Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease

被引:205
|
作者
Leber, Alexander W.
Johnson, Thorsten
Becker, Alexander
von Ziegler, Franz
Tittus, Janine
Nikolaou, Konstantin
Reiser, Maximilian
Steinbeck, Gerhard
Becker, Christoph R.
Knez, Andreas
机构
[1] Univ Munich, Dept Cardiol, Med Klin 1, D-81377 Munich, Germany
[2] Univ Munich, Dept Clin Radiol, Munich, Germany
关键词
duat-source CT; computed tomography; coronary artery disease; multi-stice CT;
D O I
10.1093/eurheartj/ehm294
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The aim of the present study was to assess the clinical performance of a dual X-ray source multi-slice CT (MSCT) with high temporal resolution to assess the coronary status in patients with an intermediate pretest likelihood for significant coronary artery disease (CAD) without using negative chronotropic pretreatment. Methods and results Dual-source CT (DSCT) angiography (Siemens Definition) was performed in 90 patients with an intermediate Likelihood for CAD who were referred for invasive coronary angiography. DSCT generated data sets with diagnostic image quality in 88 of the overall 90 patients. In six of seven patients with atria[ fibrillation and in 46 of 48 patients with heart rates (HR) >65 b.p.m. image quality was diagnostic. In 20 of 21 patients with at least one stenosis >50% (sensitivity 95%) were correctly identified by DSCT-angiography. In 60 of 67 patients, a lesion >50% was correctly excluded (specificity 90%; positive predictive value 74%). The accuracy to detect patients with coronary stenoses >50% (sensitivity 92 vs. 100%; specificity 88 vs. 91%) was not significantly different among patients with HR >65 b.p.m. (n = 46) and <65 b.p.m. The concordance of DSCT-derived stenosis quantification showed good correlation (r = 0.76; P < 0.001) to quantitative coronary angiography with a slight trend to overestimate the stenosis degree. Conclusion DSCT is a non-invasive tool that allows to accurately rule out coronary stenoses in patients with an intermediate pretest likelihood for CAD, independent of the HR.
引用
收藏
页码:2354 / 2360
页数:7
相关论文
共 50 条
  • [11] Comparison of dual-source ct coronary angiography and conventional coronary angiography for detecting coronary artery disease
    Xu, Yi
    Tang, Lijun
    Zhu, Xiaomei
    Xu, Hai
    Tang, Jinhua
    Yang, Zhijian
    Wang, Liansheng
    Wang, Dehang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 : 75 - 81
  • [12] Diagnostic Accuracy of 64-Slice Multislice Computed Tomographic Coronary Angiography in Patients With an Intermediate Pretest Likelihood for Coronary Artery Disease (vol 105, pg 302, 2010)
    Boogers, Mark J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (06): : 910 - 910
  • [13] Diagnostic accuracy of multi slice CT coronary angiography in males and females for the detection of obstructive coronary artery disease
    Dharampal, A. S.
    Weustink, A. C.
    Rossi, A.
    Neefjes, L. A. E.
    Papadopoulou, S. L.
    Chen, C.
    Mollet, N. R. A.
    Boersma, E. H.
    Krestin, G. P.
    De Feyter, P. J.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A44 - A44
  • [14] Detection of coronary artery anomalies by dual-source CT coronary angiography
    Cheng, Z.
    Wang, X.
    Duan, Y.
    Wu, L.
    Wu, D.
    Liang, C.
    Liu, C.
    Xu, Z.
    CLINICAL RADIOLOGY, 2010, 65 (10) : 815 - 822
  • [15] Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography
    Zhang, Jian-Jun
    Liu, Tie
    Feng, Yue
    Wu, Wei-Feng
    Mou, Cai-Yun
    Zhai, Li-Hao
    KOREAN JOURNAL OF RADIOLOGY, 2011, 12 (04) : 416 - 423
  • [16] Diagnostic accuracy of dual-source CT coronary angiography in patients with atrial fibrillation: Meta analysis
    Sun, Gang
    Li, Min
    Jiang, Zhi-wei
    Xu, Lin
    Peng, Zhao-hui
    Ding, Juan
    Li, Li
    Jin, Zhi-tao
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (10) : 1749 - 1754
  • [17] Diagnostic accuracy of 16-slice CT coronary angiography in the evaluation of coronary artery disease
    Soon, K. H.
    Chaitowitz, I.
    Cox, N.
    MacGregor, L.
    Eccleston, D.
    Bell, K. W.
    Kelly, A-M
    Lim, Y. L.
    AUSTRALASIAN RADIOLOGY, 2007, 51 (04): : 365 - 369
  • [18] MULTICENTER EVALUATION OF DUAL SOURCE CT CORONARY ANGIOGRAPHY IN PATIENTS WITH INTERMEDIATE LIKELIHOOD OF CORONARY ARTERY STENOSES (MEDIC): ACCURACY FOR THE DETECTION OF INDIVIDUALS WITH SIGNIFICANT CORONARY ARTERY STENOSES
    Achenbach, Stephan
    Schuhbaeck, Annika
    Marwan, Mohamed
    Bathina, Ravi
    Ovrehus, Kristian
    Anders, Katharina
    Hoffmann, Udo
    Abbara, Suhny
    Aulbach, Peter
    Ropers, Dieter
    Pflederer, Tobias
    Becker, Christoph
    Berman, Daniel
    Hausleiter, Joerg
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1337 - E1337
  • [19] Role of multi-slice CT coronary angiography in evaluating the different patterns of coronary artery disease in patients with unstable angina
    Niazi, Gamal Eldine M.
    Elia, Remon Z.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2015, 46 (03): : 605 - 614
  • [20] Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols
    Neefjes, Lisan A.
    Rossi, Alexia
    Genders, Tessa S. S.
    Nieman, Koen
    Papadopoulou, Stella L.
    Dharampal, Anoeshka S.
    Schultz, Carl J.
    Weustink, Annick C.
    Dijkshoorn, Marcel L.
    ten Kate, Gert-Jan R.
    Dedic, Admir
    van Straten, Marcel
    Cademartiri, Filippo
    Hunink, M. G. Myriam
    Krestin, Gabriel P.
    de Feyter, Pim J.
    Mollet, Nico R.
    EUROPEAN RADIOLOGY, 2013, 23 (03) : 614 - 622