In vitro bacterial adherence to hydrogel and poly(methyl methacrylate) intraocular lenses

被引:21
|
作者
Ng, EWM [1 ]
Barrett, GD [1 ]
Bowman, R [1 ]
机构
[1] LIONS EYE INST,PERTH,WA 6009,AUSTRALIA
关键词
D O I
10.1016/S0886-3350(96)80093-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the in vitro adherence of Staphylococcus epidermidis to poly(hydroxyethyl methacrylate) (polyHEMA) or hydrogel intraocular lenses (IOLs) and poly(methyl methacrylate) (PMMA) IOLs. Setting: Lions Eye Institute, Perth, Western Australia. Methods: One-piece hydrogel lenses and one-piece PMMA lenses were suspended for 60 minutes in standardized suspensions of a well-characterized strain of S. epidermidis and then sonicated in a known quantity of balanced salt solution to remove the adherent bacteria. Quantitative cultures of the sonicates were performed and the results analyzed statistically. Results: The mean bacterial adherence of S. epidermidis to the PMMA IOLs (58,400 CFU) was more than 20 times greater than that to the hydrogel IOLs (1953 CFU). The difference was statistically significant (P < .001). Conclusions: Adherence of S. epidermidis to hydrogel IOLs is significantly lower than to PMMA IOLs. This suggests that the risk of postoperative endophthalmitis after cataract extraction and IOL implantation may be lower with the use of hydrogel IOLs.
引用
收藏
页码:1331 / 1335
页数:5
相关论文
共 50 条
  • [21] In vivo study of cell reactions on poly(methyl methacrylate) intraocular lenses with different surface properties
    Amon, M
    Menapace, R
    Radax, U
    Freyler, H
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 : 825 - 829
  • [22] Endothelial damage caused by uncoated and fluorocarbon-coated poly(methyl methacrylate) intraocular lenses
    Werner, LP
    Legeais, JM
    Durand, J
    Savoldelli, M
    Legeay, G
    Renard, G
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (07): : 1013 - 1019
  • [23] POLYPROPYLENE HAPTICS INCREASE BACTERIAL ADHERENCE TO INTRAOCULAR LENSES
    RASKIN, E
    SPEAKER, M
    PELTONHENRION, K
    WONG, D
    MCCORMICK, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1420 - 1420
  • [24] INFLAMMATORY RESPONSE IN THE RABBIT EYE AFTER INTRAOCULAR IMPLANTATION WITH POLY(METHYL METHACRYLATE) AND HEPARIN SURFACE MODIFIED INTRAOCULAR LENSES
    LUNDGREN, B
    OCKLIND, A
    HOLST, A
    HARFSTRAND, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (01): : 65 - 70
  • [25] In vitro adherence of Pseudomonas aeruginosa to four intraocular lenses
    Gabriel, MM
    Ahearn, DG
    Chan, KY
    Patel, AS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (01): : 124 - 129
  • [26] THE BINKHORST MEDAL LECTURE - BIOLOGIC RELATIONSHIP BETWEEN POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES AND UVEAL TISSUE
    OBSTBAUM, SA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (03): : 219 - 231
  • [27] Capsule contraction after continuous curvilinear capsulorhexis: Poly(methyl methacrylate) versus silicone intraocular lenses
    Cochener, B
    Jacq, PL
    Colin, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (10): : 1362 - 1369
  • [28] Straight-entrance, sclerocorneal valve incision with horizontal sutures for poly(methyl methacrylate) intraocular lenses
    Menapace, R
    Vass, C
    Radax, U
    Strenn, K
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (07): : 882 - 890
  • [29] Posterior capsule opacification after phacoemulsification:: Foldable acrylic versus poly(methyl methacrylate) intraocular lenses
    Oner, FH
    Gunenc, Ü
    Ferliel, ST
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (05): : 722 - 726
  • [30] Simulation and fabrication of poly methyl methacrylate infrared lenses
    Tsui, Chun-Chao
    Su, Guo-Dung J.
    INFRARED SENSORS, DEVICES, AND APPLICATIONS AND SINGLE PHOTON IMAGING II, 2011, 8155