共 32 条
Quantitative Mass Spectrometry Combined with Separation and Enrichment of Phosphopeptides by Titania Coated Magnetic Mesoporous Silica Microspheres for Screening of Protein Kinase Inhibitors
被引:37
|作者:
Ji, Liyun
[1
]
Wu, Jian-Hong
[2
]
Luo, Qun
[1
]
Li, Xianchan
[1
]
Zheng, Wei
[1
]
Zhai, Guijin
[1
]
Wang, Fuyi
[1
]
Lu, Shuang
[1
]
Feng, Yu-Qi
[2
]
Liu, Jianan
[1
]
Xiong, Shaoxiang
[1
]
机构:
[1] Chinese Acad Sci, Bening Natl Lab Mol Sci, CAS Key Lab Analyt Chem Living Biosyst, Beijing Ctr Mass Spectrometry,Inst Chem, Beijing 100190, Peoples R China
[2] Wuhan Univ, Coll Chem & Mol Sci, Wuhan 430072, Peoples R China
关键词:
MALDI-TOF-MS;
DEPOSITED CAPILLARY COLUMN;
LARGE-SCALE ANALYSIS;
PHOSPHORYLATED PEPTIDES;
AFFINITY-CHROMATOGRAPHY;
ENZYME-ACTIVITIES;
DESORPTION/IONIZATION;
PHOSPHOPROTEOMICS;
PROTEOMICS;
MATRIX;
D O I:
10.1021/ac202897u
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
We describe herein the development of a matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry (MALDI-TOF-MS) approach for screening of protein kinase inhibitors (PKIs). MS quantification of phosphopeptides, the kinase-catalyzed products of nonphosphorylated substrates, is a great challenge due to the ion suppression effect of highly abundant nonphosphorylated peptides in enzymatic reaction mixtures. To address this issue, a novel type of titania coated magnetic hollow mesoporous silica spheres (TiO2/MHMSS) material was fabricated for capturing phosphopeptides from the enzymatic reaction mixtures prior to MS analysis. Under optimized conditions, even in the presence of 1000-fold of a substrate peptide of tyrosine kinase epidermal growth factor receptor (EGFR), the phosphorylated substrates at the femtomole level can be detected with high accuracy and reproducibility. With a synthetic nonisotopic labeled phosphopeptide, of which the sequence is similar to that of the phosphorylated substrate, as the internal standard, the MS signal ratio of the phosphorylated substrate to the standard is linearly correlated with the molar ratio of the two phosphopeptides in peptide mixtures over the range of 0.1 to 4 with r(2) being 0.99. The IC50 values of three EGFR inhibitors synthesized in our laboratory were then determined, and the results are consistent with those determined by an enzyme-linked immunosorbent assay (ELISA). The developed method is sensitive, cost/time-effective, and operationally simple and does not require isotope/radioative-labeling, providing an ideal alterative for screening of PKIs as therapeutic agents.
引用
收藏
页码:2284 / 2291
页数:8
相关论文