Physics settings for using the Geant4 toolkit in proton therapy

被引:165
|
作者
Jarlskog, Christina Zacharatou [1 ,2 ]
Paganetti, Harald [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
关键词
Geant4; Monte Carlo; physics validation; proton therapy;
D O I
10.1109/TNS.2008.922816
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We simulated electromagnetic and nuclear processes induced by clinical proton beams in order to select the physics setting for the 8.1 version of the Geant4 toolkit. A modular physics list was constructed allowing for alternative processes and models to be invoked in the simulations. We validated the Monte Carlo by means of measured depth-dose distributions in water for 86 MeV and 209 MeV beams and measured longitudinal charge profiles in a stack of polyethylene absorbers (multilayer Faraday cup) for a 160 MeV beam. Best agreement between simulation and measurement was found for the standard electromagnetic and binary cascade models of Geant4.
引用
收藏
页码:1018 / 1025
页数:8
相关论文
共 50 条
  • [31] Recent Improvements in the Geant4 Monte Carlo Simulation Toolkit for Medical Physics Applications
    Perl, J.
    Faddegon, B.
    Paganetti, H.
    MEDICAL PHYSICS, 2008, 35 (06) : 2803 - +
  • [32] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 896 - 901
  • [33] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2138 - 2142
  • [34] Validation of Geant4 hadronic physics
    Beringer, J
    Folger, G
    Gianotti, F
    Ribon, A
    Wellisch, JP
    Barberis, D
    Cervetto, M
    Osculati, B
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 494 - 498
  • [35] GEANT4 Physics Lists for HEP
    Apostolakis, J.
    Folger, G.
    Grichine, V.
    Howard, A.
    Ivanchenko, V.
    Kosov, M.
    Ribon, A.
    Uzhinsky, V.
    Wright, D. H.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 108 - +
  • [36] A revision of soft proton scattering at grazing incidence and its implementation in the geant4 toolkit
    Alejandro Guzmán
    Emanuele Perinati
    Sebastian Diebold
    Chris Tenzer
    Andrea Santangelo
    Experimental Astronomy, 2017, 44 : 401 - 411
  • [37] A revision of soft proton scattering at grazing incidence and its implementation in the geant4 toolkit
    Guzman, Alejandro
    Perinati, Emanuele
    Diebold, Sebastian
    Tenzer, Chris
    Santangelo, Andrea
    EXPERIMENTAL ASTRONOMY, 2017, 44 (03) : 401 - 411
  • [38] Studies of the radiation environment on the Mars surface using the Geant4 toolkit
    Chen, Jun-Liang
    Yun, Su-Jun
    Dong, Tie-Kuang
    Ren, Zhong-Zhou
    Zhang, Xiao-Ping
    NUCLEAR SCIENCE AND TECHNIQUES, 2022, 33 (01)
  • [39] Studies of the radiation environment on the Mars surface using the Geant4 toolkit
    Jun-Liang Chen
    Su-Jun Yun
    Tie-Kuang Dong
    Zhong-Zhou Ren
    Xiao-Ping Zhang
    Nuclear Science and Techniques, 2022, 33
  • [40] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit REPLY
    Cai, Zhongli
    Pignol, Jean-Philippe
    Chan, Conrad
    Reilly, Raymond M.