Low noise preamplifier design for nerve cuff electrode recording systems

被引:0
|
作者
Rieger, R [1 ]
Taylor, J [1 ]
Donaldson, N [1 ]
机构
[1] Univ Coll London, Dept Elect & Elect Engn, London, England
关键词
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
This paper discusses certain crucial issues involved in the design of a preamplifier for an implantable neuralprosthesis. The preamplifier has a nominal gain of 100, a bandwidth of 15KHz and is required to combine very low noise with low power consumption. In particular, due to the low frequencies involved, 1/f noise assumes great significance. We consider three possible architectures for the input stage of the preamplifier: (a) BICMOS and CMOS in (b) weak and (c) strong inversion. We demonstrate that although the CMOS amplifiers can approach the performance of the BICMOS circuit, this is only possible at the cost of greater power consumption and enormously increased circuit area. Against these arguments must be set the greater cost of a BICMOS process.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 50 条
  • [21] A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
    Yu, Huaiqiang
    Xiong, Wenjie
    Zhang, Hongze
    Wang, Wei
    Li, Zhihong
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2014, 23 (05) : 1025 - 1035
  • [22] A simple cuff electrode for nerve recording and stimulation in acute experiments on small animals
    Fenik, V
    Fenik, P
    Kubin, L
    JOURNAL OF NEUROSCIENCE METHODS, 2001, 106 (02) : 147 - 151
  • [23] Polymeric C-shaped cuff electrode for recording of peripheral nerve signal
    Xue, Ning
    Sun, Tao
    Tsang, Wei Mong
    Delgado-Martinez, Ignacio
    Lee, Sang-Hoon
    Sheshadri, Swathi
    Xiang, Zhuolin
    Merugu, Srinivas
    Gu, Yuandong
    Yen, Shih-Cheng
    Thakor, Nitish V.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 640 - 648
  • [24] Improvement of signal-to-interference ratio and signal-to-noise ratio in nerve cuff electrode systems
    Chu, Jun-Uk
    Song, Kang-Il
    Han, Sungmin
    Lee, Soo Hyun
    Kim, Jinseok
    Kang, Ji Yoon
    Hwang, Dosik
    Suh, Jun-Kyo Francis
    Choi, Kuiwon
    Youn, Inchan
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (06) : 943 - 967
  • [25] Novel Design of Low Noise Preamplifier for Medical Ultrasound Transducers
    Amer, Mashhour Bani
    JOURNAL OF MEDICAL SYSTEMS, 2011, 35 (01) : 71 - 77
  • [26] Novel Design of Low Noise Preamplifier for Medical Ultrasound Transducers
    Mashhour Bani Amer
    Journal of Medical Systems, 2011, 35 : 71 - 77
  • [27] Optimizing the design of bipolar nerve cuff electrodes for improved recording of peripheral nerve activity
    Sabetian, Parisa
    Popovic, Milos R.
    Yoo, Paul B.
    JOURNAL OF NEURAL ENGINEERING, 2017, 14 (03)
  • [28] LOW-NOISE PREAMPLIFIER
    LEONTEV, GE
    ARMONAVICHYUS, VP
    MIKOLAITIS, GS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1984, 27 (01) : 139 - 140
  • [29] LOW-NOISE PREAMPLIFIER
    KOKES, A
    CESKOSLOVENSKY CASOPIS PRO FYSIKU SEKCE A, 1969, 19 (02): : 256 - &
  • [30] Design, Fabrication and Modeling of a Cuff Electrode for Peripheral Nerve Stimulation
    Rodrigues, Fabio
    Mendes, Paulo
    Goncalves, Luis
    Bartek, Marian
    Mimoun, Benjamin
    Fouchard, Alexandre
    Pham, Pascale
    David, Olivier
    2013 IEEE 3RD PORTUGUESE MEETING IN BIOENGINEERING (ENBENG), 2013,