Quantitative Mass Spectrometry Combined with Separation and Enrichment of Phosphopeptides by Titania Coated Magnetic Mesoporous Silica Microspheres for Screening of Protein Kinase Inhibitors

被引:37
|
作者
Ji, Liyun [1 ]
Wu, Jian-Hong [2 ]
Luo, Qun [1 ]
Li, Xianchan [1 ]
Zheng, Wei [1 ]
Zhai, Guijin [1 ]
Wang, Fuyi [1 ]
Lu, Shuang [1 ]
Feng, Yu-Qi [2 ]
Liu, Jianan [1 ]
Xiong, Shaoxiang [1 ]
机构
[1] Chinese Acad Sci, Bening Natl Lab Mol Sci, CAS Key Lab Analyt Chem Living Biosyst, Beijing Ctr Mass Spectrometry,Inst Chem, Beijing 100190, Peoples R China
[2] Wuhan Univ, Coll Chem & Mol Sci, Wuhan 430072, Peoples R China
关键词
MALDI-TOF-MS; DEPOSITED CAPILLARY COLUMN; LARGE-SCALE ANALYSIS; PHOSPHORYLATED PEPTIDES; AFFINITY-CHROMATOGRAPHY; ENZYME-ACTIVITIES; DESORPTION/IONIZATION; PHOSPHOPROTEOMICS; PROTEOMICS; MATRIX;
D O I
10.1021/ac202897u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe herein the development of a matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry (MALDI-TOF-MS) approach for screening of protein kinase inhibitors (PKIs). MS quantification of phosphopeptides, the kinase-catalyzed products of nonphosphorylated substrates, is a great challenge due to the ion suppression effect of highly abundant nonphosphorylated peptides in enzymatic reaction mixtures. To address this issue, a novel type of titania coated magnetic hollow mesoporous silica spheres (TiO2/MHMSS) material was fabricated for capturing phosphopeptides from the enzymatic reaction mixtures prior to MS analysis. Under optimized conditions, even in the presence of 1000-fold of a substrate peptide of tyrosine kinase epidermal growth factor receptor (EGFR), the phosphorylated substrates at the femtomole level can be detected with high accuracy and reproducibility. With a synthetic nonisotopic labeled phosphopeptide, of which the sequence is similar to that of the phosphorylated substrate, as the internal standard, the MS signal ratio of the phosphorylated substrate to the standard is linearly correlated with the molar ratio of the two phosphopeptides in peptide mixtures over the range of 0.1 to 4 with r(2) being 0.99. The IC50 values of three EGFR inhibitors synthesized in our laboratory were then determined, and the results are consistent with those determined by an enzyme-linked immunosorbent assay (ELISA). The developed method is sensitive, cost/time-effective, and operationally simple and does not require isotope/radioative-labeling, providing an ideal alterative for screening of PKIs as therapeutic agents.
引用
收藏
页码:2284 / 2291
页数:8
相关论文
共 32 条
  • [31] Rapidly and accurately screening histidine decarboxylase inhibitors from Radix Paeoniae alba using ultrafiltration-high performance liquid chromatography/mass spectrometry combined with enzyme channel blocking and directional enrichment technique
    Hu, Guizhou
    Wang, Lu
    Li, Xinqi
    Qi, Jin
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1693
  • [32] Titanium dioxide-coated core-shell silica microspheres-based solid-phase extraction combined with sheathless capillary electrophoresis-mass spectrometry for analysis of glyphosate, glufosinate and their metabolites in baby foods
    Liu, Jianing
    Feng, Wenxia
    Tian, Miaomiao
    Hu, Lihuan
    Qu, Qishu
    Yang, Li
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1659