Methylene blue dye - A safe and effective alternative for sentinel lymph node localization

被引:89
|
作者
Varghese, Philip [1 ]
Abdel-Rahman, Alaa Talaat. [1 ]
Akberali, Samira [1 ]
Mostafa, Azad [1 ]
Gattuso, Jennifer May. [1 ]
Carpenter, Robert [1 ]
机构
[1] Queen Mary Univ London, St Bartholomews Hosp, Canc Serv, Breast & Endocrine Unit, London EC1A 7BE, England
来源
BREAST JOURNAL | 2008年 / 14卷 / 01期
关键词
allergic reaction; isosulfan blue; methylene blue; patent blue V; sentinel lymph node biopsy;
D O I
10.1111/j.1524-4741.2007.00519.x
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Sentinel lymph node (SLN) biopsy has emerged as an effective diagnostic tool in axillary staging in breast cancer. The commonly used technique employs isosulfan blue/patent blue V combined with radioactive colloid tracer. Methylene blue (MB) is a less expensive and readily available alternative dye. The study evaluated the safety and efficacy of MB in SLN localization. A retrospective study of 329 patients with early breast cancer who had SLN localization as part of an ethically approved prospective evaluation study of SLN localization technique was carried out. Lymph node positive, tumors > 2 cm on clinical and radiological evaluation, those with previous breast and axillary surgery, neo-adjuvant chemotherapy were excluded from the study. One hundred seventy three patients underwent SLN localization using 1 mL of 1% MB, and a combined MB-radio colloid tracer technique was used in the other 156 patients. Allocation to the groups was by simple randomization. Injection of the dye and radioisotope was into the subdermal plane in the sub-areolar region. Patients underwent breast conservation surgery or mastectomy with SLN directed four node axillary sampling +/- axillary clearance. The lymph node was examined by standard microscopy. There were no reported complications with the use of MB aside from temporary tattooing. The technique failed in eight patients giving an identification rate of 97.6%. Ten of the 258 (3.9%) patients had false-negative SLN, with negative predictive value of 96.1%, sensitivity of predicting further axillary disease of 73%, specificity of 87.3%, and overall accuracy of 85.7%. Reported adverse reaction to isosulfan blue/patent blue V varied from minor to severe anaphylactic reactions (1-3%) requiring vigorous resuscitation. Subdermal sub-areolar injection of MB is safe and effective readily available dye for SLN localization in axillary staging of breast cancer with no major adverse reaction.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [21] Sentinel Lymph Node Biopsy in Early Breast Cancer Using Methylene Blue Dye Alone: a Safe, Simple, and Cost-Effective Procedure in Resource-Constrained Settings
    Devarakonda, Sreekar
    Thomas, Shawn Sam
    Sen, Supriya
    Thomas, Varghese
    Karuppusami, Reka
    Cherian, Anish Jacob
    Ramakant, Pooja
    Abraham, Deepak Thomas
    Jacob, Paul Mazhuvanchary
    INDIAN JOURNAL OF SURGICAL ONCOLOGY, 2021, 12 (01) : 210 - 217
  • [22] Dual tracing modality of indocyanine green and methylene blue is an alternative option for sentinel lymph node biopsy
    Zhu, Q.
    Wang, J.
    Yin, Z.
    Xie, F.
    Chen, R.
    You, S.
    Jiang, C.
    Li, S.
    Li, Y.
    Zha, X.
    BREAST, 2019, 44 : S121 - S122
  • [23] Combined use of indocyanine green fluorescence and methylene blue dye versus methylene blue dye alone for sentinel lymph node biopsy in breast cancer patients.
    Wang, Shu
    Guo, Jiajia
    Yang, Deqi
    Cao, Yingming
    Tong, Fuzhong
    Zhou, Bo
    Liu, Peng
    Liu, Hongjun
    Cheng, Lin
    Liu, Miao
    Yang, Houpu
    Xie, Fei
    Wang, Siyuan
    JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (15)
  • [24] Intraoperative sentinel lymph node positivity by methylene blue dye and its association with other dissected lymph node by histopathological examination in colorectal cancer
    Bharathi, M. Thangasamy
    Meena, R.
    Jain, S.
    ANNALS OF ONCOLOGY, 2016, 27 : 87 - 88
  • [25] Methylene blue 1% as a sensitive and safe alternative for sentinel lymph node biopsy in early stage breast cancer: Results of a large pilot study
    Khallaf, Emad
    Abdoon, Mohamed
    Lotfy, Abdelrahman
    Abdalaziz, Youmna
    Kamal, Rasha
    Attia, Hanaa
    BREAST JOURNAL, 2019, 25 (05): : 1017 - 1019
  • [26] Carbon dye as an adjunct to isosulfan blue dye for sentinel lymph node dissection
    Lucci, A
    Turner, RR
    Morton, DL
    SURGERY, 1999, 126 (01) : 48 - 53
  • [27] Methylene blue alone for identification of the sentinel lymph node in breast carcinoma
    Golshan, M
    Nakhlis, F
    ANNALS OF SURGICAL ONCOLOGY, 2006, 13 (02) : 41 - 41
  • [28] Intraoperative methylene blue sentinel lymph node mapping in colorectal cancer
    Chan, Siew H.
    Ng, Colin
    Looi, Lai M.
    ANZ JOURNAL OF SURGERY, 2008, 78 (09) : 775 - 779
  • [29] Localization of the sentinel lymph node in tongue VX2 carcinoma via indirect CT lymphography combined with methylene blue dye injection
    Wu, Haitao
    Ying, Haiyue
    Xi, Xiuyian
    Shen, Na
    Shu, Yilai
    Hoffman, Matthew R.
    Rieves, Adam
    Sha, Yian
    Zhou, Liang
    ACTA OTO-LARYNGOLOGICA, 2010, 130 (04) : 503 - 510
  • [30] Sentinel lymph node in colon cancer. methylene Blue® or Nanocoll®?
    Hernando, R.
    Serra, X.
    Bombardo, J.
    Casalots, A.
    Martin, J. C.
    Mena, E.
    Junquera, F.
    Pericay, C.
    Navarro, S.
    ANNALS OF SURGICAL ONCOLOGY, 2008, 15 : 50 - 50