In vitro bacterial adherence to hydrogel and poly(methyl methacrylate) intraocular lenses

被引:21
|
作者
Ng, EWM [1 ]
Barrett, GD [1 ]
Bowman, R [1 ]
机构
[1] LIONS EYE INST,PERTH,WA 6009,AUSTRALIA
关键词
D O I
10.1016/S0886-3350(96)80093-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the in vitro adherence of Staphylococcus epidermidis to poly(hydroxyethyl methacrylate) (polyHEMA) or hydrogel intraocular lenses (IOLs) and poly(methyl methacrylate) (PMMA) IOLs. Setting: Lions Eye Institute, Perth, Western Australia. Methods: One-piece hydrogel lenses and one-piece PMMA lenses were suspended for 60 minutes in standardized suspensions of a well-characterized strain of S. epidermidis and then sonicated in a known quantity of balanced salt solution to remove the adherent bacteria. Quantitative cultures of the sonicates were performed and the results analyzed statistically. Results: The mean bacterial adherence of S. epidermidis to the PMMA IOLs (58,400 CFU) was more than 20 times greater than that to the hydrogel IOLs (1953 CFU). The difference was statistically significant (P < .001). Conclusions: Adherence of S. epidermidis to hydrogel IOLs is significantly lower than to PMMA IOLs. This suggests that the risk of postoperative endophthalmitis after cataract extraction and IOL implantation may be lower with the use of hydrogel IOLs.
引用
收藏
页码:1331 / 1335
页数:5
相关论文
共 50 条
  • [1] Effect of vancomycin on Staphylococcus epidermidis adherence to poly(methyl methacrylate) intraocular lenses
    Das, T
    Sharma, S
    Muralidhar, AV
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04): : 703 - 708
  • [2] OPTICAL DESIGN OF POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES
    ATCHISON, DA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (02): : 178 - 187
  • [3] Bacterial adherence on PMMA intraocular lenses - A in vitro study
    Schnitzler, EM
    Fries, U
    Schafer, V
    Stenger, N
    Ohrloff, C
    Brade, V
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 893 - 893
  • [4] Contrast sensitivity with silicone and poly(methyl methacrylate) intraocular lenses
    Johansen, J
    DamJohansen, M
    Olsen, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (07): : 1085 - 1088
  • [5] In vitro adherence of Staphylococcus epidermidis to polymethyl methacrylate and acrysof intraocular lenses
    Pinna, A
    Zanetti, S
    Sechi, LA
    Usai, D
    Falchi, MP
    Carta, F
    OPHTHALMOLOGY, 2000, 107 (06) : 1042 - 1046
  • [6] Cellular reaction on the anterior surface of poly(methyl methacrylate) intraocular lenses
    Pande, MV
    Spalton, DJ
    KerrMuir, MG
    Marshall, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 : 811 - 817
  • [7] COMPLEMENT ACTIVATION BY SURFACE MODIFIED POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES
    KOCHOUNIAN, HH
    MAXWELL, WA
    GUPTA, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (02): : 139 - 142
  • [8] Position of poly(methyl methacrylate) and silicone intraocular lenses after phacoemulsification
    Wang, MC
    Woung, LC
    Hu, CY
    Kuo, HC
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (12): : 1652 - 1657
  • [9] The effect of ionising radiation on poly(methyl methacrylate) used in intraocular lenses
    Pratt, C. M.
    Barton, S.
    McGonigle, E.
    Kishi, M.
    Foot, P. J. S.
    POLYMER DEGRADATION AND STABILITY, 2006, 91 (10) : 2315 - 2317
  • [10] In vitro study of antibiotic effect on bacterial adherence to acrylic intraocular lenses
    Gaál, V
    Kilár, F
    Acs, B
    Szijjártó, Z
    Kocsis, B
    Kustos, D
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2005, 45 (3-4) : 125 - 130