Methylene blue dye - A safe and effective alternative for sentinel lymph node localization

被引:89
|
作者
Varghese, Philip [1 ]
Abdel-Rahman, Alaa Talaat. [1 ]
Akberali, Samira [1 ]
Mostafa, Azad [1 ]
Gattuso, Jennifer May. [1 ]
Carpenter, Robert [1 ]
机构
[1] Queen Mary Univ London, St Bartholomews Hosp, Canc Serv, Breast & Endocrine Unit, London EC1A 7BE, England
来源
BREAST JOURNAL | 2008年 / 14卷 / 01期
关键词
allergic reaction; isosulfan blue; methylene blue; patent blue V; sentinel lymph node biopsy;
D O I
10.1111/j.1524-4741.2007.00519.x
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Sentinel lymph node (SLN) biopsy has emerged as an effective diagnostic tool in axillary staging in breast cancer. The commonly used technique employs isosulfan blue/patent blue V combined with radioactive colloid tracer. Methylene blue (MB) is a less expensive and readily available alternative dye. The study evaluated the safety and efficacy of MB in SLN localization. A retrospective study of 329 patients with early breast cancer who had SLN localization as part of an ethically approved prospective evaluation study of SLN localization technique was carried out. Lymph node positive, tumors > 2 cm on clinical and radiological evaluation, those with previous breast and axillary surgery, neo-adjuvant chemotherapy were excluded from the study. One hundred seventy three patients underwent SLN localization using 1 mL of 1% MB, and a combined MB-radio colloid tracer technique was used in the other 156 patients. Allocation to the groups was by simple randomization. Injection of the dye and radioisotope was into the subdermal plane in the sub-areolar region. Patients underwent breast conservation surgery or mastectomy with SLN directed four node axillary sampling +/- axillary clearance. The lymph node was examined by standard microscopy. There were no reported complications with the use of MB aside from temporary tattooing. The technique failed in eight patients giving an identification rate of 97.6%. Ten of the 258 (3.9%) patients had false-negative SLN, with negative predictive value of 96.1%, sensitivity of predicting further axillary disease of 73%, specificity of 87.3%, and overall accuracy of 85.7%. Reported adverse reaction to isosulfan blue/patent blue V varied from minor to severe anaphylactic reactions (1-3%) requiring vigorous resuscitation. Subdermal sub-areolar injection of MB is safe and effective readily available dye for SLN localization in axillary staging of breast cancer with no major adverse reaction.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [1] Methylene blue dye as an alternative to isosulfan blue dye for sentinel lymph node localization
    Simmons, RM
    Brennan, M
    Christos, P
    Thevalrajah, S
    Smith, SR
    Osborne, M
    ANNALS OF SURGICAL ONCOLOGY, 2002, 9 (01) : S62 - S62
  • [2] Methylene Blue Dye as an Alternative to Isosulfan Blue Dye for Sentinel Lymph Node Localization
    Rache Simmons
    Sarmela Thevarajah
    Meghan B. Brennan
    Paul Christos
    Michael Osborne
    Annals of Surgical Oncology, 2003, 10 : 242 - 247
  • [3] Methylene blue dye as an alternative to isosulfan blue dye for sentinel lymph node localization
    Simmons, R
    Thevarajah, S
    Brennan, MB
    Christos, P
    Osborne, M
    ANNALS OF SURGICAL ONCOLOGY, 2003, 10 (03) : 242 - 247
  • [4] Methylene Blue Dye-Related Changes in the Breast After Sentinel Lymph Node Localization
    Kang, Seok Seon
    Han, Boo-Kyung
    Ko, Eun Young
    Shin, Jung-Hee
    Cho, Eun Yoon
    Lee, Jeong Eon
    Nam, Seok Jin
    Yang, Jung-Hyun
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (12) : 1711 - 1721
  • [5] Can methylene blue dye be used as an alternative to patent blue dye to find the sentinel lymph node in breast cancer surgery?
    Fattahi, Asieh Sadat
    Tavassoli, Alireza
    Rohbakhshfar, Omid
    Sadeghi, Ramin
    Abdollahi, Abbas
    Forghani, Mohammad Naser
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2014, 19 (10): : 918 - 922
  • [6] Localization of the Sentinel Lymph Node in Melanoma Without Blue Dye
    Hu, Yinin
    Melmer, Patrick D.
    Slingluff, Craig L.
    ANNALS OF SURGERY, 2016, 263 (03) : 588 - 592
  • [7] Combined Methylene Blue Dye and Radioactive Tracer Technique for Sentinel Lymph Node Localization in Early Breast Cancer
    Tahmasebit, Sedigheh
    Haghighifard, Mohammad
    Talei, Abdolrasoul
    MIDDLE EAST JOURNAL OF CANCER, 2010, 1 (04) : 155 - 158
  • [8] Methylene Blue Dye, an Accurate Dye for Sentinel Lymph Node Identification in Early Breast Cancer
    Mathelin, Carole
    Croce, Sabrina
    Brasse, David
    Gairard, Beatrice
    Gharbi, Mouslim
    Andriamisandratsoa, Norosoa
    Bekaert, Virgile
    Francis, Ziad
    Guyonnet, Jean-Louis
    Huss, Daniel
    Salvador, Samuel
    Schaeffer, Roland
    Grucker, Daniel
    Marin, Cristi
    Bellocq, Jean-Pierre
    ANTICANCER RESEARCH, 2009, 29 (10) : 4119 - 4125
  • [9] Evaluation of Sentinel Lymph Node Biopsy with Methylene Blue Dye in Early Carcinoma Breast
    Sohail, Ahmad
    Sohail, Muhammad
    Asim, Muhammad
    Shakir, Javed
    Durrani, Khalid M.
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2010, 4 (03): : 233 - 235
  • [10] Adverse skin lesions after methylene blue injections for sentinel lymph node localization
    Stradling, B
    Aranha, G
    Gabram, S
    AMERICAN JOURNAL OF SURGERY, 2002, 184 (04): : 350 - 352