Transition edge sensor-based detector: from X-ray to γ-ray

被引:0
|
作者
Zhang, Shuo [1 ]
Xia, Jing-Kai [1 ]
Sun, Tao [2 ]
Wu, Wen-Tao [2 ]
Wu, Bing-Jun [2 ]
Wang, Yong-Liang [2 ]
Cantor, Robin [3 ]
Han, Ke [4 ,5 ]
Zhou, Xiao-Peng [6 ]
Liu, Hao-Ran [7 ]
Fan, Fu-You [7 ]
Guo, Si-Ming [7 ]
Liang, Jun-Cheng [7 ]
Li, De-Hong [7 ]
Song, Yan-Ru [1 ]
Ju, Xu-Dong [1 ]
Fu, Qiang [1 ]
Liu, Zhi [1 ]
机构
[1] ShanghaiTech Univ, Ctr Transformat Sci, Shanghai 201210, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Shanghai 200050, Peoples R China
[3] STAR Cryoelect, 25-A Bisbee Court, Santa Fe, NM 87508 USA
[4] Shanghai Jiao Tong Univ, Shanghai Lab Particle Phys & Cosmol, INPAC, Shanghai 200240, Peoples R China
[5] Shanghai Jiao Tong Univ, Dept Phys & Astron, Shanghai 200240, Peoples R China
[6] Beihang Univ, Sch Phys, Beijing 100191, Peoples R China
[7] Natl Inst Metrol, Div Ionizing Radiat, NIM, 18 Bei San Huan Dong Lu, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
Synchrotron radiation instrumentation; X-ray spectrometers; Cryogenic detectors; Transition edge sensor; SPECTROSCOPY; SPECTROMETER; CALORIMETER;
D O I
10.1007/s41365-022-01071-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A transition edge sensor (TES) is extremely sensitive to changes in temperature, and combined with a high-Z metal of a certain thickness, it can realize high-energy resolution measurements of particles such as X-rays. X-rays with energies below 10 keV have a weak penetrating ability, hence, only gold or bismuth of a few micrometers in thickness can guarantee a quantum efficiency higher than 70%. Therefore, the entire structure of the TES X-ray detector in this energy range can be realized using a microfabrication process. However, for X-rays or gamma-rays from 10 keV to 200 keV, submillimeter absorber layers are required, which cannot be realized using the microfabrication process. This paper first briefly introduces a set of TES X-ray detectors and their auxiliary systems, and then focuses on the introduction of the TES gamma-ray detector with an absorber based on a submillimeter lead-tin alloy sphere. The detector achieved a quantum efficiency above 70% near 100 keV and an energy resolution of approximately 161.5 eV at 59.5 keV.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Development of an Area Image Sensor Pixel for an X-Ray Detector
    Suponnikov D.A.
    Putilin A.N.
    Tatarinova E.A.
    Zhgunev Z.G.
    Dabagov A.R.
    Russian Microelectronics, 2019, 48 (07): : 470 - 476
  • [42] Prototype Development of Silicon Array Sensor for X-Ray Detector
    Kim, H. O.
    Kah, D. H.
    Hyun, H. J.
    Kim, Y. I.
    Son, D. H.
    Park, H.
    Kim, H. J.
    Kang, H. D.
    Lee, S. H.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 291 - 292
  • [43] Small X-Ray Telescope Based on Lobster Eye X-Ray Optics and Pixel Detector
    Tichy, Vladimir
    Hromcik, Martin
    Hudec, Rene
    Inneman, Adolf
    Jakubek, Jan
    Marsik, Jiri
    Pina, Ladislav
    Semencova, Veronika
    Sveda, Libor
    EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE, 2009, 7360
  • [44] A multielectrode X-ray detector
    Barykov, IA
    Gott, YV
    Stepanenko, MM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2006, 49 (02) : 270 - 273
  • [45] A multielectrode X-ray detector
    I. A. Barykov
    Yu. V. Gott
    M. M. Stepanenko
    Instruments and Experimental Techniques, 2006, 49 : 270 - 273
  • [46] THE PHOTOMULTIPLIER X-RAY DETECTOR
    MARSHALL, FH
    COLTMAN, JW
    HUNTER, LP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1947, 18 (07): : 504 - 513
  • [47] THE PHOTOMULTIPLIER X-RAY DETECTOR
    MARSHALL, FH
    HUNTER, LP
    PHYSICAL REVIEW, 1946, 69 (1-2): : 48 - 48
  • [48] A spectrozonal X-ray detector
    Lelyukhin A.S.
    Kornev E.A.
    Biomedical Engineering, 2004, 38 (4) : 176 - 179
  • [49] An X-ray transition radiation beam profile detector for the LCLS
    Monteiro, S
    Pellegrini, C
    NONLINEAR AND COLLECTIVE PHENOMENA IN BEAM PHYSICS 1998 WORKSHOP, 1999, 468 : 237 - 243