The Athena X-IFU Instrument Simulator xifusim

被引:6
|
作者
Kirsch, C. [1 ]
Lorenz, M. [1 ]
Peille, P. [2 ]
Dauser, T. [1 ]
Ceballos, M. T. [3 ]
Cobo, B. [3 ]
Merino-Alonso, P. E. [4 ,5 ]
Cucchetti, E. [2 ]
Smith, S. J. [6 ]
Gottardi, L. [7 ]
den Hartog, R. H. [1 ]
Miniussi, A. [6 ]
Durkin, M. [8 ]
Prele, D. [9 ]
Wilms, J. [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg, Dr Karl Remeis Observ & ECAP, Sternwartstr 7, D-96049 Bamberg, Germany
[2] CNES, 18 Ave Edouard Belin, F-31401 Toulouse 9, France
[3] Inst Fis Cantabria CSIC UC, Edificio Juan Jorda,Ave Castros S-N, Santander 39005, Cantabria, Spain
[4] Univ Politecn Madrid, Calle Ramiro de Maeztu 7, Madrid 28040, Spain
[5] Univ Alicante, Carr San Vicente del Raspeig S-N, Alicante 03690, Spain
[6] NASA, Goddard Space Flight Ctr, 8800 Greenbelt Rd, Greenbelt, MD USA
[7] SRON Netherlands Inst Space Reseach, Niels Bohrweg 4, NL-2333 CA Leiden, Netherlands
[8] NIST, 325 Broadway, Boulder, CO USA
[9] Univ Paris, CNRS, Astroparticule & Cosmol, F-75006 Paris, France
关键词
Athena; X-IFU; TES; Simulations;
D O I
10.1007/s10909-022-02700-4
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present the instrument simulator xifusim developed for the X-ray Integral Field Unit X-IFU aboard the planned Athena mission. xifusim aims to be an accurate representation of the entire instrument, starting from a full simulation of the Transition-Edge Sensor (TES) array receiving impact photons unconstrained by the small signal limit. Its output current is then propagated through the entire readout chain, including multiplexing, amplification and the digital readout. The final output consists of triggered records, which can be post-processed to reconstruct the photon energies. The readout chain itself is separated into individual, modular blocks with several possible models for each, allowing the simulation of different readout schemes or models of varying physical accuracy at the expense of run time. New models are implemented as necessary to enable studies of the overall readout chain. Such studies are also facilitated by fine-grained control of the simulation output, including the internal state of intermediate simulation blocks. In addition to its modularity, xifusim also allows the manipulation of certain internal parameters during a run, enabling the simulation of readout chain characterization measurements, environmental drifts or various kinds of crosstalk.
引用
收藏
页码:988 / 997
页数:10
相关论文
共 50 条
  • [21] The end-to-end simulator of the ATHENA X-IFU Cryogenic AntiCoincidence detector (CryoAC)
    D'Andrea, M.
    Macculi, C.
    Lotti, S.
    Piro, L.
    Argan, A.
    Minervini, G.
    Torrioli, G.
    Chiarello, F.
    Barusso, L. Ferrari
    Gatti, F.
    Rigano, M.
    SPACE TELESCOPES AND INSTRUMENTATION 2024: ULTRAVIOLET TO GAMMA RAY, PT 1, 2024, 13093
  • [22] The particle background of the X-IFU instrument
    Simone Lotti
    Teresa Mineo
    Christian Jacquey
    Silvano Molendi
    Matteo D’Andrea
    Claudio Macculi
    Luigi Piro
    Experimental Astronomy, 2017, 44 : 371 - 385
  • [23] Conceptual design of the X-IFU Instrument Control Unit on board the ESA Athena mission
    Corcione, L.
    Ligori, S.
    Capobianco, V.
    Bonino, D.
    Valenziano, L.
    Guizzo, G. P.
    SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
  • [24] Coolers development for the Athena X-IFU cryogenic chain
    Duband, L.
    Charles, I.
    Duval, J. M.
    SPACE TELESCOPES AND INSTRUMENTATION 2014: ULTRAVIOLET TO GAMMA RAY, 2014, 9144
  • [25] Aperture cylinder on Athena X-IFU: development status
    Thibert, T.
    Jacques, L.
    Terrasa, G.
    Lallemand, E.
    Rauw, G.
    Kintziger, C.
    SPACE TELESCOPES AND INSTRUMENTATION 2022: ULTRAVIOLET TO GAMMA RAY, 2022, 12181
  • [26] SIRENA: Software for Athena X-IFU Event Reconstruction
    Ceballos, M. T.
    Cobo, B.
    Peille, P.
    Wilms, J.
    Brand, T.
    Dauser, T.
    Bandler, S.
    Smith, S.
    ASTRONOMICAL DATA ANALYSIS SOFTWARE AND SYSTEMS XXVI, 2019, 521 : 663 - 666
  • [27] The mechanical and EM simulations of the CryoAC for the ATHENA X-IFU
    Corsini, D.
    Biasotti, M.
    Gatti, F.
    De Gerone, M.
    Rossi, C.
    Piro, L.
    Macculi, C.
    SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
  • [28] Characterizing Thermal Background Events for Athena X-IFU
    Hull, S. V.
    Adams, J. S.
    Bandler, S. R.
    Beaumont, S.
    Chervenak, J. A.
    Cumbee, R.
    Finkbeiner, F. M.
    Ha, J. Y.
    Kelley, R. L.
    Kilbourne, C. A.
    Porter, F. S.
    Sakai, K.
    Smith, S. J.
    Wakeham, N. A.
    Wassell, E. J.
    Yoon, S. H.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2023, 33 (05)
  • [29] The particle background of the X-IFU instrument
    Lotti, Simone
    Mineo, Teresa
    Jacquey, Christian
    Molendi, Silvano
    D'Andrea, Matteo
    Macculi, Claudio
    Piro, Luigi
    EXPERIMENTAL ASTRONOMY, 2017, 44 (03) : 371 - 385
  • [30] The defocused observations of bright sources with Athena/X-IFU
    Kammoun, E. S.
    Barret, D.
    Peille, P.
    Willingale, R.
    Dauser, T.
    Wilms, J.
    Guainazzi, M.
    Miller, J. M.
    ASTRONOMY & ASTROPHYSICS, 2022, 664