Comparison of Moderate Hypofractionated Volumetric-Modulated Arc Therapy Plans With and Without Flattening Filter for Localized Prostate Cancer

被引:3
|
作者
Takakusagi, Yosuke [1 ]
Usui, Keisuke [2 ]
Mizoguchi, Nobutaka [1 ]
Nagatsuka, Jun [3 ]
Hikage, Takeshi [3 ]
Kodama, Yasuhiko [3 ]
Ezura, Takatomo [4 ]
Kusunoki, Terufumi [4 ]
Oizumi, Yukio [5 ]
机构
[1] Kanagawa Canc Ctr, Dept Radiat Oncol, Yokohama, Kanagawa, Japan
[2] Juntendo Univ, Dept Radiat Oncol, Tokyo, Japan
[3] Yokosuka Gen Hosp Uwamachi, Dept Radiol, Yokosuka, Kanagawa, Japan
[4] Kanagawa Canc Ctr, Sect Med Phys & Engn, Yokohama, Kanagawa, Japan
[5] Yokosuka Gen Hosp Uwamachi, Dept Radiat Oncol, Yokosuka, Kanagawa, Japan
关键词
comparison; moderate hypofractionation; prostate cancer; vmat; flattening filter-free; RADIATION-THERAPY; ALPHA/BETA RATIO; RADIOTHERAPY; BEAMS; VMAT; GY; FLUENCE; IMRT;
D O I
10.7759/cureus.18034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Aim The aim of this study was to compare volumetric-modulated arc therapy (VMAT) radiation plans between conventional VMAT with flattening filter (cFF-VMAT) and flattening filter-free VMAT (FFF-VMAT) for localized prostate cancer. Materials and methods Ten patients with localized prostate cancer who underwent cFF-VMAT at Yokosuka General Hospital Uwamachi, Yokosuka, Japan, from July 2020 to October 2020 were enrolled. Dose-volume histogram (DVH) parameters of the target volume, normal organs, monitor units (MU), and beam-on time (BOT) were compared between cFF-VMAT and FFF-VMAT plans. Results No significant difference was observed for DVH parameters for the target volume. No significant difference was observed in all parameters for the bladder and rectum between the cFF-VMAT and FFF-VMAT groups. The mean values of MU were 686 +/- 52 and 784 +/- 80 in cFF-VMAT and FFF-VMAT, respectively (p < 0.001). The mean BOT was 97.0 +/- 6.6 s and 72.9 +/- 1.4 s for cFF-VMAT and FFF-VMAT, respectively (p < 0.001). Conclusion DVH parameters of the target volume and normal organs were not significantly different between the cFFVMAT and FFF-VMAT plans. In FFF-VMAT, MU was significantly higher, and the BOT was significantly shorter than those in cFF-VMAT.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Moderate hypofractionated radiotherapy with volumetric modulated arc therapy and simultaneous integrated boost for pelvic irradiation in prostate cancer
    Franzese, C.
    Fogliata, A.
    D'Agostino, G. R.
    Di Brina, L.
    Comito, T.
    Navarria, P.
    Cozzi, L.
    Scorsetti, M.
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2017, 143 (07) : 1301 - 1309
  • [22] Dosimetric comparison of RapidPlan and manually optimised volumetric modulated arc therapy plans in prostate cancer
    Chua, Loyce M. H.
    Pang, Eric P. P.
    Master, Zubin
    Sultana, Rehena
    Tuan, Jeffrey K. L.
    Bragg, Christopher M.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (03) : 257 - 264
  • [23] VOLUMETRIC MODULATED ARC THERAPY(VMAT) FOR THE TREATMENT OF LOCALIZED PROSTATE CANCER
    Shiraishi, Kenshiro
    Yamamoto, Kentaro
    Haga, Akihiro
    Sakumi, Akira
    Nomoto, Akihiro
    Nakagawa, Keiichi
    ANNALS OF ONCOLOGY, 2014, 25
  • [24] Dosimetric comparison of RapidPlan and manually optimized plans in volumetric modulated arc therapy for prostate cancer
    Kubo, Kazuki
    Monzen, Hajime
    Ishii, Kentaro
    Tamura, Mikoto
    Kawamorita, Ryu
    Sumida, Iori
    Mizuno, Hirokazu
    Nishimura, Yasumasa
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 199 - 204
  • [25] Efficiency of Flattening Filter Free Beam in Volumetric Modulated Arc Therapy for LIVER and Lung SBRT Plans
    Andavar, S.
    Roshan, V.
    Dhiman, A.
    Singh, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 2974 - 2974
  • [26] Multi-criteria optimization for planning volumetric-modulated arc therapy for prostate cancer
    Park, Jongmoo
    Park, Jaehyeon
    Oh, Sean
    Yea, Ji Woon
    Lee, Jeong Eun
    Park, Jae Won
    PLOS ONE, 2021, 16 (09):
  • [27] Physical and Radiobiological Dosimetric Comparison of Volumetric Arc Treatment Plans with or without Flattening Filter in Synchronous Bilateral Breast Cancer
    Patil, Deepali
    Zope, Mukesh
    Madhawi, Richa
    Raj, Shraddha
    Kishor, Kunal
    Devi, Seema
    Singh, Rajesh
    Singh, Devraj
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2024, 39 (04): : 411 - 422
  • [28] FLATTENING FILTER FREE BEAMS FOR HYPOFRACTIONATED RADIOTHERAPY OF LOCALIZED PROSTATE CANCER
    Lang, S.
    Hrbacek, J.
    Najafi, Y.
    Streller, T.
    Klock, S.
    Studer, G.
    Zaugg, K.
    Luetolf, U. M.
    Zwahlen, D.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S188 - S189
  • [29] A treatment planning and delivery comparison of volumetric modulated arc therapy with or without flattening filter for gliomas, brain metastases, prostate, head/neck and early stage lung cancer
    Gasic, Daniel
    Ohlhues, Lars
    Brodin, N. Patrik
    Fog, Lotte S.
    Pommer, Tobias
    Bangsgaard, Jens P.
    Rosenschold, Per Munck A. F.
    ACTA ONCOLOGICA, 2014, 53 (08) : 1005 - 1011
  • [30] Hypofractionated volumetric-modulated arc therapy for breast cancer: A propensity-score-weighted comparison of radiation-related toxicity
    Kim, Nalee
    Chang, Jee Suk
    Shah, Chirag
    Shin, Hyejung
    Keum, Ki Chang
    Suh, Chang-Ok
    Kim, Yong Bae
    INTERNATIONAL JOURNAL OF CANCER, 2021, 149 (01) : 149 - 157