In vitro bacterial adherence to hydrogel and poly(methyl methacrylate) intraocular lenses

被引:21
|
作者
Ng, EWM [1 ]
Barrett, GD [1 ]
Bowman, R [1 ]
机构
[1] LIONS EYE INST,PERTH,WA 6009,AUSTRALIA
关键词
D O I
10.1016/S0886-3350(96)80093-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the in vitro adherence of Staphylococcus epidermidis to poly(hydroxyethyl methacrylate) (polyHEMA) or hydrogel intraocular lenses (IOLs) and poly(methyl methacrylate) (PMMA) IOLs. Setting: Lions Eye Institute, Perth, Western Australia. Methods: One-piece hydrogel lenses and one-piece PMMA lenses were suspended for 60 minutes in standardized suspensions of a well-characterized strain of S. epidermidis and then sonicated in a known quantity of balanced salt solution to remove the adherent bacteria. Quantitative cultures of the sonicates were performed and the results analyzed statistically. Results: The mean bacterial adherence of S. epidermidis to the PMMA IOLs (58,400 CFU) was more than 20 times greater than that to the hydrogel IOLs (1953 CFU). The difference was statistically significant (P < .001). Conclusions: Adherence of S. epidermidis to hydrogel IOLs is significantly lower than to PMMA IOLs. This suggests that the risk of postoperative endophthalmitis after cataract extraction and IOL implantation may be lower with the use of hydrogel IOLs.
引用
收藏
页码:1331 / 1335
页数:5
相关论文
共 50 条
  • [41] COMPARISON OF THE POSTOPERATIVE INFLAMMATORY RESPONSE IN THE NORMAL EYE WITH HEPARIN-SURFACE-MODIFIED AND POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES
    SHAH, SM
    SPALTON, DJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (05): : 579 - 585
  • [42] Biocompatibility of poly(methyl methacrylate), silicone, and AcrySof intraocular lenses: Randomized comparison of the cellular reaction on the anterior lens surface
    Hollick, EJ
    Spalton, DJ
    Ursell, PG
    Pande, MV
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (03): : 361 - 366
  • [43] Silicone versus poly(methyl methacrylate) lenses in combined phacoemulsification and trabeculectomy
    Kosmin, AS
    Wishart, PK
    Ridges, PJG
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (01): : 97 - 105
  • [44] Durability of Poly(Methyl Methacrylate) Lenses Used in Concentrating Photovoltaic Modules
    Miller, David C.
    Gedvilas, Lynn M.
    To, Bobby
    Kennedy, Cheryl E.
    Kurtz, Sarah R.
    RELIABILITY OF PHOTOVOLTAIC CELLS, MODULES, COMPONENTS, AND SYSTEMS III, 2010, 7773
  • [45] BICONVEX INTRAOCULAR LENSES AND ND-YAG CAPSULOTOMY - EXPERIMENTAL COMPARISON OF SURFACE DAMAGE WITH DIFFERENT POLY(METHYL METHACRYLATE) FORMULATIONS
    DOWNING, JE
    ALBERHASKY, MT
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (06): : 732 - 736
  • [46] Bacterial Adherence and Structural Organization of Staphylococcus Epidermidis Biofilm on Different Types of Intraocular Lenses Under in vitro Flow Conditions
    Baillif, S. A.
    Renaud, F.
    Hartmann, D. J.
    Kodjikian, L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [47] KERATOMETRIC CYLINDER AND VISUAL PERFORMANCE FOLLOWING PHACOEMULSIFICATION AND IMPLANTATION WITH SILICONE SMALL-INCISION OR POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES
    BRINT, SF
    OSTRICK, DM
    BRYAN, JE
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (01): : 32 - 36
  • [48] Inflammatory cell adhesion and surface defects on heparin-surface-modified poly(methyl methacrylate) intraocular lenses in diabetic patients
    Tognetto, D
    Ravalico, G
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (02): : 239 - 244
  • [49] ANOTHER LOOK AT HYDROGEL INTRAOCULAR LENSES
    OBSTBAUM, SA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (01): : 1 - 1
  • [50] BACTERIAL ADHESION TO INTRAOCULAR LENSES
    DILLY, PN
    SELLORS, PJH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (03): : 317 - 320