Source and detector calibration in the UV and VUV at BESSY II

被引:39
|
作者
Richter, M [1 ]
Hollandt, J [1 ]
Kroth, U [1 ]
Paustian, W [1 ]
Rabus, H [1 ]
Thornagel, R [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
D O I
10.1088/0026-1394/40/1/324
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
After the shutdown of the BESSY I electron storage ring, PTB's two normal-incidence monochromator beamlines for the calibration of radiation sources and detectors in the wavelength range from 40 nm to 400 nm were transferred to PTB's new radiometry laboratory at BESSY II. In this paper, the beamlines and their properties are briefly described. First results for the calibration of secondary source standards and detector standards at BESSY II are shown and demonstrate the successful re-establishment of the measurement capabilities. In the ultraviolet, calibration of deuterium lamps was reproduced within 1% and of silicon trap photodetectors within 0.2%.
引用
收藏
页码:S107 / S110
页数:4
相关论文
共 50 条
  • [1] Detector calibration at the PTB radiometry laboratory at BESSY
    Rabus, H
    Scholze, F
    Thornagel, R
    Ulm, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3): : 209 - 216
  • [2] Detector calibration at the PTB radiometry laboratory at BESSY
    Physikalisch-Technische, Bundesanstalt, Berlin, Germany
    Nucl Instrum Methods Phys Res Sect A, 2-3 (209-216):
  • [3] UV and VUV Calibration Capabilities at the Metrology Light Source for Solar and Atmospheric Research
    Klein, R.
    Gottwald, A.
    Kolbe, M.
    Richter, M.
    Scholze, F.
    Thornagel, R.
    Ulm, G.
    RADIATION PROCESSES IN THE ATMOSPHERE AND OCEAN (IRS2012), 2013, 1531 : 879 - 882
  • [4] PTB's radiometric scales for UV and VUV source calibration based on synchrotron radiation
    Klein, Roman
    Kroth, Simone
    Paustian, Wolfgang
    Richter, Mathias
    Thornagel, Reiner
    METROLOGIA, 2018, 55 (03) : 386 - 391
  • [5] X-ray detector calibration in the PTB radiometry laboratory at the electron storage ring BESSY II
    Beckhoff, B
    Klein, R
    Krumrey, M
    Scholze, F
    Thornagel, R
    Ulm, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2): : 480 - 483
  • [6] VUV/EUV primary standard detector facility and transfer detector calibration
    Zheng, L
    Cui, MQ
    Zhao, YD
    Zhu, J
    Zhou, KJ
    Chen, K
    Zhao, J
    Sun, LJ
    Ma, CY
    Zhou, HJ
    Huo, TL
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (04): : 430 - 434
  • [7] Source size and emittance monitoring on BESSY II
    Holldack, K
    Feikes, J
    Peatman, WB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 235 - 238
  • [8] Calibration of energy-dispersive X-ray detectors at BESSY I and BESSY II
    Scholze, F
    Thornagel, R
    Ulm, G
    METROLOGIA, 2001, 38 (05) : 391 - 395
  • [9] Ruby based detector in UV and VUV spectral region
    Aslyan, Z.
    Madatyan, K.
    Vardanyan, J.
    Tsakanov, V.
    Mikaelyan, R.
    BRILLIANT LIGHT IN LIFE AND MATERIAL SCIENCES, 2007, : 491 - +
  • [10] High accuracy calibration of the HXDS HPGe detector at the PTB radiometry laboratory at BESSY
    Kraft, S
    Scholze, F
    Thornagel, R
    Ulm, G
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 101 - 112