Carpentier-Edwards standard and supraannular porcine bioprostheses: Comparison of technology

被引:25
|
作者
Jamieson, WRE [1 ]
Burr, LH [1 ]
Janusz, MT [1 ]
Munro, AI [1 ]
Hayden, RI [1 ]
Miyagishima, RT [1 ]
Ling, H [1 ]
Fradet, GJ [1 ]
Lichtenstein, SV [1 ]
Stewart, KM [1 ]
机构
[1] Univ British Columbia, Div Cardiovasc Surg, Vancouver, BC V5Z 1M9, Canada
来源
ANNALS OF THORACIC SURGERY | 1999年 / 67卷 / 01期
关键词
D O I
10.1016/S0003-4975(98)01056-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Performance with regard to structural valve deterioration (SVD) with the Carpentier-Edwards standard (CE-S) and supraannular (CE-SAV) (Baxter Healthcare Corp, Irvine, CA) porcine bioprostheses was evaluated to determine whether progress in reduction of structural failure has been achieved with technological changes. Methods. The CE-S was implanted during 567 aortic valve replacement (AVR) and 486 mitral valve replacement (MVR) procedures, and the CE-SAV was implanted during 1,670 AVR and 1,096 MVR procedures. The failure mode of early stent dehiscence with the CE-SAV prosthesis, thought to be controlled by manufacturing changes in 1986 and 1987, supported comparison of the CE-SAV with censored cases of stent dehiscence. Stent dehiscence accounted for only 1.2% (1 of 81) and 14.1% (29 of 205) of AVR and MVR CE-SAV failures, respectively. Results. The only difference for AVR for freedom from SVD occurred in the 21- to 40-year age group at 15 years and was 68% for the CE-SAV and 31% for the CE-S (p < 0.05). In the 61- to 70-year age group, freedom from SVD at 15 years was 76% for the CE-S and 84% for the CE-SAV; for the 71-year or higher age group, freedom from SVD was 89% and 95%, respectively (p = NS). For MVR freedom from SVD was different only in the 71-year or higher age group and was 90% for the CE-S and 59% for the CE-SAV (p < 0.05). Freedom from SVD was reduced but was similar (p = NS) for the other age groups. For AVR the actual freedom from SVD at 15 years for the CE-S and CE-SAV was, respectively, 79% and 72% for the 51- to 60-year age group, 86% and 91% for the 61- to 70-year age group, and 98% and 98% for the 71-year or higher age group. For MVR, these rates were, respectively, 69% and 75% for the 61- to 70-year age group and 96% and 89% for the 71-year and higher age group. Conclusions. The technologic advancements made in the second-generation CE-SAV bioprosthesis to reduce the incidence of structural failure have not uniformly been successful. The actual freedom from SVD provides evidence for implantation of porcine bioprostheses for AVR in age groups 61 to 70 years and 71 years or higher and for MVR in the age group 71 years or higher. (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:10 / 17
页数:8
相关论文
共 50 条
  • [31] Actuarial versus actual freedom from structural valve deterioration with the Carpentier-Edwards porcine bioprostheses
    Jamieson, WRE
    Burr, LH
    Miyagishima, RT
    Germann, E
    Anderson, WN
    CANADIAN JOURNAL OF CARDIOLOGY, 1999, 15 (09) : 973 - 978
  • [32] UNUSUAL COMPLICATION OF A CARPENTIER-EDWARDS PORCINE VALVE
    TOLIS, GA
    MICHALIS, A
    POULIOU, A
    IVROS, C
    BOLOS, C
    SFYRAS, N
    TEXAS HEART INSTITUTE JOURNAL, 1986, 13 (03) : 337 - 339
  • [33] Acute dysfunction of porcine bioprosthesis Carpentier-Edwards
    Tota, Antonio
    Carbone, Carmine
    Caldarola, Pasquale
    GIORNALE ITALIANO DI CARDIOLOGIA, 2010, 11 (10) : 789 - 791
  • [34] THE CARPENTIER-EDWARDS SUPRAANNULAR PORCINE BIOPROSTHESIS - A NEW GENERATION TISSUE VALVE WITH EXCELLENT INTERMEDIATE CLINICAL-PERFORMANCE
    JAMIESON, WRE
    MUNRO, AI
    MIYAGISHIMA, RT
    BURR, LH
    GEREIN, AN
    JANUSZ, MT
    TYERS, GFO
    ALLEN, P
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1988, 96 (04): : 652 - 666
  • [35] LATE RESULTS WITH CARPENTIER-EDWARDS PORCINE BIOPROSTHESIS
    AKINS, CW
    CARROLL, DL
    BUCKLEY, MJ
    DAGGETT, WM
    HILGENBERG, AD
    AUSTEN, WG
    CIRCULATION, 1990, 82 (05) : 65 - 74
  • [36] HEMODYNAMIC EVALUATION OF THE CARPENTIER-EDWARDS PORCINE XENOGRAFT
    CHAITMAN, BR
    BONAN, R
    LEPAGE, G
    TUBAU, JF
    DAVID, PR
    DYRDA, I
    GRONDIN, CM
    CIRCULATION, 1979, 60 (05) : 1170 - 1182
  • [37] CARPENTIER-EDWARDS STANDARD PORCINE BIOPROSTHESIS - CLINICAL-PERFORMANCE TO 17 YEARS
    JAMIESON, WRE
    MUNRO, AI
    MIYAGISHIMA, RT
    ALLEN, P
    BURR, LH
    TYERS, GFO
    ANNALS OF THORACIC SURGERY, 1995, 60 (04): : 999 - 1007
  • [38] THE CARPENTIER-EDWARDS STANDARD PORCINE BIOPROSTHESIS - CLINICAL-PERFORMANCE TO 15 YEARS
    JAMIESON, WRE
    HAYDEN, RI
    MIYAGISHIMA, RT
    TUTASSAURA, H
    MUNRO, AI
    GEREIN, AN
    BURR, LH
    MACNAB, J
    JANUSZ, MT
    CHAN, F
    LING, H
    TYERS, GFO
    JOURNAL OF CARDIAC SURGERY, 1991, 6 (04) : 550 - 556
  • [39] Long-Term Results of the Carpentier-Edwards Supraannular Aortic Valve Prosthesis
    Ruggieri, Vito Giovanni
    Flecher, Erwan
    Anselmi, Amedeo
    Lelong, Bernard
    Corbineau, Herve
    Verhoye, Jean-Philippe
    Langanay, Thierry
    Leguerrier, Alain
    ANNALS OF THORACIC SURGERY, 2012, 94 (04): : 1191 - 1197
  • [40] Early Doppler-echocardiography evaluation of Carpentier-Edwards Standard and Carpentier-Edwards Magna aortic prosthetic valve: comparison of hemodynamic performance
    Minardi, Giovanni
    Pulignano, Giovanni
    Del Sindaco, Donatella
    Sordi, Martina
    Pavaci, Herribert
    Pergolini, Amedeo
    Zampi, Giordano
    Orsini, Francesca Moschella
    Gaudio, Carlo
    Musumeci, Francesco
    CARDIOVASCULAR ULTRASOUND, 2011, 9