Low noise preamplifier design for nerve cuff electrode recording systems

被引:0
|
作者
Rieger, R [1 ]
Taylor, J [1 ]
Donaldson, N [1 ]
机构
[1] Univ Coll London, Dept Elect & Elect Engn, London, England
关键词
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
This paper discusses certain crucial issues involved in the design of a preamplifier for an implantable neuralprosthesis. The preamplifier has a nominal gain of 100, a bandwidth of 15KHz and is required to combine very low noise with low power consumption. In particular, due to the low frequencies involved, 1/f noise assumes great significance. We consider three possible architectures for the input stage of the preamplifier: (a) BICMOS and CMOS in (b) weak and (c) strong inversion. We demonstrate that although the CMOS amplifiers can approach the performance of the BICMOS circuit, this is only possible at the cost of greater power consumption and enormously increased circuit area. Against these arguments must be set the greater cost of a BICMOS process.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 50 条
  • [1] Design of a low-noise preamplifier for nerve cuff electrode recording
    Rieger, R
    Taylor, J
    Demosthenous, A
    Donaldson, N
    Langlois, PJ
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2003, 38 (08) : 1373 - 1379
  • [2] A low-noise preamplifier for nerve cuff electrodes
    Sahin, M
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (04) : 561 - 565
  • [3] Fascicle selective recording with a nerve cuff electrode
    Struijk, JJ
    Haugland, MK
    Thomsen, M
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 361 - 362
  • [4] A PARYLENE CUFF ELECTRODE FOR PERIPHERAL NERVE RECORDING
    Cobo, Angelica M.
    Boyajian, Barbara
    Larson, Christopher
    Scholten, Kee
    Pikov, Victor
    Meng, Ellis
    30TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2017), 2017, : 506 - 509
  • [5] Design of an adaptive interference reduction system for nerve-cuff electrode recording
    Demosthenous, A
    Taylor, J
    Triantis, IF
    Rieger, R
    Donaldson, N
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2004, 51 (04) : 629 - 639
  • [6] Low-noise Averaging Amplifier Dedicated to ENG Recording with Hexagonal Cuff Electrode
    Gouyet, Lionel
    Cathebras, Guy
    Bernard, Serge
    Soulier, Fabien
    Guiraud, David
    Bertrand, Yves
    2008 JOINT IEEE NORTH-EAST WORKSHOP ON CIRCUITS AND SYSTEMS AND TAISA CONFERENCE, 2008, : 161 - 164
  • [7] Selective recording with a multi-contact nerve cuff electrode
    Sahin, M
    Durand, DM
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 369 - 370
  • [8] Selective fascicular recording of the hypoglossal nerve using a multicontact nerve cuff electrode
    Yoo, PB
    Durand, DM
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 2172 - 2175
  • [9] The design of a low-noise preamplifier for MRI
    XueMing Cao
    DongLin Zu
    XuNa Zhao
    Yang Fan
    JiaHong Gao
    Science China Technological Sciences, 2011, 54 : 1766 - 1770
  • [10] The design of a low-noise preamplifier for MRI
    CAO XueMing ZU DongLin ZHAO XuNa FAN Yang GAO JiaHong Beijing Key Laboratory of Medical Physics and Engineering IHIP of Physics School Peking University Beijing China
    Science China(Technological Sciences), 2011, 54 (07) : 1766 - 1770