Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease

被引:205
|
作者
Leber, Alexander W.
Johnson, Thorsten
Becker, Alexander
von Ziegler, Franz
Tittus, Janine
Nikolaou, Konstantin
Reiser, Maximilian
Steinbeck, Gerhard
Becker, Christoph R.
Knez, Andreas
机构
[1] Univ Munich, Dept Cardiol, Med Klin 1, D-81377 Munich, Germany
[2] Univ Munich, Dept Clin Radiol, Munich, Germany
关键词
duat-source CT; computed tomography; coronary artery disease; multi-stice CT;
D O I
10.1093/eurheartj/ehm294
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The aim of the present study was to assess the clinical performance of a dual X-ray source multi-slice CT (MSCT) with high temporal resolution to assess the coronary status in patients with an intermediate pretest likelihood for significant coronary artery disease (CAD) without using negative chronotropic pretreatment. Methods and results Dual-source CT (DSCT) angiography (Siemens Definition) was performed in 90 patients with an intermediate Likelihood for CAD who were referred for invasive coronary angiography. DSCT generated data sets with diagnostic image quality in 88 of the overall 90 patients. In six of seven patients with atria[ fibrillation and in 46 of 48 patients with heart rates (HR) >65 b.p.m. image quality was diagnostic. In 20 of 21 patients with at least one stenosis >50% (sensitivity 95%) were correctly identified by DSCT-angiography. In 60 of 67 patients, a lesion >50% was correctly excluded (specificity 90%; positive predictive value 74%). The accuracy to detect patients with coronary stenoses >50% (sensitivity 92 vs. 100%; specificity 88 vs. 91%) was not significantly different among patients with HR >65 b.p.m. (n = 46) and <65 b.p.m. The concordance of DSCT-derived stenosis quantification showed good correlation (r = 0.76; P < 0.001) to quantitative coronary angiography with a slight trend to overestimate the stenosis degree. Conclusion DSCT is a non-invasive tool that allows to accurately rule out coronary stenoses in patients with an intermediate pretest likelihood for CAD, independent of the HR.
引用
收藏
页码:2354 / 2360
页数:7
相关论文
共 50 条
  • [21] Accuracy of dual-source CT to identify coronary artery stenoses in patients with atrial fibrillation: comparison with invasive coronary angiography
    Marwan, M.
    Schepis, T.
    Renz, A.
    Pflederer, T.
    Ropers, D.
    Daniel, W. G.
    Achenbach, S.
    EUROPEAN HEART JOURNAL, 2009, 30 : 205 - 205
  • [22] Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols
    Lisan A. Neefjes
    Alexia Rossi
    Tessa S. S. Genders
    Koen Nieman
    Stella L. Papadopoulou
    Anoeshka S. Dharampal
    Carl J. Schultz
    Annick C. Weustink
    Marcel L. Dijkshoorn
    Gert-Jan R. ten Kate
    Admir Dedic
    Marcel van Straten
    Filippo Cademartiri
    M. G. Myriam Hunink
    Gabriël P. Krestin
    Pim J. de Feyter
    Nico R. Mollet
    European Radiology, 2013, 23 : 614 - 622
  • [23] Dual-source CT coronary angiography: factors determining image quality and diagnostic accuracy
    Yerramasu, A.
    Venuraju, S.
    Atwal, S.
    Goodman, D.
    Lipkin, D.
    Lahiri, A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A71 - A71
  • [24] Detection of malignant right coronary artery anomaly by multi-slice CT coronary angiography
    Dirksen, M. S.
    Bax, J. J.
    Blom, N. A.
    Schalij, M. J.
    Jukema, W. J.
    Vliegen, H. W.
    van der Wall, E. E.
    de Roos, A.
    Lamb, H. J.
    EUROPEAN RADIOLOGY, 2002, 12 (Suppl 3) : S177 - S180
  • [25] Detection of malignant right coronary artery anomaly by multi-slice CT coronary angiography
    M. Dirksen
    J. Bax
    N. Blom
    M. Schalij
    W. Jukema
    H. Vliegen
    E. van der Wall
    A. de Roos
    H. Lamb
    European Radiology, 2002, 12 : S177 - S180
  • [26] Prevalence and morphology of coronary artery ectasia with dual-source CT coronary angiography
    Sebastian Leschka
    Paul Stolzmann
    Hans Scheffel
    Simon Wildermuth
    André Plass
    Michele Genoni
    Borut Marincek
    Hatem Alkadhi
    European Radiology, 2008, 18
  • [27] Coronary artery fistula in adults: evaluation with dual-source CT coronary angiography
    Zhou, K.
    Kong, L.
    Wang, Y.
    Li, S.
    Song, L.
    Wang, Z.
    Wu, W.
    Chen, J.
    Wang, Y.
    Jin, Z.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1049):
  • [28] Prevalence and morphology of coronary artery ectasia with dual-source CT coronary angiography
    Leschka, Sebastian
    Stolzmann, Paul
    Scheffel, Hans
    Wildermuth, Simon
    Plass, Andre
    Genoni, Michele
    Marincek, Borut
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2008, 18 (12) : 2776 - 2784
  • [29] Multi-slice and Dual-source CT in Cardiac Imaging
    Thali, M.
    KARDIOLOGE, 2008, 2 (04): : 293 - 293
  • [30] Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease
    Johnson, Thorsten R. C.
    Nikolaou, Konstantin
    Busch, Stephanie
    Leber, Alexander W.
    Becker, Alexander
    Wintersperger, Bernd J.
    Rist, Carsten
    Knez, Andreas
    Reiser, Maximilian F.
    Becker, Christoph R.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (10) : 684 - 691