Evaluation of the Relation Between Preload Values and Pull-Out Force of the Cortical Screw Used in Bone Fracture

被引:1
|
作者
Celik, Talip [1 ]
机构
[1] Kocaeli Univ, Fac Technol, Dept Biomed Engn, TR-41380 Kocaeli, Turkey
关键词
preload; pull-out strength; cortical screw; fracture fixation; OSTEOPOROSIS; FIXATION; ELEMENT; STRENGTH; BEHAVIOR;
D O I
10.1115/1.4051186
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study aims to examine the relation between pull-out strength and preload values of the cortical screw used in bone fracture fixation. The research question is that "Does the pull-out strength of the cortical screw used in the bone fracture fixation change with the preload values of the screw change?". To perform this purpose, the finite element method was selected due to its ease to evaluate and calculate the stresses on the whole model. Models of a cortical screw, partial plate, and bone were created using the SolidWorks program. The material properties of the bone were selected orthotropic material type. The bone fixed on the distal and proximal ends. The pull-out forces were applied at the bottom of the plate. The screw that has been loaded ranges from 100 N-700 N as preload. The pull-out forces were determined 200-400-600 N as in the literature. The results show that the pull-out strength of the screw was changed when the preloaded values higher than 400 N. However, it was seen that the pull-out strength does not substantially change when the preload values were lower than 400 N. When the preload values were applied >= 500 N, the maximum von Mises stresses on the screw exceeded the critical strength of the screw material. In conclusion, the critical preload value was determined as 500 N for the optimum pull-out strength.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Influence of a screw with a hinge on the pull-out force at the cranial end vertebra in ventral derotation spondylodesis (VDS)
    Klöckner, C
    Rohlmann, A
    Bergmann, G
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2003, 123 (08) : 410 - 413
  • [22] Influence of a screw with a hinge on the pull-out force at the cranial end vertebra in ventral derotation spondylodesis (VDS)
    C. Klöckner
    A. Rohlmann
    G. Bergmann
    Archives of Orthopaedic and Trauma Surgery, 2003, 123 : 410 - 413
  • [23] Investigation into the differences of pull-out resistance between normal and osteoporotic cancellous bone
    Liu, C.
    Guo, J. B.
    Yan, Y. H.
    2ND INTERNATIONAL CONFERENCE ON MATERIAL STRENGTH AND APPLIED MECHANICS, 2019, 629
  • [24] Comparison of the Pull-out Strength Between a Novel Micro-dynamic Pedicle Screw and a Traditional Pedicle Screw by Using Pull Out Test and Micro-CT
    Lei Qian
    Weidong Cheng
    Jun Ouyang
    医用生物力学, 2019, 34(S1) (S1) : 56 - 56
  • [25] Comparative Pull-Out Performances of Cephalomedullary Nail with Screw and Helical Blade According to Femur Bone Densities
    Park, Young-Chang
    Chae, Dong-Sik
    Kang, Kyung-Yil
    Ding, Yao
    Park, Sung-Jun
    Yoon, Jonghun
    APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 12
  • [26] Non-linear explicit micro-FE models accurately predict axial pull-out force of cortical screws in human tibial cortical bone
    Ovesy, Marzieh
    Silva-Henao, Juan Diego
    Fletcher, James W. A.
    Gueorguiev, Boyko
    Zysset, Philippe K.
    Varga, Peter
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 126
  • [27] Non-linear explicit micro-FE models accurately predict axial pull-out force of cortical screws in human tibial cortical bone
    Ovesy, Marzieh
    Silva-Henao, Juan Diego
    Fletcher, James W.A.
    Gueorguiev, Boyko
    Zysset, Philippe K.
    Varga, Peter
    Journal of the Mechanical Behavior of Biomedical Materials, 2022, 126
  • [28] Stronger bicortical sacral pedicle screw fixation through the S1 Endplate -: An in vitro cyclic loading and pull-out force evaluation
    Luk, KDK
    Chen, L
    Lu, WW
    SPINE, 2005, 30 (05) : 525 - 529
  • [29] Effect of Drilling Techniques on Microcracks and Pull-Out Strength of Cortical Screw Fixed in Human Tibia: An In-Vitro Study
    Ravinder Pal Singh
    Vishal Gupta
    Pulak Mohan Pandey
    Asit Ranjan Mridha
    Annals of Biomedical Engineering, 2021, 49 : 382 - 393
  • [30] Effect of Drilling Techniques on Microcracks and Pull-Out Strength of Cortical Screw Fixed in Human Tibia: An In-Vitro Study
    Singh, Ravinder Pal
    Gupta, Vishal
    Pandey, Pulak Mohan
    Mridha, Asit Ranjan
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (01) : 382 - 393