Variability of electrode positions using electrode caps

被引:19
|
作者
Atcherson, Samuel R.
Gould, Herbert Jay
Pousson, Monique A.
Prout, Tina M.
机构
[1] Univ S Dakota, Auditory Neurosci Lab, Vermillion, SD 57069 USA
[2] Univ Memphis, Auditory Electrophysiol Lab, Memphis, TN 38152 USA
[3] Univ No Colorado, Audiol & Speech Language Sci, Greeley, CO 80639 USA
关键词
electrode caps; variability; scalp measurements; 10-20; system;
D O I
10.1007/s10548-007-0036-z
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We investigated the variability of electrode positions for a multi-channel, custom electrode cap placed onto participants' heads without taking scalp measurements. The electrode positions were digitized in a three-dimensional space for 10 young adult participants on three separate occasions. Positional variability was determined for 15 selected electrodes within the three-dimensional preauricular-nasion (PAN) coordinate system and from this system, angular coordinate variability was also determined. The standard deviations of the 15 selected electrodes ranged from 3.0 to 12.7 mm in the PAN system. These data resulted in a variability of 2.0 degrees to 10.4 degrees among the angular coordinates. The measurements indicated slightly greater variability of electrode positions compared to studies when electrodes were placed using scalp measurements. The implication of this study is that the use of electrode caps may not be appropriate when electroencephalographic (EEG) or evoked potential (EP) techniques depend on accurate electrode placement. Additionally, if a longitudinal study is performed, electrode locations should be checked to ensure that they conform with previous sessions.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 50 条
  • [21] Dynamic detection of vacuum-switch electrode positions
    Dong, Huajun
    Kong, Yihan
    Zang, Kan
    Liu, Chang
    Guo, Fangzhun
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2014, 34 (12): : 1310 - 1314
  • [22] Randomised comparison of electrode positions for cardioversion of atrial fibrillation
    Mathew, TP
    Moore, A
    McIntyre, M
    Harbinson, MT
    Campbell, NPS
    Adgey, AAJ
    Dalzell, GWN
    HEART, 1999, 81 (06) : 576 - 579
  • [23] Supraorbital and d'Elia electrode positions in unilateral ECT?
    Pridmore, S
    Rybak, M
    JOURNAL OF ECT, 1999, 15 (02) : 170 - 171
  • [24] Algorithmic localization of high-density EEG electrode positions using motion capture
    Hirth, Lauren N.
    Stanley, Christopher J.
    Damiano, Diane L.
    Bulea, Thomas C.
    JOURNAL OF NEUROSCIENCE METHODS, 2020, 346
  • [25] REDUCED ELECTRODE CONSUMPTION USING COMPOSITE ELECTRODE SYSTEM
    PUGH, RW
    REVUE DE METALLURGIE-CAHIERS D INFORMATIONS TECHNIQUES, 1982, 79 (04): : 363 - 370
  • [26] Simulation and evaluation of float glass furnace with different electrode positions
    Han, Jianjun
    Li, Luyao
    Wang, Jing
    Chen, Shuyong
    Liu, Chao
    Li, Congyun
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2022, 105 (12) : 7097 - 7110
  • [27] EEG ELECTRODE POSITIONS OUTSIDE THE HAIRLINE TO MONITOR SLEEP IN MAN
    DYSON, RJ
    THORNTON, C
    DORE, CJ
    SLEEP, 1984, 7 (02) : 180 - 188
  • [28] Optimizing Electrode Positions in 2-D Electrical Impedance Tomography Using Deep Learning
    Smyl, Danny
    Liu, Dong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (09) : 6030 - 6044
  • [29] Estimation of Positions and Orientations of Activated Muscle Fibers with Electrode Array
    Wang, Mian
    Ma, Shihan
    Geng, Zihang
    Chen, Chen
    Sheng, Xinjun
    Zhu, Xiangyang
    2021 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (IEEE BIOCAS 2021), 2021,
  • [30] Calculation of cerebral state index from different electrode positions
    Paprotny, S.
    Kreuzer, M.
    Hock, A.
    Kochs, E. F.
    Schneider, G.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (06) : 872P - 873P