THE MEAN MACHINE; ACCURATE NON-INVASIVE BLOOD PRESSURE MEASUREMENT IN THE CRITICALLY ILL PATIENT

被引:13
|
作者
Muecke, Sandy [1 ]
Bersten, Andrew [1 ]
Plummer, John [2 ]
机构
[1] Flinders Univ S Australia, Dept Crit Care Med, Adelaide, SA 5042, Australia
[2] Flinders Med Ctr, Pain Management Unit, Adelaide, SA 5042, Australia
关键词
critical illness; blood pressure monitoring; validation; non-invasive; indirect; ASCENDING AORTIC PRESSURE; ARTERY PRESSURE; OSCILLOMETRIC METHOD; MEASURING DEVICES; SYSTEM; RELIABILITY; VALIDATION; AGREEMENT; WAVES; HYPERTENSION;
D O I
10.1007/s10877-009-9195-7
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. Accurate indirect prehospital blood pressure measurement in the critically ill patient remains an important challenge to both patient management and prehospital research. Ambulatory blood pressure measuring devices have not been trialled for prehospital use in critically ill patients. Prior to prehospital validation where conditions are suboptimal, we aimed to test under favourable conditions in the Intensive Care Unit, a selection of ambulatory devices that may be suitable for use in the field. Methods. Systolic, diastolic and mean pressures of three ambulatory devices were compared to the average of 1 min of independently recorded, high fidelity intra-arterial reference pressures. Eighteen critically ill patients were recruited. Device performance was required to fulfil the Association for the Advancement of Medical Instrumentation (AAMI) protocol. Additionally, agreement between measurement methods was examined using Bland-Altman plots. Two-level linear mixed model analyses were undertaken. Results. For each device, 150 paired measurements (arterial reference and device) were analysed. According to the AAMI protocol, no device measured systolic pressures accurately. One device measured diastolic pressures accurately. Integrated mean pressures were accurately measured by all devices. Overall, SunTech Medical's Oscar 2 performed best with mean pressure error not exceeding 17 mmHg. For this device, Bland-Altman plots showed uniform agreement across a wide range of mean pressures. Two-level linear mixed effects analyses showed that Oscar 2 mean error reduced during vasopressor use by (-) 3.9 mmHg (95% CI -5.9, -1.9; P < 0.001), and clinically, performance was little affected during mechanical ventilation. For the Oscar 2, there was up to (-) 7.0 mmHg (95% CI -10.3, -3.5; P < 0.001) l ess mean error during hypotension compared to normotension. Conclusions. In the Intensive Care Unit, the performance of one device, the Oscar 2, surpassed the others and fulfilled the AAMI protocol criteria for mean pressure measurement. This device is suitable for prehospital validation.
引用
收藏
页码:283 / 297
页数:15
相关论文
共 50 条
  • [41] NON-INVASIVE PULSE OXIMETRY FOR MEASUREMENT OF OXYGEN-SATURATION IN CRITICALLY ILL PATIENTS
    SPISS, CK
    MAURITZ, W
    ZADROBILEK, E
    DRAXLER, V
    ANAESTHESIST, 1985, 34 (08): : 405 - 408
  • [42] Diagnosis of fungal infections: Role of new non-invasive tools in the critically ill patient
    Marchetti, Oscar
    INFLAMMATION RESEARCH, 2007, 56 : S249 - S249
  • [43] Feasibility of continuous non-invasive blood pressure measurement in infants
    Schraa, O
    Andriessen, P
    Smit, B
    van den Bosch-Ruis, W
    van Koppen, M
    Settels, JJ
    JOURNAL OF HYPERTENSION, 2004, 22 : S280 - S280
  • [44] Concept for a Permanent, Non-Invasive Blood Pressure Measurement in the Ear
    Zeilfelder, Jennifer
    Diehl, Matthias
    Pylatiuk, Christian
    Stork, Wilhelm
    2019 IEEE EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL & HEALTH INFORMATICS (BHI), 2019,
  • [45] The System of Indicators of the Continuous Non-Invasive Blood Pressure Measurement
    Timokhov, Gennady, V
    Semenova, Evgeniia A.
    Pivovarov, Vladimir V.
    PROCEEDINGS OF THE 2021 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (ELCONRUS), 2021, : 1860 - 1864
  • [46] Suitability of the forearm for non-invasive blood pressure measurement in children
    Greaney, David
    Nakhjavani, Solmaz
    Desmond, Fiona
    Tormey, Mark
    Dawkins, Ian
    O'Hare, Brendan
    PEDIATRIC ANESTHESIA, 2017, 27 (11) : 1125 - 1130
  • [47] Instantaneous non-invasive measurement of blood pressure in the newborn.
    Drouin, E
    Goumay, V
    Calamel, J
    Mouzard, A
    Roze, JC
    PEDIATRIC RESEARCH, 1996, 39 (04) : 1221 - 1221
  • [48] Assessing the strengths and limitations of non-invasive blood pressure measurement
    Hanover, Jeffrey
    JOURNAL OF CLINICAL HYPERTENSION, 2023, 25 (10): : 965 - 966
  • [49] SUITABILITY OF THE FOREARM FOR AUTOMATED NON-INVASIVE BLOOD PRESSURE MEASUREMENT
    Rajan, N.
    Rao, S. L.
    ANESTHESIA AND ANALGESIA, 2014, 118 : S22 - S22
  • [50] Non-invasive blood pressure measurement in animals: Part 1-Techniques for measurement and validation of non-invasive devices
    Skelding, Alicia
    Valverde, Alexander
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2020, 61 (04): : 368 - 374