Influence of various gypsum materials on precision of fit of CAD/CAM-fabricated zirconia copings

被引:8
|
作者
Kim, Jae-Hong [1 ]
Kim, Ki-Baek [1 ]
Kim, Woong-Chul [1 ]
Rhee, Hyun-Sill [2 ]
Lee, Il-Hyun [3 ]
Kim, Ji-Hwan [1 ]
机构
[1] Korea Univ, Coll Hlth Sci, Dept Dent Lab Sci & Engn, 161 Jeongneung Ro, Seoul 136712, South Korea
[2] Korea Univ, Coll Hlth Sci, Dept Healthcare Management, Seoul 136712, South Korea
[3] StatEdu, Inst Stat & Educ Consulting, Seoul 136712, South Korea
关键词
Dental CAD/CAM; Fit; Type IV gypsum; Zirconia coping; INTERNAL FIT;
D O I
10.4012/dmj.2014-141
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The clinical applicability of CAD/CAM-fabricated zirconia copings is tested using working models made from four different high-strength Type IV gypsum materials. Each of the four materials was used to fabricate 15 zirconia copings. Precision of fit was measured with a digital electron microscope using the silicone replica technique. The mean and standard deviation of each reference point were analyzed using the one-way analysis of the variance (ANOVA) and Tukey's honest significant difference (HSD) tests (alpha=0.05). The overall marginal and internal fits of the zirconia copings were as follows: GS (GS: Grey Stone) group: 91.43 mu m, LS (LS: Light green Stone) Group: 87.89 mu m, RS (RS: Red Stone) Group: 88.75 mu m, BS (BS: Beige Stone) Group: 82.78 mu m. There were no significant differences between the mean adaptations of the gypsum varieties (p>0.05). This confirmed that the type of gypsum material used does not determine the precision of fit of a prosthesis.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [41] SEM evaluation of the precision of fit of CAD/CAM zirconia and metal-ceramic posterior crowns
    Ortega, Rocio
    Gonzalo, Esther
    Gomez-Polo, Miguel
    Lopez-Suarez, Carlos
    Suarez, Maria J.
    DENTAL MATERIALS JOURNAL, 2017, 36 (04) : 387 - 393
  • [42] Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances
    Roser, Christoph
    Hodecker, Lutz D.
    Koebel, Chris
    Lux, Christopher J.
    Ruckes, Dorothee
    Rues, Stefan
    Zenthoefer, Andreas
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [43] Evaluation of the fit of zirconia copings fabricated by direct and indirect digital scanning procedures
    Lee, Bora
    Oh, Kyung Chul
    Haam, Daewon
    Lee, Joon-Hee
    Moon, Hong-Seok
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (02): : 225 - 231
  • [44] Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances
    Christoph Roser
    Lutz D. Hodecker
    Chris Koebel
    Christopher J. Lux
    Dorothee Ruckes
    Stefan Rues
    Andreas Zenthöfer
    Scientific Reports, 11
  • [45] Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems
    Bae, Eun-Bin
    Cho, Won-Tak
    Park, Do-Hyun
    Hwang, Su-Hyun
    Lee, So-Hyoun
    Yun, Mi-Jung
    Jeong, Chang-Mo
    Huh, Jung-Bo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (03): : 155 - 170
  • [46] Influence of CAD/CAM scanning method and tooth-preparation design on the vertical misfit of zirconia crown copings
    Castillo Oyaguee, Raquel
    Isabel Sanchez-Jorge, Maria
    Sanchez Turrion, Andres
    AMERICAN JOURNAL OF DENTISTRY, 2010, 23 (06): : 341 - 346
  • [47] Comparison of Marginal Fit of Zirconia Copings Produced by Different Systems and Materials
    Gultekin, Pinar
    Sen, Deniz
    Aydin, Murat
    JOURNAL OF ISTANBUL UNIVERSITY FACULTY OF DENTISTRY, 2013, 47 (01) : 28 - 37
  • [48] Effects of scanning technique on in vitro performance of CAD/CAM-fabricated fiber posts
    Tsintsadze, Nino
    Juloski, Jelena
    Carrabba, Michele
    Goracci, Cecilia
    Vichi, Alessandro
    Grandini, Simone
    Ferrari, Marco
    JOURNAL OF ORAL SCIENCE, 2018, 60 (02) : 262 - 268
  • [49] Reconstruction of the cranial vault using CAD/CAM-fabricated glass bioceramic implants
    Balossier, A.
    Durand, A.
    Achim, V. -V.
    Noudel, R.
    Hurel, S.
    Emery, E.
    NEUROCHIRURGIE, 2011, 57 (01) : 21 - 27
  • [50] Influence of cementation on in vitro performance, marginal adaptation and fracture resistance of CAD/CAM-fabricated ZLS molar crowns
    Preis, Verena
    Behr, Michael
    Hahnel, Sebastian
    Rosentritt, Martin
    DENTAL MATERIALS, 2015, 31 (11) : 1363 - 1369