Source and detector calibration in the UV and VUV at BESSY II

被引:39
|
作者
Richter, M [1 ]
Hollandt, J [1 ]
Kroth, U [1 ]
Paustian, W [1 ]
Rabus, H [1 ]
Thornagel, R [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
D O I
10.1088/0026-1394/40/1/324
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
After the shutdown of the BESSY I electron storage ring, PTB's two normal-incidence monochromator beamlines for the calibration of radiation sources and detectors in the wavelength range from 40 nm to 400 nm were transferred to PTB's new radiometry laboratory at BESSY II. In this paper, the beamlines and their properties are briefly described. First results for the calibration of secondary source standards and detector standards at BESSY II are shown and demonstrate the successful re-establishment of the measurement capabilities. In the ultraviolet, calibration of deuterium lamps was reproduced within 1% and of silicon trap photodetectors within 0.2%.
引用
收藏
页码:S107 / S110
页数:4
相关论文
共 50 条
  • [11] Commissioning results from the BESSY II femtoslicing source
    Khan, S
    Holldack, K
    Kachel, T
    Quast, T
    Mitzner, R
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 1515 - 1517
  • [12] CALIBRATION OF A VUV SPECTROMETER DETECTOR SYSTEM USING SYNCHROTRON RADIATION
    MCPHERSON, A
    ROUZE, N
    WESTERVELD, WB
    RISLEY, JS
    APPLIED OPTICS, 1986, 25 (02) : 298 - 310
  • [13] Improvement of the beamline for calibration of the transfer standard in the UV and VUV regions
    Zama, T
    Saito, I
    METROLOGIA, 2003, 40 (01) : S115 - S119
  • [14] Adaption of the BESSY I-3m normal incidence monochromators to the BESSY II source
    Reichardt, G
    Noll, T
    Packe, I
    Rotter, P
    Schmidt, JS
    Gudat, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 458 - 461
  • [15] Quantum Efficiency Calibration of UV-VUV Photomultiplier Tube
    Li Hanshuang
    Li Bo
    Wang Shurong
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2018, 45 (08):
  • [17] Calibration of transfer standard light source in the UV and VUV regions using SR from the storage ring TERAS
    Zama, T
    Saito, T
    Onuki, H
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1999, 101 : 991 - 995
  • [18] Status of the High Brilliance Synchrotron Light Source BESSY - II
    BESSY, Berlin, Germany
    Proc IEEE Part Accel Conf, (713-715):
  • [19] Layout of a femtosecond x-ray source at BESSY II
    Bäcker, HJ
    Bahrdt, J
    Dürr, HA
    Durr, V
    Eberhardt, W
    Gaupp, A
    Jaeschke, E
    Holldack, K
    Khan, S
    Krämer, D
    Mertins, HC
    Peatman, WB
    Reichardt, G
    Quast, T
    Scheer, M
    Senf, F
    Wüstefeld, G
    Hertel, I
    Noack, F
    Sandner, W
    Will, I
    Zhavoronkov, N
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 836 - 838
  • [20] Beamline for calibration of transfer standard light sources in the UV and VUV regions
    Zama, T
    Saito, T
    Onuki, H
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 759 - 761