Transition edge sensor-based detector: from X-ray to γ-ray

被引:0
|
作者
Zhang, Shuo [1 ]
Xia, Jing-Kai [1 ]
Sun, Tao [2 ]
Wu, Wen-Tao [2 ]
Wu, Bing-Jun [2 ]
Wang, Yong-Liang [2 ]
Cantor, Robin [3 ]
Han, Ke [4 ,5 ]
Zhou, Xiao-Peng [6 ]
Liu, Hao-Ran [7 ]
Fan, Fu-You [7 ]
Guo, Si-Ming [7 ]
Liang, Jun-Cheng [7 ]
Li, De-Hong [7 ]
Song, Yan-Ru [1 ]
Ju, Xu-Dong [1 ]
Fu, Qiang [1 ]
Liu, Zhi [1 ]
机构
[1] ShanghaiTech Univ, Ctr Transformat Sci, Shanghai 201210, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, Shanghai 200050, Peoples R China
[3] STAR Cryoelect, 25-A Bisbee Court, Santa Fe, NM 87508 USA
[4] Shanghai Jiao Tong Univ, Shanghai Lab Particle Phys & Cosmol, INPAC, Shanghai 200240, Peoples R China
[5] Shanghai Jiao Tong Univ, Dept Phys & Astron, Shanghai 200240, Peoples R China
[6] Beihang Univ, Sch Phys, Beijing 100191, Peoples R China
[7] Natl Inst Metrol, Div Ionizing Radiat, NIM, 18 Bei San Huan Dong Lu, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
Synchrotron radiation instrumentation; X-ray spectrometers; Cryogenic detectors; Transition edge sensor; SPECTROSCOPY; SPECTROMETER; CALORIMETER;
D O I
10.1007/s41365-022-01071-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A transition edge sensor (TES) is extremely sensitive to changes in temperature, and combined with a high-Z metal of a certain thickness, it can realize high-energy resolution measurements of particles such as X-rays. X-rays with energies below 10 keV have a weak penetrating ability, hence, only gold or bismuth of a few micrometers in thickness can guarantee a quantum efficiency higher than 70%. Therefore, the entire structure of the TES X-ray detector in this energy range can be realized using a microfabrication process. However, for X-rays or gamma-rays from 10 keV to 200 keV, submillimeter absorber layers are required, which cannot be realized using the microfabrication process. This paper first briefly introduces a set of TES X-ray detectors and their auxiliary systems, and then focuses on the introduction of the TES gamma-ray detector with an absorber based on a submillimeter lead-tin alloy sphere. The detector achieved a quantum efficiency above 70% near 100 keV and an energy resolution of approximately 161.5 eV at 59.5 keV.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] X-ray detector based on GaN
    Duboz, J. Y.
    Frayssinet, E.
    Chenot, Sebastien
    Reverchon, J. L.
    Idir, M.
    GALLIUM NITRIDE MATERIALS AND DEVICES VIII, 2013, 8625
  • [22] Performance of the SRON Ti/Au Transition Edge Sensor X-ray Calorimeters
    de Wit, Martin
    Gottardi, Luciano
    Nagayoshi, Kenichiro
    Akamatsu, Hiroki
    Bruijn, Marcel P.
    Ridder, Marcel L.
    Taralli, Emanuele
    Vaccaro, Davide
    Gao, Jian-Rong
    den Herder, Jan-Willem A.
    SPACE TELESCOPES AND INSTRUMENTATION 2022: ULTRAVIOLET TO GAMMA RAY, 2022, 12181
  • [23] X-RAY PHOTOEMISSION FROM LITHIUM - EXPLANATION OF ITS X-RAY EDGE
    BAER, Y
    CITRIN, PH
    WERTHEIM, GK
    PHYSICAL REVIEW LETTERS, 1976, 37 (01) : 49 - 52
  • [24] X-ray photon counting detector for x-ray pulsar-based navigation
    Hu Hui-Jun
    Zhao Bao-Sheng
    Sheng Li-Zhi
    Yan Qiu-Rong
    Chen Bao-Mei
    Wang Peng
    ACTA PHYSICA SINICA, 2012, 61 (01)
  • [25] Transition edge X-ray sensors for industrial applications
    Tanaka, K
    Morooka, T
    Fujimoto, R
    Ishisaki, Y
    Takei, Y
    Morita, U
    Iyomoto, N
    Oshima, T
    Nakayama, S
    Yamasaki, N
    Koyanagi, M
    Mitsuda, K
    Ohashi, T
    Chinone, K
    PHYSICA B-CONDENSED MATTER, 2003, 329 : 1619 - 1620
  • [26] Transition edge sensors for imaging x-ray spectrometers
    Hoevers, HFC
    ADVANCES IN SOLID STATE PHYSICS 42, 2002, 42 : 483 - 494
  • [27] Microstructure Analysis of Bismuth Absorbers for Transition-Edge Sensor X-ray Microcalorimeters
    Daikang Yan
    Ralu Divan
    Lisa M. Gades
    Peter Kenesei
    Timothy J. Madden
    Antonino Miceli
    Jun-Sang Park
    Umeshkumar M. Patel
    Orlando Quaranta
    Hemant Sharma
    Douglas A. Bennett
    William B. Doriese
    Joseph W. Fowler
    Johnathon D. Gard
    James P. Hays-Wehle
    Kelsey M. Morgan
    Daniel R. Schmidt
    Daniel S. Swetz
    Joel N. Ullom
    Journal of Low Temperature Physics, 2018, 193 : 225 - 230
  • [28] Development of Position-Sensitive Transition-Edge Sensor X-Ray Detectors
    Smith, Stephen James
    Bandler, Simon R.
    Brekosky, Regis P.
    Brown, Ari-David
    Chervenak, Jay A.
    Eckart, Megan E.
    Figueroa-Feliciano, Encetali
    Finkbeiner, Fred M.
    Kelley, Richard L.
    Kilbourne, Caroline A.
    Porter, Frederick Scott
    Sadleir, John E.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 451 - 455
  • [29] High-speed superconducting x-ray calorimeter using a transition edge sensor
    Morooka, T
    Tanaka, K
    Nagata, A
    Nakayama, S
    Chinone, K
    Futamoto, K
    Fujimoto, R
    Mitsuda, K
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2002, 15 (01): : 133 - 135
  • [30] X-Ray Response of a Transition Edge Sensor Microcalorimeter With a Mushroom-Shaped Absorber
    Ezaki, S.
    Maehata, K.
    Iyomoto, N.
    Maeda, M.
    Hara, T.
    Mitsuda, K.
    Tanaka, K.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (03) : 1 - 4