摘要
Sentinel lymph node (SLN) biopsy has emerged as an effective diagnostic tool in axillary staging in breast cancer. The commonly used technique employs isosulfan blue/patent blue V combined with radioactive colloid tracer. Methylene blue (MB) is a less expensive and readily available alternative dye. The study evaluated the safety and efficacy of MB in SLN localization. A retrospective study of 329 patients with early breast cancer who had SLN localization as part of an ethically approved prospective evaluation study of SLN localization technique was carried out. Lymph node positive, tumors > 2 cm on clinical and radiological evaluation, those with previous breast and axillary surgery, neo-adjuvant chemotherapy were excluded from the study. One hundred seventy three patients underwent SLN localization using 1 mL of 1% MB, and a combined MB-radio colloid tracer technique was used in the other 156 patients. Allocation to the groups was by simple randomization. Injection of the dye and radioisotope was into the subdermal plane in the sub-areolar region. Patients underwent breast conservation surgery or mastectomy with SLN directed four node axillary sampling +/- axillary clearance. The lymph node was examined by standard microscopy. There were no reported complications with the use of MB aside from temporary tattooing. The technique failed in eight patients giving an identification rate of 97.6%. Ten of the 258 (3.9%) patients had false-negative SLN, with negative predictive value of 96.1%, sensitivity of predicting further axillary disease of 73%, specificity of 87.3%, and overall accuracy of 85.7%. Reported adverse reaction to isosulfan blue/patent blue V varied from minor to severe anaphylactic reactions (1-3%) requiring vigorous resuscitation. Subdermal sub-areolar injection of MB is safe and effective readily available dye for SLN localization in axillary staging of breast cancer with no major adverse reaction.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [41] USE OF BLUE DYE IN SENTINEL LYMPH NODE BIOPSY: TIME TO REEVALUATE
    Wong, G. Y. M.
    Rippy, E.
    Bochner, M.
    Ainsworth, R.
    BREAST, 2014, 23 (04): : S3 - S3
  • [42] Sentinel lymph node identification by blue dye in patients with breast carcinoma
    Bakhtiar, Nighat
    Jaleel, Farhat
    Moosa, Foad Ali
    Qureshi, Naeem Akhtar
    Jawaid, Masood
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2016, 32 (02) : 448 - 451
  • [43] Blue dye is sufficient for sentinel lymph node biopsy in breast cancer
    Ang, C. H.
    Tan, M. Y.
    Teo, C.
    Seah, D. W.
    Chen, J. C.
    Chan, M. Y. P.
    Tan, E. Y.
    BRITISH JOURNAL OF SURGERY, 2014, 101 (04) : 383 - 389
  • [44] Anaphylaxis to isosulfan blue dye during sentinel lymph node biopsy
    Sandhu, S
    Farag, E
    Argalious, M
    JOURNAL OF CLINICAL ANESTHESIA, 2005, 17 (08) : 633 - 635
  • [45] Anaphylactic response to blue dye during sentinel lymph node biopsy
    Bezu, Corinne
    Coutant, Charles
    Salengro, Anne
    Darai, Emile
    Rouzier, Roman
    Uzan, Serge
    SURGICAL ONCOLOGY-OXFORD, 2011, 20 (01): : E55 - E59
  • [46] Methylene blue dye versus combined dye-radioactive tracer technique for sentinel lymph node localisation in early breast cancer
    Varghese, P.
    Mostafa, A.
    Abdel-Rahman, A. T.
    Akberali, S.
    Gattuso, J.
    Canizales, A.
    Wells, C. A.
    Carpenter, R.
    EJSO, 2007, 33 (02): : 147 - 152
  • [47] Assessment of the efficacy and oncological safety of sentinel lymph node biopsy in node-negative breast cancer using methylene blue dye
    Elahmady, Rania
    Mohsen, Sherief M.
    EGYPTIAN JOURNAL OF SURGERY, 2018, 37 (01): : 31 - 39
  • [48] Clinical Efficacy of Sentinel Lymph Node Biopsy Using Methylene Blue Dye in Clinically Node-Negative Papillary Thyroid Carcinoma
    Yong Bae Ji
    Keon Joong Lee
    Yong Soo Park
    Sang Mo Hong
    Seung Sam Paik
    Kyung Tae
    Annals of Surgical Oncology, 2012, 19 : 1868 - 1873
  • [49] Clinical Efficacy of Sentinel Lymph Node Biopsy Using Methylene Blue Dye in Clinically Node-Negative Papillary Thyroid Carcinoma
    Ji, Yong Bae
    Lee, Keon Joong
    Park, Yong Soo
    Hong, Sang Mo
    Paik, Seung Sam
    Tae, Kyung
    ANNALS OF SURGICAL ONCOLOGY, 2012, 19 (06) : 1868 - 1873
  • [50] Fluorescence Imaging Using Methylene Blue Sentinel Lymph Node Biopsy in Melanoma
    Cwalinski, Tomasz
    Skokowski, Jaroslaw
    Polom, Wojciech
    Marano, Luigi
    Swierblewski, Maciej
    Drucis, Kamil
    Roviello, Giandomenico
    Cwalina, Natalia
    Kalinowski, Leszek
    Roviello, Franco
    Polom, Karol
    SURGICAL INNOVATION, 2022, 29 (04) : 503 - 510