Adaptive noise reduction toward low-dose computed tomography

被引:17
|
作者
Lu, HB [1 ]
Li, X [1 ]
Li, LH [1 ]
Chen, DQ [1 ]
Xing, YX [1 ]
Hsieh, J [1 ]
Liang, ZR [1 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
关键词
noise reduction; nonstationary noise; dose reduction; computed tomography; adaptive filtering; edge-preserving smoothing; streak artifacts;
D O I
10.1117/12.480374
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An efficient noise treatment, scheme has been developed to achieve low-dose CT diagnosis based on currently available CT hardware and image reconstruction technologies. The scheme proposed includes two main parts: filtering in sinogram domain and smoothing in image domain. The acquired projection sinograms were first treated by our previously proposed Karhunen-Loeve (K-L) domain penalized weighted least-square (PWLS) filtering, which fully utilizes the prior statistical noise property and three-dimensional (3D) spatial information for an accurate restoration of the low-dose projections. To treat the streak artifacts due to photon starvation, we also incorporated an adaptive filtering into our PWLS framework, which selectively smoothes those channels contributing most to the streak artifacts. After the sinogram filtering, the image was reconstructed by the conventional filtered backprojection (FBP) method. The image is assumed as piecewise regions each has a unique texture. Therefore, an edge-preserving. smoothing (EPS) with locally-adaptive parameters to the noise variation was applied for further noise reduction in image domain. Experimental phantom projections acquired by A GE spiral computed tomography (CT) scanner under 10 mAs tube current were used to evaluate the proposed smoothing scheme. The reconstructed imaged demonstrated that the smoothing scheme with appropriate control parameters provides a significant improvement on noise suppression without sacrificing the spatial resolution.
引用
收藏
页码:759 / 766
页数:8
相关论文
共 50 条
  • [31] Subsolid Pulmonary Nodules in Low-Dose Computed Tomography
    Hekmat, K.
    Bruns, C. J.
    CHIRURG, 2018, 89 (12): : 1008 - 1008
  • [32] Lung Cancer Screening With Low-Dose Computed Tomography
    Reck, Martin
    Dettmer, Sabine
    Kauczor, Hans-Ulrich
    Kaaks, Rudolf
    Reinmuth, Niels
    Vogel-Claussen, Jens
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2023, 120 (23): : 387 - +
  • [33] Low-Dose Cardiovascular Computed Tomography: Where are the Limits?
    Paul Schoenhagen
    Carla M. Thompson
    Sandra S. Halliburton
    Current Cardiology Reports, 2012, 14 : 17 - 23
  • [34] Low-Dose Computed Tomography Screening for Lung Cancer
    Welch, Laura S.
    Madtes, David
    Ringen, Knut
    ANNALS OF INTERNAL MEDICINE, 2015, 162 (06) : 459 - 460
  • [35] A sinogram denoising algorithm for low-dose computed tomography
    Davood Karimi
    Pierre Deman
    Rabab Ward
    Nancy Ford
    BMC Medical Imaging, 16
  • [36] Low-Dose Cardiovascular Computed Tomography: Where Are the Limits?
    Schoenhagen, Paul
    Thompson, Carla M.
    Halliburton, Sandra S.
    CURRENT CARDIOLOGY REPORTS, 2012, 14 (01) : 17 - 23
  • [37] Lung cancer screening with low-dose computed tomography
    Seijo Maceiras, Luis M.
    MEMO-MAGAZINE OF EUROPEAN MEDICAL ONCOLOGY, 2014, 7 (01) : 6 - 9
  • [38] Lung cancer screening with low-dose computed tomography
    Hartman, TE
    Swensen, SJ
    SEMINARS IN ROENTGENOLOGY, 2003, 38 (01) : 34 - 38
  • [39] Low-dose computed tomography in prior asbestos workers
    Roberts, H.
    LUNG CANCER, 2006, 54 : S3 - S3
  • [40] Lung Cancer Screening With Low-Dose Computed Tomography
    Loebig, Stephanie
    Haegele, Patricia
    Seizer, Peter
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2023, 120 (41):