A Novel Admittometric Sensor for Determination of Theophylline using FFT Coulometric Admittance Voltammetry and Flow Injection Analysis

被引:2
|
作者
Norouzi, Parviz [1 ,2 ]
Shahabi, Shirin [1 ]
Aghazadeh, Mustafa [3 ]
Larijani, Bagher [4 ]
Ghaheri, Nazanin [1 ]
机构
[1] Univ Tehran, Sch Chem, Coll Sci, Ctr Excellence Electrochem, Tehran, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Mol Cellular Sci Inst, Biosensor Res Ctr, Tehran, Iran
[3] Nucl Sci & Technol Res Inst, Mat & Nucl Res Sch, POB 14395-834, Tehran, Iran
[4] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Endocrinol & Metab Mol Cellular Sci Inst, Tehran, Iran
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2017年 / 12卷 / 11期
关键词
FFT Coulometric Admittance Voltammetry; Theophylline; Ionic liquid; Gold nanoparticles; MWCNT; CARBON-PASTE ELECTRODE; SUPERPARAMAGNETIC FE3O4 NANOPARTICLES; CONTINUOUS CYCLIC VOLTAMMETRY; ELECTROCHEMICAL SENSOR; GRAPHENE; ACETAMINOPHEN; DEPOSITION; OXIDE; NANOSTRUCTURE; FORMULATION;
D O I
10.20964/2017.11.90
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A new electrochemical analysis was established for the determination of Theophylline using FFT Coulometric Admittance Voltammetry (FFTCAV) technique and a new nanocomposite electrode, which was placed in a flow-injection system. The electrode was constructed by deposition of gold nanoparticles on mixture of multiwall carbon nanotube and chitosan casted on a carbon paste electrode containing SiC NPs and ionic liquid. The analyte response was calculated to obtain the charge changes, which was integration of the admittance in selected potential range, where the background admittance was subtracted. The electrode surface characterization was studied by electrochemical impedance spectroscopy and scanning electron microscopy techniques. As result, application of the new nanocomposite catalyzed electron transfer and causes a significant enhancement in the analyte response. It was found that the response enhanced proportionally with concentrations of Theophylline in a range from 2 to 100 nM, with a detection limit of 0.39 nM.
引用
收藏
页码:10057 / 10070
页数:14
相关论文
共 50 条
  • [21] Determination of Thymol Using Flow Injection Analysis on New Coulometric Detector with Renewable Working Material Based on Glassy Carbon Microparticles
    Mika, Jan
    Barek, Jiri
    Zima, Jiri
    Dejmkova, Hana
    XXXIII MODERNI ELEKTROCHEMICKE METODY, 2013, : 110 - 113
  • [22] Flow Injection Glutamate Biosensor Based on Carbon Nanotubes and Pt-Nanoparticles Using FFT Continuous Cyclic Voltammetry
    Norouzi, P.
    Faridbod, F.
    Rashedi, H.
    Ganjali, M. R.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (12): : 1713 - 1725
  • [23] A novel biamperometric biosensor for urinary oxalate determination using flow-injection analysis
    Milardovic, Stjepan
    Kerekovic, Irena
    Nodilo, Marijana
    TALANTA, 2008, 77 (01) : 222 - 228
  • [24] Determination of bromhexine at a glassy carbon paste electrode using differential pulse voltammetry and flow injection analysis with amperometric detection
    Mika, Jan
    Moreira, Josino C.
    Nemeckova, Andrea
    Zima, Jiri
    Barek, Jiri
    Dejmkova, Hana
    MONATSHEFTE FUR CHEMIE, 2015, 146 (08): : 1211 - 1215
  • [25] Determination of bromhexine at a glassy carbon paste electrode using differential pulse voltammetry and flow injection analysis with amperometric detection
    Jan Mika
    Josino C. Moreira
    Andrea Nemeckova
    Jiri Zima
    Jiri Barek
    Hana Dejmkova
    Monatshefte für Chemie - Chemical Monthly, 2015, 146 : 1211 - 1215
  • [26] ONLINE BROMIMETRIC DETERMINATION OF PHENOL, ANILINE, ASPIRIN AND ISONIAZID USING FLOW-INJECTION VOLTAMMETRY
    FOGG, AG
    ALI, A
    ABDALLA, MA
    ANALYST, 1983, 108 (1288) : 840 - 846
  • [27] Spectrophotometric determination of sulphide using flow injection analysis
    Yaqoob, M
    Nabi, A
    Wahab, A
    Bano, A
    Shah, SH
    Achakzai, AKK
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 1998, 20 (03): : 214 - 216
  • [28] ENZYMATIC SENSOR COUPLED TO A FLOW-INJECTION ANALYSIS SYSTEM FOR THE DETERMINATION OF SALICYLATE
    NEUMAYR, M
    SONTAG, G
    PITTNER, F
    ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 26 - 31
  • [29] Rapid determination of bisacodyl in flow injection system combination by a novel sensitive adsorptive square-wave voltammetry
    Daneshgar, Parandis
    Norouzi, Parviz
    Ganjali, Mohammad Reza
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 136 (01): : 66 - 72
  • [30] Flow Injection Phosphate Biosensor Based on PyOx-MWCNTs Film on a Glassy Carbon Electrode Using FFT Continuous Cyclic Voltammetry
    Norouzi, P.
    Pirali-Hamedani, M.
    Faridbod, F.
    Ganjali, M. R.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (09): : 1225 - 1235