Physics settings for using the Geant4 toolkit in proton therapy

被引:165
|
作者
Jarlskog, Christina Zacharatou [1 ,2 ]
Paganetti, Harald [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
关键词
Geant4; Monte Carlo; physics validation; proton therapy;
D O I
10.1109/TNS.2008.922816
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We simulated electromagnetic and nuclear processes induced by clinical proton beams in order to select the physics setting for the 8.1 version of the Geant4 toolkit. A modular physics list was constructed allowing for alternative processes and models to be invoked in the simulations. We validated the Monte Carlo by means of measured depth-dose distributions in water for 86 MeV and 209 MeV beams and measured longitudinal charge profiles in a stack of polyethylene absorbers (multilayer Faraday cup) for a 160 MeV beam. Best agreement between simulation and measurement was found for the standard electromagnetic and binary cascade models of Geant4.
引用
收藏
页码:1018 / 1025
页数:8
相关论文
共 50 条
  • [21] The Geant4 simulation toolkit and its low energy electromagnetic physics package
    Chauvie, S
    Ivanchenko, V
    Longo, F
    Santin, G
    Nieminen, P
    Pia, MG
    MEDICAL PHYSICS, 2002, 29 (06) : 1231 - 1231
  • [22] Optimization of GEANT4 settings for Proton Pencil Beam Scanning simulations using GATE
    Grevillot, Loic
    Frisson, Thibault
    Zahra, Nabil
    Bertrand, Damien
    Stichelbaut, Frederic
    Freud, Nicolas
    Sarrut, David
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (20): : 3295 - 3305
  • [23] A Toolkit to Study Sensitivity of the Geant4 Predictions to the Variations of the Physics Model Parameters
    Fields, Laura
    Genser, Krzysztof
    Hatcher, Robert
    Kelsey, Michael
    Perdue, Gabriel
    Wenzel, Hans
    Wright, Dennis H.
    Yarba, Julia
    18TH INTERNATIONAL WORKSHOP ON ADVANCED COMPUTING AND ANALYSIS TECHNIQUES IN PHYSICS RESEARCH (ACAT2017), 2018, 1085
  • [24] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit
    Freudenberg, Robert
    Kotzerke, Jorg
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) : 1488 - 1489
  • [25] Impacts of Geant4 hadronic physics models on secondary particle productions in proton therapy simulations
    Lai, Pham Thi Cam
    Hai, Vo Hong
    Phuc, Nguyen Tri Toan
    RADIATION PHYSICS AND CHEMISTRY, 2025, 229
  • [26] The Geant4 object oriented simulation toolkit
    Pia, MG
    HIGH ENERGY PHYSICS 99, PROCEEDINGS, 2000, : 1024 - 1026
  • [27] Space applications of the Geant4 simulation toolkit
    Daly, E
    Evans, H
    Lei, F
    Longo, F
    Magni, S
    Nartallo, R
    Nieminen, P
    Pia, MG
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 401 - 406
  • [28] Validation of Geant4 Physics Models for the Simulation of the Proton Bragg Peak
    Cirrone, G. A. P.
    Cuttone, G.
    Di Rosa, F.
    Guatelli, S.
    Mascialino, B.
    Pia, M. G.
    Russo, G.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 788 - 792
  • [29] Geant4 toolkit for simulation of HEP experiments
    Ivanchenko, VN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 502 (2-3): : 666 - 668
  • [30] A Study on Multiplex Proton Imaging Using GEANT4
    Aso, Tsukasa
    Kawashima, Kazuki
    Nishio, Teiji
    Lee, Se Byeong
    Sasaki, Takashi
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1717 - 1719