THE MEAN MACHINE; ACCURATE NON-INVASIVE BLOOD PRESSURE MEASUREMENT IN THE CRITICALLY ILL PATIENT

被引:13
|
作者
Muecke, Sandy [1 ]
Bersten, Andrew [1 ]
Plummer, John [2 ]
机构
[1] Flinders Univ S Australia, Dept Crit Care Med, Adelaide, SA 5042, Australia
[2] Flinders Med Ctr, Pain Management Unit, Adelaide, SA 5042, Australia
关键词
critical illness; blood pressure monitoring; validation; non-invasive; indirect; ASCENDING AORTIC PRESSURE; ARTERY PRESSURE; OSCILLOMETRIC METHOD; MEASURING DEVICES; SYSTEM; RELIABILITY; VALIDATION; AGREEMENT; WAVES; HYPERTENSION;
D O I
10.1007/s10877-009-9195-7
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. Accurate indirect prehospital blood pressure measurement in the critically ill patient remains an important challenge to both patient management and prehospital research. Ambulatory blood pressure measuring devices have not been trialled for prehospital use in critically ill patients. Prior to prehospital validation where conditions are suboptimal, we aimed to test under favourable conditions in the Intensive Care Unit, a selection of ambulatory devices that may be suitable for use in the field. Methods. Systolic, diastolic and mean pressures of three ambulatory devices were compared to the average of 1 min of independently recorded, high fidelity intra-arterial reference pressures. Eighteen critically ill patients were recruited. Device performance was required to fulfil the Association for the Advancement of Medical Instrumentation (AAMI) protocol. Additionally, agreement between measurement methods was examined using Bland-Altman plots. Two-level linear mixed model analyses were undertaken. Results. For each device, 150 paired measurements (arterial reference and device) were analysed. According to the AAMI protocol, no device measured systolic pressures accurately. One device measured diastolic pressures accurately. Integrated mean pressures were accurately measured by all devices. Overall, SunTech Medical's Oscar 2 performed best with mean pressure error not exceeding 17 mmHg. For this device, Bland-Altman plots showed uniform agreement across a wide range of mean pressures. Two-level linear mixed effects analyses showed that Oscar 2 mean error reduced during vasopressor use by (-) 3.9 mmHg (95% CI -5.9, -1.9; P < 0.001), and clinically, performance was little affected during mechanical ventilation. For the Oscar 2, there was up to (-) 7.0 mmHg (95% CI -10.3, -3.5; P < 0.001) l ess mean error during hypotension compared to normotension. Conclusions. In the Intensive Care Unit, the performance of one device, the Oscar 2, surpassed the others and fulfilled the AAMI protocol criteria for mean pressure measurement. This device is suitable for prehospital validation.
引用
收藏
页码:283 / 297
页数:15
相关论文
共 50 条
  • [1] The Mean Machine; Accurate Non-invasive Blood Pressure Measurement in the Critically Ill Patient
    Sandy Muecke
    Andrew Bersten
    John Plummer
    Journal of Clinical Monitoring and Computing, 2009, 23 : 283 - 297
  • [2] THE MEAN PREHOSPITAL MACHINE; ACCURATE PREHOSPITAL NON-INVASIVE BLOOD PRESSURE MEASUREMENT IN THE CRITICALLY ILL PATIENT
    Muecke, Sandy
    Bersten, Andrew
    Plummer, John
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2010, 24 (03) : 191 - 202
  • [3] The Mean Prehospital Machine; accurate prehospital non-invasive blood pressure measurement in the critically ill patient
    Sandy Muecke
    Andrew Bersten
    John Plummer
    Journal of Clinical Monitoring and Computing, 2010, 24 : 191 - 202
  • [4] Continuous non-invasive blood pressure measurement for the critically ill patient- is it on its way yet?
    Martin, K.
    Gertler, R.
    MINERVA ANESTESIOLOGICA, 2013, 79 (03) : 221 - 222
  • [5] Feasibility study of continuous non-invasive blood pressure measurement in critically ill children
    C Hofhuizen
    J Lemson
    L van de Sant
    O Schraa
    J Settels
    J van der Hoeven
    Critical Care, 10 (Suppl 1):
  • [6] Correlation Between Blood Pressure Measurement by Non-invasive and Invasive Methods in Critically-ill Children
    Krishna, B. Vamshi
    Das, Suman
    Sen, Sandip
    INDIAN PEDIATRICS, 2018, 55 (04) : 297 - 300
  • [7] Correlation Between Blood Pressure Measurement by Non-invasive and Invasive Methods in Critically-ill Children
    B. Vamshi Krishna
    Suman Das
    Sandip Sen
    Indian Pediatrics, 2018, 55 : 297 - 300
  • [8] The Reliability Of Invasive And Non-Invasive Blood Pressure Measurements In Critically Ill Children
    Joffe, R.
    Guerra, G. Garcia
    Duff, J.
    Pugh, J.
    Joffe, A. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [9] Arterial blood pressure monitoring in overweight critically ill patients: Invasive or non-invasive?
    Bander, JJ
    Guzman, JA
    Araghi, A
    CHEST, 2004, 126 (04) : 746S - 747S
  • [10] Sensor fusion for the accurate non-invasive measurement of blood pressure
    Nagy P.
    Jobbágy Á.
    Measurement: Sensors, 2022, 24