A study of long term operation and reliability of heated atomic force microscope cantilevers

被引:4
|
作者
Kim, Hoe Joon [1 ]
King, William P. [1 ]
机构
[1] Univ Illinois, Dept Mech Sci & Engn, Urbana, IL 61801 USA
关键词
AFM; microcantilever; reliability; dopant diffusion; DATA-STORAGE; SILICON; DIFFUSION; PHOSPHORUS; MECHANISMS; AFM;
D O I
10.1088/0960-1317/25/6/065003
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a detailed investigation of the long term operation and reliability of heated atomic force microscope (AFM) cantilevers. The electrical and thermal operation of these heated AFM cantilevers depends upon the distribution of dopants within the silicon cantilever. Over long term operation, or for operation at very high temperatures, the cantilevers' electro-thermal properties can change due to dopant diffusion at the junction between the cantilever heater and the cantilever leg. We analyze this change in cantilever behavior at high heating temperatures, up to 1100 degrees C, and long heating times, up to 108 h. At extreme heating conditions, the cantilevers' electro-thermal properties change by as much as 24%, resulting in significant errors in cantilever calibration. The main failure mechanism of these heated AFM cantilevers is the melting of heater-leg junction at high cantilever temperatures, as high junction resistances induced the localized heating. Understanding and accounting for long term operational reliability is crucial for consistent and repeatable uses of heated cantilevers, especially for applications in material property measurements and nanomanufacturing.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] MICROFLUIDIC FABRICATION APPROACH FOR ATOMIC FORCE MICROSCOPE CANTILEVERS WITH PHOTOCURABLE RESINS
    Lee, Bora
    Yoon, Yeowon
    Lee, Jungchul
    2018 IEEE MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2018, : 1275 - 1278
  • [42] Size dependent on vibration and flexural sensitivity of atomic force microscope cantilevers
    Javidi, Reza
    Gorgani, Hamid Haghshenas
    Adeli, Mohsen Mahdavi
    JOURNAL OF COMPUTATIONAL APPLIED MECHANICS, 2019, 50 (01): : 191 - 196
  • [43] Analysis of the high-frequency response of atomic force microscope cantilevers
    Rabe, U
    Turner, J
    Arnold, W
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1998, 66 (Suppl 1): : S277 - S282
  • [44] Modular apparatus for electrostatic actuation of common atomic force microscope cantilevers
    Long, Christian J.
    Cannara, Rachel J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (07):
  • [45] Characterisation of the mechanical properties of thin film cantilevers with the atomic force microscope
    CSIRO Div of Chemicals and Polymers, Clayton
    Materials Science Forum, 1995, 189-190 : 107 - 114
  • [46] High-frequency response of atomic-force microscope cantilevers
    Turner, JA
    Hirsekorn, S
    Rabe, U
    Arnold, W
    JOURNAL OF APPLIED PHYSICS, 1997, 82 (03) : 966 - 979
  • [47] Imaging using lateral bending modes of atomic force microscope cantilevers
    Caron, A
    Rabe, U
    Reinstädtler, M
    Turner, JA
    Arnold, W
    APPLIED PHYSICS LETTERS, 2004, 85 (26) : 6398 - 6400
  • [48] Low-temperature atomic force microscope using piezoresistive cantilevers
    Thomson, RE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (08): : 3369 - 3372
  • [49] Spring constant calibration of atomic force microscope cantilevers of arbitrary shape
    Sader, John E.
    Sanelli, Julian A.
    Adamson, Brian D.
    Monty, Jason P.
    Wei, Xingzhan
    Crawford, Simon A.
    Friend, James R.
    Marusic, Ivan
    Mulvaney, Paul
    Bieske, Evan J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [50] ATOMIC-FORCE MICROSCOPE USING PIEZORESISTIVE CANTILEVERS AND COMBINED WITH A SCANNING ELECTRON-MICROSCOPE
    STAHL, U
    YUAN, CW
    DELOZANNE, AL
    TORTONESE, M
    APPLIED PHYSICS LETTERS, 1994, 65 (22) : 2878 - 2880