Evaluation of the Relation Between Preload Values and Pull-Out Force of the Cortical Screw Used in Bone Fracture

被引:1
|
作者
Celik, Talip [1 ]
机构
[1] Kocaeli Univ, Fac Technol, Dept Biomed Engn, TR-41380 Kocaeli, Turkey
关键词
preload; pull-out strength; cortical screw; fracture fixation; OSTEOPOROSIS; FIXATION; ELEMENT; STRENGTH; BEHAVIOR;
D O I
10.1115/1.4051186
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study aims to examine the relation between pull-out strength and preload values of the cortical screw used in bone fracture fixation. The research question is that "Does the pull-out strength of the cortical screw used in the bone fracture fixation change with the preload values of the screw change?". To perform this purpose, the finite element method was selected due to its ease to evaluate and calculate the stresses on the whole model. Models of a cortical screw, partial plate, and bone were created using the SolidWorks program. The material properties of the bone were selected orthotropic material type. The bone fixed on the distal and proximal ends. The pull-out forces were applied at the bottom of the plate. The screw that has been loaded ranges from 100 N-700 N as preload. The pull-out forces were determined 200-400-600 N as in the literature. The results show that the pull-out strength of the screw was changed when the preloaded values higher than 400 N. However, it was seen that the pull-out strength does not substantially change when the preload values were lower than 400 N. When the preload values were applied >= 500 N, the maximum von Mises stresses on the screw exceeded the critical strength of the screw material. In conclusion, the critical preload value was determined as 500 N for the optimum pull-out strength.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Bone density optimized pedicle screw instrumentation improves screw pull-out force in lumbar vertebrae
    Caprara, Sebastiano
    Fasser, Marie-Rosa
    Spirig, Jose Miguel
    Widmer, Jonas
    Snedeker, Jess G.
    Farshad, Mazda
    Senteler, Marco
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (04) : 464 - 474
  • [2] Biomechanical evaluation of the screw preload values used in the plate placement for bone fractures
    Celik, Talip
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2021, 235 (02) : 141 - 147
  • [3] Relationship between clamp force and pull-out strength in lag screw timber joints
    Matsubara, Doppo
    Wakashima, Yoshiaki
    Fujisawa, Yasushi
    Shimizu, Hidemaru
    Kitamori, Akihisa
    Ishikawa, Koichiro
    JOURNAL OF WOOD SCIENCE, 2017, 63 (06) : 625 - 634
  • [4] Relationship between clamp force and pull-out strength in lag screw timber joints
    Doppo Matsubara
    Yoshiaki Wakashima
    Yasushi Fujisawa
    Hidemaru Shimizu
    Akihisa Kitamori
    Koichiro Ishikawa
    Journal of Wood Science, 2017, 63 : 625 - 634
  • [5] Screw pull-out force is dependent on screw orientation in an anterior cervical plate construct
    DiPaola, Christian P.
    Jacobson, Justin A.
    Awad, Hani
    Conrad, Bryan P.
    Rechtine, Glenn R., II
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (05): : 369 - 373
  • [6] FRACTURE FIXATION BY CERCLAGE WIRING UTILIZING CORTICAL BONE TACKS AND A PULL-OUT TENSION DEVICE
    JOHNSON, RA
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 1977, 13 (01) : 105 - 113
  • [7] A Computational Approximation to Model Variation in Cancellous Bone Screw Pull-Out
    Piper, A.
    Brown, C. J.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (02):
  • [8] Effects of bone materials on the screw pull-out strength in human spine
    Zhang, Qing Hang
    Tan, Soon Huat
    Chou, Siaw Meng
    MEDICAL ENGINEERING & PHYSICS, 2006, 28 (08) : 795 - 801
  • [9] Effect of surface topography on pull-out strength of cortical screw after ultrasonic bone drilling: an in vitro study
    Raj Agarwal
    Vivek Jain
    Vishal Gupta
    Sanjai Saxena
    Vagish Dwibedi
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42
  • [10] Effect of surface topography on pull-out strength of cortical screw after ultrasonic bone drilling: an in vitro study
    Agarwal, Raj
    Jain, Vivek
    Gupta, Vishal
    Saxena, Sanjai
    Dwibedi, Vagish
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2020, 42 (07)