Adaptive noise reduction toward low-dose computed tomography

被引:17
|
作者
Lu, HB [1 ]
Li, X [1 ]
Li, LH [1 ]
Chen, DQ [1 ]
Xing, YX [1 ]
Hsieh, J [1 ]
Liang, ZR [1 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
关键词
noise reduction; nonstationary noise; dose reduction; computed tomography; adaptive filtering; edge-preserving smoothing; streak artifacts;
D O I
10.1117/12.480374
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An efficient noise treatment, scheme has been developed to achieve low-dose CT diagnosis based on currently available CT hardware and image reconstruction technologies. The scheme proposed includes two main parts: filtering in sinogram domain and smoothing in image domain. The acquired projection sinograms were first treated by our previously proposed Karhunen-Loeve (K-L) domain penalized weighted least-square (PWLS) filtering, which fully utilizes the prior statistical noise property and three-dimensional (3D) spatial information for an accurate restoration of the low-dose projections. To treat the streak artifacts due to photon starvation, we also incorporated an adaptive filtering into our PWLS framework, which selectively smoothes those channels contributing most to the streak artifacts. After the sinogram filtering, the image was reconstructed by the conventional filtered backprojection (FBP) method. The image is assumed as piecewise regions each has a unique texture. Therefore, an edge-preserving. smoothing (EPS) with locally-adaptive parameters to the noise variation was applied for further noise reduction in image domain. Experimental phantom projections acquired by A GE spiral computed tomography (CT) scanner under 10 mAs tube current were used to evaluate the proposed smoothing scheme. The reconstructed imaged demonstrated that the smoothing scheme with appropriate control parameters provides a significant improvement on noise suppression without sacrificing the spatial resolution.
引用
收藏
页码:759 / 766
页数:8
相关论文
共 50 条
  • [1] Noise Simulation for Low-dose Computed Tomography
    Fan, Yi
    Zamyatin, Alexander A.
    Nakanishi, Satoru
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3641 - 3643
  • [2] Noise reduction for low-dose X-ray computed tomography with fuzzy filter
    Gui, Zhi-guo
    Liu, Yi
    OPTIK, 2012, 123 (13): : 1207 - 1211
  • [3] Adaptive Image Denoising Approach for Low-Dose Computed Tomography
    Elyamani, Haneen A.
    El-Seoud, Samir A.
    Kudo, Hiroyuki
    Rashed, Essam A.
    2017 12TH INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING AND SYSTEMS (ICCES), 2017, : 66 - 72
  • [4] Value-Based Noise Reduction for Low-Dose Dual-Energy Computed Tomography
    Balda, Michael
    Heismann, Bjoern
    Hornegger, Joachim
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT III, 2010, 6363 : 547 - 554
  • [5] Noise reduction in low-dose positron emission tomography with adaptive parameter estimation in sinogram domain
    Kim, Kyu Bom
    Kim, Yeonkyeong
    Kim, Kyuseok
    Lee, Su Hwan
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (10) : 4127 - 4133
  • [6] A Comparative Study of Noise-Reduction Algorithms for Low-Dose Cone-Beam Computed Tomography
    Mukherjee, S.
    Yao, W.
    MEDICAL PHYSICS, 2015, 42 (06) : 3201 - 3201
  • [7] LOW-DOSE COMPUTED-TOMOGRAPHY
    GHOLKAR, A
    HART, CW
    MOTT, D
    GILLESPIE, JE
    ISHERWOOD, I
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 773 - 773
  • [8] Noise reduction of low-dose computed tomography using the multi-resolution total variation minimization algorithm
    Shih, Cheng-Ting
    Chang, Shu-Jun
    Liu, Yan-Lin
    Wu, Jay
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [9] Radiation dose reduction in hepatic multidetector computed tomography with a novel adaptive noise reduction filter
    Funama, Yoshinori
    Awai, Kazuo
    Miyazaki, Osamu
    Goto, Taiga
    Nakayama, Yoshiharu
    Shimamura, Masamitchi
    Hiraishi, Kumiko
    Hori, Shinichi
    Yamashita, Yasuyuki
    RADIATION MEDICINE, 2008, 26 (03): : 171 - 177
  • [10] Radiation dose reduction in hepatic multidetector computed tomography with a novel adaptive noise reduction filter
    Yoshinori Funama
    Kazuo Awai
    Osamu Miyazaki
    Taiga Goto
    Yoshiharu Nakayama
    Masamitchi Shimamura
    Kumiko Hiraishi
    Shinichi Hori
    Yasuyuki Yamashita
    Radiation Medicine, 2008, 26 : 171 - 177