colorado, Audiol & Speech Language Sci, Greeley, CO 80639 USA
关键词
electrode caps; variability; scalp measurements; 10-20; system;
D O I
10.1007/s10548-007-0036-z
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We investigated the variability of electrode positions for a multi-channel, custom electrode cap placed onto participants' heads without taking scalp measurements. The electrode positions were digitized in a three-dimensional space for 10 young adult participants on three separate occasions. Positional variability was determined for 15 selected electrodes within the three-dimensional preauricular-nasion (PAN) coordinate system and from this system, angular coordinate variability was also determined. The standard deviations of the 15 selected electrodes ranged from 3.0 to 12.7 mm in the PAN system. These data resulted in a variability of 2.0 degrees to 10.4 degrees among the angular coordinates. The measurements indicated slightly greater variability of electrode positions compared to studies when electrodes were placed using scalp measurements. The implication of this study is that the use of electrode caps may not be appropriate when electroencephalographic (EEG) or evoked potential (EP) techniques depend on accurate electrode placement. Additionally, if a longitudinal study is performed, electrode locations should be checked to ensure that they conform with previous sessions.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 50 条
  • [31] IS NIPPLE PREFERRED LANDMARK FOR SELECTING CHEST ELECTRODE POSITIONS IN INFANTS
    WALSH, SZ
    JOURNAL OF PEDIATRICS, 1974, 84 (01): : 101 - 102
  • [32] THE EFFECT OF MODIFIED LIMB ELECTRODE POSITIONS ON ELECTROCARDIOGRAPHIC WAVE AMPLITUDES
    RAUTAHARJU, PM
    PRINEAS, RJ
    CROW, RS
    SEALE, D
    FURBERG, C
    JOURNAL OF ELECTROCARDIOLOGY, 1980, 13 (02) : 109 - 113
  • [33] Optimal electrode positions for ABR-reording in pedaudiology.
    Pethe, J
    Begall, K
    Muhler, R
    Smukalla, K
    von Specht, H
    LARYNGO-RHINO-OTOLOGIE, 1998, 77 (03) : 131 - 135
  • [34] CMAP VARIABILITY AS A FUNCTION OF ELECTRODE SITE AND SIZE
    VANDIJK, JG
    TJONATSIEN, A
    VANDERKAMP, W
    MUSCLE & NERVE, 1995, 18 (01) : 68 - 73
  • [35] Use of modified electrode caps for surface quality welds in resistance spot welding
    Mazur, Wojciech
    Kyriakopoulos, Alex
    Bott, Nicholas
    West, David
    JOURNAL OF MANUFACTURING PROCESSES, 2016, 22 : 60 - 73
  • [36] GLUCOSE ELECTRODE USING GLASSY-CARBON AS BASE ELECTRODE
    MATSUMOTO, K
    YOSHIOKA, S
    NOMURA, T
    OSAJIMA, Y
    SCIENCE BULLETIN OF THE FACULTY OF AGRICULTURE KYUSHU UNIVERSITY, 1980, 34 (3-4): : 115 - 121
  • [37] THE ELECTRODE CONCENTRATION CELLS USING A GAS-DIFFUSION ELECTRODE
    FURUYA, N
    KAWAHARA, T
    DENKI KAGAKU, 1988, 56 (06): : 449 - 450
  • [38] LIPOSOME IMMUNO-ELECTRODE USING GLUCOSE ENZYME ELECTRODE
    UMEZAWA, Y
    SOFUE, S
    TAKAMOTO, Y
    DENKI KAGAKU, 1982, 50 (01): : 107 - 108
  • [39] Time-resolved optical emission imaging of an atmospheric plasma jet for different electrode positions with a constant electrode gap
    Maletic, D.
    Puac, N.
    Selakovic, N.
    Lazovic, S.
    Malovic, G.
    Dordevic, A.
    Petrovic, Z. Lj
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2015, 24 (02):
  • [40] Effect of electrode resistance for acoustic coupler using quadrature electrode
    Shiba, T
    Fujita, Y
    Kondo, S
    Hamasaki, J
    Ide, M
    Ogawa, S
    Oda, K
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 251 - 254