Registration Accuracy of Patient-Specific, Three-Dimensional-Printed Prostate Molds for Correlating Pathology With Magnetic Resonance Imaging

被引:9
|
作者
Priester, Alan [1 ,2 ]
Wu, Holden [3 ]
Khoshnoodi, Pooria [3 ]
Schneider, Douglas [4 ]
Zhang, Zhaohuan [3 ]
Asvadi, Nazanin H. [3 ]
Sisk, Anthony [5 ]
Raman, Steven [3 ]
Reiter, Robert [2 ]
Grundfest, Warren [1 ]
Marks, Leonard S. [2 ]
Natarajan, Shyam [2 ]
机构
[1] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Urol, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Dept Ecol & Evolutionary Biol, Los Angeles, CA USA
[5] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pathol, Los Angeles, CA 90095 USA
关键词
Image registration; magnetic resonance imaging; pathology; phantoms; three-dimensional printing; MULTIPARAMETRIC MRI; HISTOLOGY; CANCER; SPECIMENS; METHODOLOGY; VALIDATION; ULTRASOUND; IMAGES; VOLUME;
D O I
10.1109/TBME.2018.2828304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: This investigation was performed to evaluate the registration accuracy between magnetic resonance imaging (MRI) and pathology using three-dimensional (3-D) printed molds. Methods: Tissue-mimicking prostate phantoms were manufactured with embedded fiducials. The fiducials were used to measure and compare target registration error (TRE) between phantoms that were sliced by hand versus phantoms that were sliced within 3-D-printed molds. Subsequently, ten radical prostatectomy specimens were placed inside molds, scanned with MRI, and then sliced. The ex vivo scan was used to assess the true location of whole mount (WM) slides relative to in vivo MRI. The TRE between WM and in vivo MRI was measured using anatomic landmarks. Results: Manually sliced phantoms had a 4.1-mm mean TRE, whereas mold-sliced phantoms had a 1.9-mmmean TRE. Similarly, mold-assisted slicing reduced mean angular misalignment around the left-right (LR) anatomic axis from 10.7 degrees to 4.5 degrees. However, ex vivo MRI revealed that excised prostates were misaligned within molds, including a mean 14 degrees rotation about the LR axis. The mean in-plane TRE was 3.3 mm using molds alone and 2.2 mm after registration was corrected with ex vivo MRI. Conclusion: Patient-specific molds improved accuracy relative to manual slicing techniques in a phantom model. However, the registration accuracy of surgically resected specimens was limited by their imperfect fit within molds. This limitation can be overcome with the addition of ex vivo imaging. Significance: The accuracy of 3-D-printed molds was characterized, quantifying their utility for facilitating MRI-pathology registration.
引用
收藏
页码:14 / 22
页数:9
相关论文
共 50 条
  • [31] Three-dimensional-printed patient-specific instrumentation is an accurate tool to reproduce femoral bone tunnels in multiple-ligament knee injuries
    Fernandez-Poch, Nuria
    Fillat-Goma, Ferran
    Martinez-Carreres, Laia
    Coderch-Navarro, Sergi
    Yela-Verdu, Christian
    Carbo-Cedan, Sonia
    Pelfort, Xavier
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (05) : 1213 - 1219
  • [32] Three-Dimensional-Printed Patient-Specific Osteotomy Guides, Repositioning Guides and Titanium Plates for Acute Correction of Antebrachial Limb Deformities in Dogs
    Carwardine, Darren R.
    Gosling, Mark J.
    Burton, Neil J.
    O'Malley, Ffion L.
    Parsons, Kevin J.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2021, 34 (01) : 43 - 52
  • [33] Three-dimensional-printed patient-specific instrumentation is an accurate tool to reproduce femoral bone tunnels in multiple-ligament knee injuries
    Núria Fernández-Poch
    Ferran Fillat-Gomà
    Laia Martínez-Carreres
    Sergi Coderch-Navarro
    Christian Yela-Verdú
    Sonia Carbó-Cedán
    Xavier Pelfort
    International Orthopaedics, 2023, 47 : 1213 - 1219
  • [34] Three-dimensional printed patient-specific implants - The future work horse
    Gunishetty, Vikas
    Hegde, Padmaraj J.
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2020, 152 (07) : 16 - 17
  • [35] Three-Dimensional Printed Patient-Specific Vestibular Augmentation: A Case Report
    Johansson, Linh
    Latorre, Jose Luis
    Liversain, Margaux
    Thorel, Emilie
    Raymond, Yago
    Ginebra, Maria-Pau
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (08)
  • [36] A three-dimensional printed patient-specific scaphoid replacement: a cadaveric study
    Honigmann, Philipp
    Schumacher, Ralf
    Marek, Romy
    Buttner, Franz
    Thieringer, Florian
    Haefeli, Mathias
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (04) : 407 - 412
  • [37] Students' Perception of Remote Extended Reality Simulation Systems Using Patient-specific Three-Dimensional-printed Models in Endodontic Education: A Pilot Study
    Alroomy, Riyadh
    Almimoni, Munirah
    Alotaibi, Abdulaaly
    Almutairi, Ahad
    Alyahya, Ebtesam
    Unozawa, Motoharu
    Kakumoto, Takahito
    Okazaki, Katsushi
    EUROPEAN ENDODONTIC JOURNAL, 2024, 9 (03): : 273 - 278
  • [38] Comparison of digitally assessed quality of posterior crown preparations performed with and without previous practice on patient-specific three-dimensional-printed teeth models
    Tricio, Jorge A.
    Braithwaite, Catalina
    Herrera, Constanza M.
    Vicuna, Daniela P.
    Cacciuttolo, Franco R.
    Jorquera, Gilbert A.
    Gutierrez, Mario F.
    Cordova, Christian G.
    Villalon, Pablo A.
    Moncada, Gustavo A.
    Casanova, Renzo A.
    Gonzalez, Maria I.
    Ilic, Macarena A.
    Orsini, Cesar A.
    JOURNAL OF DENTAL EDUCATION, 2024, 88 (09) : 1247 - 1256
  • [39] Correlating magnetic resonance and molecular imaging using three dimensional untreated virtual control
    Jacobs, Joshua
    Hawkins-Darrud, Andrea
    Harrison, Robert
    Johnston, Sandra
    Kinahan, Paul
    Swanson, Kristin
    CANCER RESEARCH, 2017, 77
  • [40] Patient-specific mapping of fundus photographs to three-dimensional ocular imaging
    Haasjes, Corne
    Vu, T. H. Khanh
    Beenakker, Jan-Willem M.
    MEDICAL PHYSICS, 2025, 52 (04) : 2330 - 2339