A Novel Admittometric Sensor for Determination of Theophylline using FFT Coulometric Admittance Voltammetry and Flow Injection Analysis

被引:2
|
作者
Norouzi, Parviz [1 ,2 ]
Shahabi, Shirin [1 ]
Aghazadeh, Mustafa [3 ]
Larijani, Bagher [4 ]
Ghaheri, Nazanin [1 ]
机构
[1] Univ Tehran, Sch Chem, Coll Sci, Ctr Excellence Electrochem, Tehran, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Mol Cellular Sci Inst, Biosensor Res Ctr, Tehran, Iran
[3] Nucl Sci & Technol Res Inst, Mat & Nucl Res Sch, POB 14395-834, Tehran, Iran
[4] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Endocrinol & Metab Mol Cellular Sci Inst, Tehran, Iran
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2017年 / 12卷 / 11期
关键词
FFT Coulometric Admittance Voltammetry; Theophylline; Ionic liquid; Gold nanoparticles; MWCNT; CARBON-PASTE ELECTRODE; SUPERPARAMAGNETIC FE3O4 NANOPARTICLES; CONTINUOUS CYCLIC VOLTAMMETRY; ELECTROCHEMICAL SENSOR; GRAPHENE; ACETAMINOPHEN; DEPOSITION; OXIDE; NANOSTRUCTURE; FORMULATION;
D O I
10.20964/2017.11.90
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A new electrochemical analysis was established for the determination of Theophylline using FFT Coulometric Admittance Voltammetry (FFTCAV) technique and a new nanocomposite electrode, which was placed in a flow-injection system. The electrode was constructed by deposition of gold nanoparticles on mixture of multiwall carbon nanotube and chitosan casted on a carbon paste electrode containing SiC NPs and ionic liquid. The analyte response was calculated to obtain the charge changes, which was integration of the admittance in selected potential range, where the background admittance was subtracted. The electrode surface characterization was studied by electrochemical impedance spectroscopy and scanning electron microscopy techniques. As result, application of the new nanocomposite catalyzed electron transfer and causes a significant enhancement in the analyte response. It was found that the response enhanced proportionally with concentrations of Theophylline in a range from 2 to 100 nM, with a detection limit of 0.39 nM.
引用
收藏
页码:10057 / 10070
页数:14
相关论文
共 50 条
  • [31] Determination of trehalose by flow injection analysis using immobilized trehalase
    Duttingdorf, HDMZ
    Bachmann, B
    Buchholz, M
    Leuchtenberger, W
    ANALYTICAL BIOCHEMISTRY, 1997, 253 (01) : 8 - 12
  • [32] ON LINE DETERMINATION OF PERPHENAZINE USING FLOW-INJECTION ANALYSIS
    SULTAN, SM
    ABDENNABI, AM
    MICROCHEMICAL JOURNAL, 1993, 48 (03) : 343 - 348
  • [33] Determination of boron by flow injection analysis using a conductivity detector
    Kumar, SD
    Maiti, B
    Mathur, PK
    ANALYTICAL CHEMISTRY, 1999, 71 (13) : 2551 - 2553
  • [34] Extraction spectrophotometric determination of lidocaine using flow injection analysis
    Nemcová, I
    Rychlovsky, P
    Tománková, V
    Zivanovic, L
    ANALYTICAL LETTERS, 2001, 34 (14) : 2457 - 2464
  • [35] Determination of total phosphorus in waters using flow injection analysis
    Zhang, JF
    Niu, XJ
    Ma, HR
    Wang, XR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (07) : 839 - 842
  • [36] Automated determination of antibody oxidation using flow injection analysis
    Hage, D.S., 1600, Academic Press Inc. (219):
  • [37] Potentiometric Determination of Sibutramine Using Batch and Flow Injection Analysis
    El Gohary, Nesrine A.
    El Nashar, Rasha M.
    Aboul-Enien, Hassan Y.
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 241 - 257
  • [38] Ultrasensitive determination of amoxicillin using chemiluminescence with flow injection analysis
    Xie, XF
    Song, ZH
    SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2006, 20 (01): : 37 - 43
  • [39] Multicomponent determination of drugs using flow-injection analysis
    Hlabangana, Leah
    Hernandez-Cassou, Santiago
    Saurina, Javier
    CURRENT PHARMACEUTICAL ANALYSIS, 2006, 2 (02) : 127 - 140
  • [40] TURBIDIMETRIC DETERMINATION OF CHLORHEXIDINE USING FLOW-INJECTION ANALYSIS
    CALATAYUD, JM
    FALCO, PC
    SAMPEDRO, AS
    ANALYST, 1987, 112 (01) : 87 - 90