Biomechanical Comparison of Fixation With a Single Screw Versus Two Kirschner Wires in Distal Chevron Osteotomies of the First Metatarsal: A Cadaver Study

被引:16
|
作者
Trost, Matthias [1 ]
Bredow, Jan [2 ]
Boese, Christoph Kolja [3 ]
Loweg, Lennard
Schulte, Tobias Ludger [1 ]
Scaal, Martin [4 ]
Eysel, Peer [5 ,6 ]
Oppermann, Johannes [6 ]
机构
[1] Univ Bochum, St Josef Hosp, Dept Orthopaed & Traumatol, Gudrunstr 56, D-44791 Bochum, Germany
[2] Schon Klin, Dept Spinal Surg, Dusseldorf, Germany
[3] Cologne Univ Hosp, Dept Orthopaed & Traumatol, Cologne, Germany
[4] Univ Cologne, Inst Anat 2, Cologne, Germany
[5] Cologne Univ Hosp, Dept Orthopaed & Traumatol, Cologne, Germany
[6] Univ Cologne, Cologne Ctr Musculoskeletal Biomech, Cologne, Germany
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2018年 / 57卷 / 01期
关键词
cantilever; foot; hallux valgus; load; osteosynthesis; RANDOMIZED CONTROLLED-TRIAL; SEVERE HALLUX-VALGUS; SOFT-TISSUE RELEASE; SHAFT OSTEOTOMIES; ANKLE ARTHRODESIS; STABILITY;
D O I
10.1053/j.jfas.2017.08.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Distal chevron osteotomy is a common procedure for surgical correction of hallux valgus. Osteosynthesis with 1 screw or 2 Kirschner wires has been commonly used. We compared the stability of the 2 techniques in distal chevron osteotomy. Sixteen first metatarsals from fresh-frozen human cadaver feet (9 different cadaveric specimens) were used. A standardized distal chevron osteotomy was performed. One first metatarsal from each pair was assigned to group 1 (3.5-mm cortical screw; n = 8) and one to group 2 (two 1.6-mm Kirschner wires; n = 8). Using a materials testing machine, the head of the first metatarsals was loaded in 2 different configurations (cantilever and physiologic) in succession. In the cantilever configuration, the relative stiffness of the osteosynthesis compared with intact bone was 59% +/- 27% in group 1 and 68% +/- 18% in group 2 (p = .50). In the physiologic configuration, it was 38% +/- 25% in group 1 and 35% +/- 7% in group 2 (p = .75). The failure strength in the cantilever configuration was 187 +/- 105 N in group 1 and 259 +/- 71 N in group 2 (p = .21). No statistically significant differences were found in stability between the 2 techniques. The use of 1 screw or 2 Kirschner wires had no significant differences in their biomechanical loading capacity for osteosynthesis in distal chevron osteotomies for treatment of hallux valgus. (C) 2017 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 50 条
  • [31] Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis injury: A biomechanical study
    Miller, RS
    Weinhold, PS
    Dahners, LE
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (01) : 39 - 42
  • [32] An In Vitro Biomechanical Comparison of Dynamic Condylar Screw Plate Combined with a Dorsal Plate and Double Plate Fixation of Distal Diaphyseal Radial Osteotomies in Adult Horses
    Janicek, John C.
    Wilson, David A.
    Carson, William L.
    Kramer, Joanne
    VETERINARY SURGERY, 2009, 38 (06) : 719 - 731
  • [33] Biomechanical Comparison between Inverted Triangle and Vertical Configurations of Three Kirschner Wires for Femoral Neck Fracture Fixation in Dogs: A Cadaveric Study
    Heo, Seonghyeon
    Lee, Haebeom
    Roh, Yoonho
    Jeong, Jaemin
    VETERINARY SCIENCES, 2023, 10 (04)
  • [34] Comparison of Lag Versus Nonlag Screw Fixation for Long Oblique Proximal Phalanx Fractures: A Biomechanical Study
    Miles, Megan R.
    Green, Tyler
    Parks, Brent G.
    Thakkar, Madhuli Y.
    Segalman, Keith A.
    Means, Kenneth R., Jr.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (05): : 476.e1 - 476.e6
  • [35] Biomechanical comparison of dynamic condylar screw and locking compression plate fixation in unstable distal femoral fractures: An in vitro study
    Singh, Ashutosh Kumar
    Rastogi, Amit
    Singh, Vakil
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (06) : 615 - 620
  • [36] Biomechanical comparison of dynamic condylar screw and locking compression plate fixation in unstable distal femoral fractures: An in vitro study
    Ashutosh Kumar Singh
    Amit Rastogi
    Vakil Singh
    Indian Journal of Orthopaedics, 2013, 47 : 615 - 620
  • [37] A clinical and biomechanical comparison of INFIX plus single versus double sacroiliac screw fixation for unstable pelvic ring injury
    Chen, Hongfen
    Ding, Chao
    Liu, Yongqiang
    Kong, Zhen
    Chang, Siling
    Huang, Feng
    Li, Heng
    Guo, Qingxiang
    Yang, Yuehua
    Zhong, Hua
    Yang, Shaozheng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [38] A clinical and biomechanical comparison of INFIX plus single versus double sacroiliac screw fixation for unstable pelvic ring injury
    Hongfen Chen
    Chao Ding
    Yongqiang Liu
    Zhen Kong
    Siling Chang
    Feng Huang
    Heng Li
    Qingxiang Guo
    Yuehua Yang
    Hua Zhong
    Shaozheng Yang
    Journal of Orthopaedic Surgery and Research, 17
  • [39] Lapidus arthrodesis in combination with arthrodesis of the first metatarsophalangeal joint-biomechanical cadaver study comparing two methods of fixation
    Kunovsky, Radek
    Kocis, Jan
    Navrat, Tomas
    Vosynek, Petr
    Pink, Tomas
    Joukal, Marek
    Cizmar, Igor
    BIOMEDICAL PAPERS-OLOMOUC, 2022, 166 (03): : 334 - 342
  • [40] Comparison of Functional and Radiological Outcomes of Olecranon Fractures Treated with Tension Band Wiring with Kirschner Wires to Transcortical Screw Fixation-A Randomised Controlled Study
    Sinha, Siddhartha
    Maharjan, Rajiv
    Khanal, Guru P.
    Pokharel, Bishnu
    Drolia, Nikhil
    Gupta, Sumit
    Kanojia, Rajesh K.
    Chaudhary, Pashupati
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2020, 15 (03) : 131 - 137