Evaluation of the Relation Between Preload Values and Pull-Out Force of the Cortical Screw Used in Bone Fracture

被引:1
|
作者
Celik, Talip [1 ]
机构
[1] Kocaeli Univ, Fac Technol, Dept Biomed Engn, TR-41380 Kocaeli, Turkey
关键词
preload; pull-out strength; cortical screw; fracture fixation; OSTEOPOROSIS; FIXATION; ELEMENT; STRENGTH; BEHAVIOR;
D O I
10.1115/1.4051186
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study aims to examine the relation between pull-out strength and preload values of the cortical screw used in bone fracture fixation. The research question is that "Does the pull-out strength of the cortical screw used in the bone fracture fixation change with the preload values of the screw change?". To perform this purpose, the finite element method was selected due to its ease to evaluate and calculate the stresses on the whole model. Models of a cortical screw, partial plate, and bone were created using the SolidWorks program. The material properties of the bone were selected orthotropic material type. The bone fixed on the distal and proximal ends. The pull-out forces were applied at the bottom of the plate. The screw that has been loaded ranges from 100 N-700 N as preload. The pull-out forces were determined 200-400-600 N as in the literature. The results show that the pull-out strength of the screw was changed when the preloaded values higher than 400 N. However, it was seen that the pull-out strength does not substantially change when the preload values were lower than 400 N. When the preload values were applied >= 500 N, the maximum von Mises stresses on the screw exceeded the critical strength of the screw material. In conclusion, the critical preload value was determined as 500 N for the optimum pull-out strength.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength
    Wichmann, Julian L.
    Booz, Christian
    Wesarg, Stefan
    Bauer, Ralf W.
    Kerl, J. Matthias
    Fischer, Sebastian
    Lehnert, Thomas
    Vogl, Thomas J.
    Khan, M. Fawad
    Kafchitsas, Konstantinos
    EUROPEAN RADIOLOGY, 2015, 25 (06) : 1714 - 1720
  • [42] PMMA-augmented SI screw: a biomechanical analysis of stiffness and pull-out force in a matched paired human cadaveric model
    Grechenig, Stephan
    Gaensslen, Axel
    Gueorguiev, Boyko
    Berner, Arne
    Mueller, Michael
    Nerlich, Michael
    Schmitz, Paul
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S125 - S128
  • [43] Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength
    Julian L. Wichmann
    Christian Booz
    Stefan Wesarg
    Ralf W. Bauer
    J. Matthias Kerl
    Sebastian Fischer
    Thomas Lehnert
    Thomas J. Vogl
    M. Fawad Khan
    Konstantinos Kafchitsas
    European Radiology, 2015, 25 : 1714 - 1720
  • [44] Is the pull-out force of the Meniscus Arrow in bone affected by the inward curling of the barbs during biodegradation? An in vitro study
    Wouters, Diederick B.
    Burgerhof, Johannes G. M.
    de Hosson, Jeff T. M.
    Bos, Rudolf R. M.
    MEDICAL SCIENCE MONITOR, 2009, 15 (04): : BR95 - BR98
  • [45] 3D pull-out finite element simulation of the pedicle screw-trabecular bone interface at strain rates
    Cetin, Ahmet
    Bircan, Durmus Ali
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2022, 236 (01) : 134 - 144
  • [46] Characterizing and predicting the relationship between translaminar fracture toughness and pull-out length distributions under distinct temperatures
    Yu, B.
    Katafiasz, T. J.
    Nguyen, S.
    Allegri, G.
    Finlayson, J.
    Greenhalgh, E. S.
    Pinho, S. T.
    Pimenta, S.
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2023, 381 (2240):
  • [47] Numerical and experimental study on the relationship between pull-out force and indentation depth of aviation wire crimp terminal
    Li, Pin
    Liu, Gongping
    Wang, Ping
    Huang, Guangwen
    Yu, Zhuonan
    Xiu, Hang
    Tian, Chunlin
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [48] Numerical and experimental study on the relationship between pull-out force and indentation depth of aviation wire crimp terminal
    Pin Li
    Gongping Liu
    Ping Wang
    Guangwen Huang
    Zhuonan Yu
    Hang Xiu
    Chunlin Tian
    Scientific Reports, 12
  • [49] SIGNIFICANT DIFFERENCE BETWEEN 2 VALUES OF TORQUE FOR LAG SCREW AND SCREW WITH 2 THREADED HOLES IN CORTICAL BONE
    CLAES, L
    HUTZSCHENREUTER, P
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1974, 79 (04) : 347 - 352
  • [50] A Study on Self-tapping Design of Cortical Screw for Orthopaedic Application by Using Finite Element Analysis on Pull-out Strength and Bending Strength
    Thongnual, Phunyawat
    Khantachawana, Anak
    Tawonsawatruk, Tulyapruek
    2022 9TH INTERNATIONAL CONFERENCE ON BIOMEDICAL AND BIOINFORMATICS ENGINEERING, ICBBE 2022, 2022, : 209 - 214