Quantitative Mass Spectrometry Combined with Separation and Enrichment of Phosphopeptides by Titania Coated Magnetic Mesoporous Silica Microspheres for Screening of Protein Kinase Inhibitors

被引:37
|
作者
Ji, Liyun [1 ]
Wu, Jian-Hong [2 ]
Luo, Qun [1 ]
Li, Xianchan [1 ]
Zheng, Wei [1 ]
Zhai, Guijin [1 ]
Wang, Fuyi [1 ]
Lu, Shuang [1 ]
Feng, Yu-Qi [2 ]
Liu, Jianan [1 ]
Xiong, Shaoxiang [1 ]
机构
[1] Chinese Acad Sci, Bening Natl Lab Mol Sci, CAS Key Lab Analyt Chem Living Biosyst, Beijing Ctr Mass Spectrometry,Inst Chem, Beijing 100190, Peoples R China
[2] Wuhan Univ, Coll Chem & Mol Sci, Wuhan 430072, Peoples R China
关键词
MALDI-TOF-MS; DEPOSITED CAPILLARY COLUMN; LARGE-SCALE ANALYSIS; PHOSPHORYLATED PEPTIDES; AFFINITY-CHROMATOGRAPHY; ENZYME-ACTIVITIES; DESORPTION/IONIZATION; PHOSPHOPROTEOMICS; PROTEOMICS; MATRIX;
D O I
10.1021/ac202897u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe herein the development of a matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry (MALDI-TOF-MS) approach for screening of protein kinase inhibitors (PKIs). MS quantification of phosphopeptides, the kinase-catalyzed products of nonphosphorylated substrates, is a great challenge due to the ion suppression effect of highly abundant nonphosphorylated peptides in enzymatic reaction mixtures. To address this issue, a novel type of titania coated magnetic hollow mesoporous silica spheres (TiO2/MHMSS) material was fabricated for capturing phosphopeptides from the enzymatic reaction mixtures prior to MS analysis. Under optimized conditions, even in the presence of 1000-fold of a substrate peptide of tyrosine kinase epidermal growth factor receptor (EGFR), the phosphorylated substrates at the femtomole level can be detected with high accuracy and reproducibility. With a synthetic nonisotopic labeled phosphopeptide, of which the sequence is similar to that of the phosphorylated substrate, as the internal standard, the MS signal ratio of the phosphorylated substrate to the standard is linearly correlated with the molar ratio of the two phosphopeptides in peptide mixtures over the range of 0.1 to 4 with r(2) being 0.99. The IC50 values of three EGFR inhibitors synthesized in our laboratory were then determined, and the results are consistent with those determined by an enzyme-linked immunosorbent assay (ELISA). The developed method is sensitive, cost/time-effective, and operationally simple and does not require isotope/radioative-labeling, providing an ideal alterative for screening of PKIs as therapeutic agents.
引用
收藏
页码:2284 / 2291
页数:8
相关论文
共 32 条
  • [11] Determination of organochlorine pesticide residues in food by polystyrene coated silica magnetic microspheres combined with gas chromatography-mass spectrometry
    Wang, Jinxin
    Shi, Yilan
    Pan, Yuping
    Qiu, Qianying
    Ye, Qinghua
    Cheng, Xiaohong
    Yang, Qinghua
    Yu, Chunmei
    MICROCHEMICAL JOURNAL, 2024, 207
  • [12] Screening of protein kinase inhibitors in natural extracts by capillary electrophoresis combined with liquid chromatography-tandem mass spectrometry
    Wang, Tongdan
    Zhang, Qianqian
    Zhang, Yanmei
    Kang, Jingwu
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1337 : 188 - 193
  • [13] Magnetic mesoporous carbon composites incorporating hydrophilic metallic nanoparticles for enrichment of phosphopeptides prior to their determination by MALDI-TOF mass spectrometry
    Lei Zhang
    Yangyang Gan
    Haofan Sun
    Bohao Yu
    Xiaofeng Jin
    Runsheng Zhang
    Weibing Zhang
    Lingyi Zhang
    Microchimica Acta, 2017, 184 : 547 - 555
  • [14] Magnetic mesoporous carbon composites incorporating hydrophilic metallic nanoparticles for enrichment of phosphopeptides prior to their determination by MALDI-TOF mass spectrometry
    Zhang, Lei
    Gan, Yangyang
    Sun, Haofan
    Yu, Bohao
    Jin, Xiaofeng
    Zhang, Runsheng
    Zhang, Weibing
    Zhang, Lingyi
    MICROCHIMICA ACTA, 2017, 184 (02) : 547 - 555
  • [15] Preparation of phenyl-functionalized magnetic mesoporous silica microspheres for the fast separation and selective enrichment of phenyl-containing peptides
    Li, Shihua
    Wang, Ling
    Zhao, Sen
    Lin, Jinjin
    Zheng, Jiangnan
    Lin, Zian
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (22) : 3954 - 3960
  • [16] Synthesis of magnetic microspheres with immobilized metal ions for enrichment and direct determination of phosphopeptides by matrix-assisted laser desorption ionization mass spectrometry
    Xu, Xiuqing
    Deng, Chunhui
    Gao, Mingxia
    Yu, Wenjia
    Yang, Pengyuan
    Zhang, Xiangmin
    ADVANCED MATERIALS, 2006, 18 (24) : 3289 - +
  • [17] On-Chip Mesoporous Functionalized Magnetic Microspheres for Protein Sequencing by Extended Bottom-up Mass Spectrometry
    Gasilova, Natalia
    Srzentic, Kristina
    Qiao, Liang
    Liu, Baohong
    Beck, Alain
    Tsybin, Yury O.
    Girault, Hubert H.
    ANALYTICAL CHEMISTRY, 2016, 88 (03) : 1775 - 1784
  • [18] Quantitative Analysis of Yeast Checkpoint Protein Kinase Activity by Combined Mass Spectrometry Enzyme Assays
    Hoch, N. C.
    Chen, E. S. -W.
    Tsai, M. -D.
    Heierhorst, J.
    PROTEOMICS IN BIOLOGY, PT B, 2017, 586 : 143 - 164
  • [19] Facile synthesis of Cu2+-modified mesoporous silica-coated magnetic graphene composite for enrichment of microcystin-LR followed by mass spectrometry analysis
    Liu, Shasha
    Deng, Chunhui
    Zhang, Xiangmin
    TALANTA, 2016, 154 : 183 - 189
  • [20] Screening the Inhibitors of Tau Protein Kinase 2 by Rapid Resolution Liquid Chromatogrophy-Mass Spectrometry
    Chen Ning
    Sun Yi
    Yue Hao
    Liu Shu-Ying
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2013, 34 (05): : 1111 - 1114