Source and detector calibration in the UV and VUV at BESSY II

被引:39
|
作者
Richter, M [1 ]
Hollandt, J [1 ]
Kroth, U [1 ]
Paustian, W [1 ]
Rabus, H [1 ]
Thornagel, R [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
D O I
10.1088/0026-1394/40/1/324
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
After the shutdown of the BESSY I electron storage ring, PTB's two normal-incidence monochromator beamlines for the calibration of radiation sources and detectors in the wavelength range from 40 nm to 400 nm were transferred to PTB's new radiometry laboratory at BESSY II. In this paper, the beamlines and their properties are briefly described. First results for the calibration of secondary source standards and detector standards at BESSY II are shown and demonstrate the successful re-establishment of the measurement capabilities. In the ultraviolet, calibration of deuterium lamps was reproduced within 1% and of silicon trap photodetectors within 0.2%.
引用
收藏
页码:S107 / S110
页数:4
相关论文
共 50 条
  • [21] UV-VUV radiation calibration facility based on synchrotron radiation
    Department of Optical Engineering, School of Information Science and Technology, Beijing Institute of Technology, Beijing 100081, China
    不详
    不详
    Beijing Ligong Daxue Xuebao, 2007, 9 (807-810):
  • [22] Status of the high brilliance synchrotron radiation source BESSY-II
    Jaeschke, E
    Khan, S
    Kramer, D
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 1411 - 1413
  • [23] 1ST EXPERIMENTAL EXPERIENCE WITH A VUV POLARIMETER AT BESSY
    GAUPP, A
    MAST, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2213 - 2215
  • [24] Characterization of laser-electron interaction at the BESSY II femtoslicing source
    Holldack, K
    Kachel, T
    Khan, S
    Mitzner, R
    Quast, T
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2005, 8 (04): : 31 - 37
  • [25] CALIBRATION OF VUV SPECTROMETER-DETECTOR SYSTEM USING SYNCHROTRON RADIATION.
    McPherson, Armon
    Rouze, N.
    Westerveld, W.B.
    Risley, John S.
    Applied Optics, 1986, 25 (02): : 298 - 310
  • [26] LATTICE COMPARISON FOR THE SYNCHROTRON LIGHT-SOURCE BESSY-II
    WUSTEFELD, G
    ISOYAMA, G
    LEHR, H
    SIMON, B
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 1265 - 1267
  • [27] Development of the calibration device using UAV mounted UV-LED light source for the fluorescence detector
    Tomida, Takayuki
    Inadomi, Taichi
    Seki, Terutsugu
    Tameda, Yuichiro
    Oku, Yuya
    Sano, Kengo
    ULTRA HIGH ENERGY COSMIC RAYS 2018 (UHECR 2018), 2019, 210
  • [28] Status of the High Brilliance Synchrotron Light Source BESSY-II
    Jaeschke, E
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 713 - 715
  • [29] Alignment and Calibration of the Belle II Detector
    Bilka, Tadeas
    Chilikin, Kirill
    Dossett, David
    Guan, Yinghui
    Kandra, Jakub
    Kleinwort, Claus
    Sevior, Martin
    23RD INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2018), 2019, 214
  • [30] The study on the spectral irradiance responsiveness calibration for UV-VUV solar spectrometer
    Li, Hanshuang
    Li, Bo
    Wang, Shurong
    Li, Zhigang
    Li, Futian
    OPTIK, 2020, 208