Registration Accuracy of Patient-Specific, Three-Dimensional-Printed Prostate Molds for Correlating Pathology With Magnetic Resonance Imaging

被引:9
|
作者
Priester, Alan [1 ,2 ]
Wu, Holden [3 ]
Khoshnoodi, Pooria [3 ]
Schneider, Douglas [4 ]
Zhang, Zhaohuan [3 ]
Asvadi, Nazanin H. [3 ]
Sisk, Anthony [5 ]
Raman, Steven [3 ]
Reiter, Robert [2 ]
Grundfest, Warren [1 ]
Marks, Leonard S. [2 ]
Natarajan, Shyam [2 ]
机构
[1] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Urol, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, Dept Ecol & Evolutionary Biol, Los Angeles, CA USA
[5] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pathol, Los Angeles, CA 90095 USA
关键词
Image registration; magnetic resonance imaging; pathology; phantoms; three-dimensional printing; MULTIPARAMETRIC MRI; HISTOLOGY; CANCER; SPECIMENS; METHODOLOGY; VALIDATION; ULTRASOUND; IMAGES; VOLUME;
D O I
10.1109/TBME.2018.2828304
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: This investigation was performed to evaluate the registration accuracy between magnetic resonance imaging (MRI) and pathology using three-dimensional (3-D) printed molds. Methods: Tissue-mimicking prostate phantoms were manufactured with embedded fiducials. The fiducials were used to measure and compare target registration error (TRE) between phantoms that were sliced by hand versus phantoms that were sliced within 3-D-printed molds. Subsequently, ten radical prostatectomy specimens were placed inside molds, scanned with MRI, and then sliced. The ex vivo scan was used to assess the true location of whole mount (WM) slides relative to in vivo MRI. The TRE between WM and in vivo MRI was measured using anatomic landmarks. Results: Manually sliced phantoms had a 4.1-mm mean TRE, whereas mold-sliced phantoms had a 1.9-mmmean TRE. Similarly, mold-assisted slicing reduced mean angular misalignment around the left-right (LR) anatomic axis from 10.7 degrees to 4.5 degrees. However, ex vivo MRI revealed that excised prostates were misaligned within molds, including a mean 14 degrees rotation about the LR axis. The mean in-plane TRE was 3.3 mm using molds alone and 2.2 mm after registration was corrected with ex vivo MRI. Conclusion: Patient-specific molds improved accuracy relative to manual slicing techniques in a phantom model. However, the registration accuracy of surgically resected specimens was limited by their imperfect fit within molds. This limitation can be overcome with the addition of ex vivo imaging. Significance: The accuracy of 3-D-printed molds was characterized, quantifying their utility for facilitating MRI-pathology registration.
引用
收藏
页码:14 / 22
页数:9
相关论文
共 50 条
  • [21] Re: Magnetic Resonance Imaging Underestimation of Prostate Cancer Geometry: Use of Patient Specific Molds to Correlate Images with Whole Mount Pathology
    Orczyk, Clement
    Emberton, Mark
    JOURNAL OF UROLOGY, 2017, 198 (06): : 1436 - 1436
  • [22] Accuracy and safety of in-house surgeon-designed three-dimensional-printed patient-specific implants for wafer-less Le Fort I osteotomy
    Leung, Yiu Yan
    Leung, Jasper Ka Chai
    Li, Alvin Tsz Choi
    Teo, Nathan En Zuo
    Leung, Karen Pui Yan
    Au, Shun Wai
    Li, Dion Tik Shun
    Su, Yu-Xiong
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (02) : 705 - 713
  • [23] Accuracy and safety of in-house surgeon-designed three-dimensional-printed patient-specific implants for wafer-less Le Fort I osteotomy
    Yiu Yan LEUNG
    Jasper Ka Chai LEUNG
    Alvin Tsz Choi LI
    Nathan En Zuo TEO
    Karen Pui Yan LEUNG
    Shun Wai AU
    Dion Tik Shun LI
    Yu-Xiong SU
    Clinical Oral Investigations, 2023, 27 : 705 - 713
  • [24] Limb-sparing in dogs using patient-specific, three-dimensional-printed endoprosthesis for distal radial osteosarcoma: A pilot study
    Seguin, Bernard
    Pinard, Chris
    Lussier, Bertrand
    Williams, Deanna
    Griffin, Lynn
    Podell, Brendan
    Mejia, Sebastian
    Timercan, Anatolie
    Petit, Yvan
    Brailovski, Vladimir
    VETERINARY AND COMPARATIVE ONCOLOGY, 2020, 18 (01) : 92 - 104
  • [25] Three-dimensional-printed patient-specific Kirschner-wire guide for percutaneous fixation of undisplaced scaphoid fractures: a cadaveric study
    Salabi, Vincent
    Rigoulot, Guillaume
    Sautet, Alain
    Cambon-Binder, Adeline
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2019, 44 (07) : 692 - 696
  • [26] Re: Magnetic Resonance Imaging Underestimation of Prostate Cancer Geometry: Use of Patient Specific Molds to Correlate Images with Whole Mount Pathology Reply
    不详
    JOURNAL OF UROLOGY, 2017, 198 (03): : 709 - 709
  • [27] Re: Magnetic Resonance Imaging Underestimation of Prostate Cancer Geometry: Use of Patient Specific Molds to Correlate Images with Whole Mount Pathology Reply
    不详
    JOURNAL OF UROLOGY, 2017, 198 (06): : 1437 - 1437
  • [28] Magnetic Resonance Imaging of the Ear for Patient-Specific Reconstructive Surgery
    Nimeskern, Luc
    Feldmann, Eva-Maria
    Kuo, Willy
    Schwarz, Silke
    Goldberg-Bockhorn, Eva
    Duerr, Susanne
    Mueller, Ralph
    Rotter, Nicole
    Stok, Kathryn S.
    PLOS ONE, 2014, 9 (08):
  • [29] Accuracy of three-dimensional printed patient-specific drill guides for treatment of canine humeral intracondylar fissure
    Easter, Tim G.
    Bilmont, Alexis
    Pink, Jonathan
    Oxley, Bill
    VETERINARY SURGERY, 2020, 49 (02) : 363 - 372
  • [30] Vertebral body replacement using patient-specific three-dimensional-printed polymer implants in cervical spondylotic myelopathy: an encouraging preliminary report
    Amelot, Aymeric
    Colman, Matthew
    Loret, Jean-Edouard
    SPINE JOURNAL, 2018, 18 (05): : 892 - 899