Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances

被引:0
|
作者
Christoph Roser
Lutz D. Hodecker
Chris Koebel
Christopher J. Lux
Dorothee Ruckes
Stefan Rues
Andreas Zenthöfer
机构
[1] Heidelberg University Hospital,Department of Orthodontics and Dentofacial Orthopaedics
[2] University of Heidelberg,Department of Prosthodontics, Heidelberg University Hospital
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Manufacturing of Fränkel's functional regulator 3 (FR3) is complicated and requires extensive knowledge from the dental technician. To determine whether FR3s produced by CAD/CAM techniques (CAD-FR3) meet similar mechanical properties like conventional FR3s (Con-FR3), for each of 10 patient cases, three CAD-FR3 designs (palatal connector cross-section 3 × 3 mm, 4 × 1 mm or 5 × 2 mm) and one Con-FR3 were subjected to cyclic loading and subsequent fracture testing in a universal testing device. Transversal load capacity (Fmax(FR3)) and stiffness were compared among the different CAD-FR3 designs and Con-FR3s using Friedman and Wilcoxon tests with a significance level of α = 0.05. All CAD-FR3 designs had significantly higher mean Fmax(FR3) (p ≤ 0.007) and stiffness (p ≤ 0.005) than the Con-FR3s. The CAD-FR33×3 had the highest mean Fmax(FR3) (98.2 ± 26.2 N) and stiffness (37.1 ± 15.5 N/mm), closely followed by the CAD-FR35×2 (Fmax(FR3): 90.3 ± 24.7 N; stiffness: 30.0 ± 12.3 N/mm). Among the CAD appliances, CAD-FR34×1 had the lowest values (p ≤ 0.007 for all pairwise tests) with Fmax(FR3) of 45.8 ± 17.9 N and stiffness of 12.5 ± 7.3 N/mm. CAD-FR3s have superior mechanical properties in comparison to Con-FR3s if certain design parameters are followed. Further clinical investigations have to examine if they can serve as an alternative in practice.
引用
收藏
相关论文
共 50 条
  • [1] Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances
    Roser, Christoph
    Hodecker, Lutz D.
    Koebel, Chris
    Lux, Christopher J.
    Ruckes, Dorothee
    Rues, Stefan
    Zenthoefer, Andreas
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Optical properties of manually and CAD/CAM-fabricated polymers
    Gueth, Jan-Frederik
    Zuch, Timo
    Zwinge, Sebastian
    Engels, Joerg
    Stimmelmayr, Michael
    Edelhoff, Daniel
    DENTAL MATERIALS JOURNAL, 2013, 32 (06) : 865 - 871
  • [3] CAD/CAM-fabricated removable partial dentures: a case report
    Carneiro Pereira, Ana Larisse
    Martins de Aquino, Luana Maria
    Carvalho Porto de Freitas, Rodrigo Falcao
    Soares Paiva Torres, Ana Clara
    Porto Carreiro, Adriana da Fonte
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2019, 22 (04) : 371 - 379
  • [4] Differences in Radiopacity, Surface Properties, and Plaque Accumulation for CAD/CAM-Fabricated vs Conventionally Processed Polymer-based Temporary Materials
    Zadeh, P. Nassary
    Luemkemann, N.
    Eichberger, M.
    Stawarczyk, B.
    Kollmuss, M.
    OPERATIVE DENTISTRY, 2020, 45 (04) : 407 - 415
  • [5] Digital Relief of the Mental Foramen for a CAD/CAM-Fabricated Mandibular Denture
    Ohkubo, Chikahiro
    Park, Eun-Jin
    Kim, Tae Hyung
    Kurtz, Kenneth S.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (02): : 189 - 192
  • [6] CAD/CAM-fabricated implant-supported restorations: a systematic review
    Patzelt, Sebastian Berthold Maximilian
    Spies, Benedikt C.
    Kohal, Ralf J.
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 : 77 - 85
  • [7] Effect of Deep Margin Elevation on CAD/CAM-Fabricated Ceramic Inlays
    Vertolli, T. J.
    Martinsen, B. D.
    Hanson, C. M.
    Howard, R. S.
    Kooistra, S.
    Ye, L.
    OPERATIVE DENTISTRY, 2020, 45 (06) : 608 - 617
  • [8] Tribology, Characterization, and Surface Roughness Study of a CAD/CAM-Fabricated Zirconia
    Patil A.
    Jebaseelan D.D.
    J. Bio Tribo Corros., 2020, 2 (2):
  • [9] CAD/CAM-fabricated high-performance polymers in implant dentistry
    Beuer, Florian
    Schweiger, Josef
    Stimmelmayr, Michael
    Edelhoff, Daniel
    IMPLANTOLOGIE, 2010, 18 (04): : 397 - 404
  • [10] CAD/CAM-Fabricated Nonmetal Clasp Denture: In Vitro Pilot Study
    Takahashi, Yutaka
    Hamanaka, Ippei
    Isshi, Kota
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (03) : 277 - 279