Biomechanical Comparison of Fixation With a Single Screw Versus Two Kirschner Wires in Distal Chevron Osteotomies of the First Metatarsal: A Cadaver Study

被引:16
|
作者
Trost, Matthias [1 ]
Bredow, Jan [2 ]
Boese, Christoph Kolja [3 ]
Loweg, Lennard
Schulte, Tobias Ludger [1 ]
Scaal, Martin [4 ]
Eysel, Peer [5 ,6 ]
Oppermann, Johannes [6 ]
机构
[1] Univ Bochum, St Josef Hosp, Dept Orthopaed & Traumatol, Gudrunstr 56, D-44791 Bochum, Germany
[2] Schon Klin, Dept Spinal Surg, Dusseldorf, Germany
[3] Cologne Univ Hosp, Dept Orthopaed & Traumatol, Cologne, Germany
[4] Univ Cologne, Inst Anat 2, Cologne, Germany
[5] Cologne Univ Hosp, Dept Orthopaed & Traumatol, Cologne, Germany
[6] Univ Cologne, Cologne Ctr Musculoskeletal Biomech, Cologne, Germany
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2018年 / 57卷 / 01期
关键词
cantilever; foot; hallux valgus; load; osteosynthesis; RANDOMIZED CONTROLLED-TRIAL; SEVERE HALLUX-VALGUS; SOFT-TISSUE RELEASE; SHAFT OSTEOTOMIES; ANKLE ARTHRODESIS; STABILITY;
D O I
10.1053/j.jfas.2017.08.014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Distal chevron osteotomy is a common procedure for surgical correction of hallux valgus. Osteosynthesis with 1 screw or 2 Kirschner wires has been commonly used. We compared the stability of the 2 techniques in distal chevron osteotomy. Sixteen first metatarsals from fresh-frozen human cadaver feet (9 different cadaveric specimens) were used. A standardized distal chevron osteotomy was performed. One first metatarsal from each pair was assigned to group 1 (3.5-mm cortical screw; n = 8) and one to group 2 (two 1.6-mm Kirschner wires; n = 8). Using a materials testing machine, the head of the first metatarsals was loaded in 2 different configurations (cantilever and physiologic) in succession. In the cantilever configuration, the relative stiffness of the osteosynthesis compared with intact bone was 59% +/- 27% in group 1 and 68% +/- 18% in group 2 (p = .50). In the physiologic configuration, it was 38% +/- 25% in group 1 and 35% +/- 7% in group 2 (p = .75). The failure strength in the cantilever configuration was 187 +/- 105 N in group 1 and 259 +/- 71 N in group 2 (p = .21). No statistically significant differences were found in stability between the 2 techniques. The use of 1 screw or 2 Kirschner wires had no significant differences in their biomechanical loading capacity for osteosynthesis in distal chevron osteotomies for treatment of hallux valgus. (C) 2017 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 50 条
  • [21] Comparison of two versus three-screw fixation for biplanar chevron medial malleolar osteotomy
    Aykanat, Faruk
    Egerci, Omer Faruk
    Dogruoz, Firat
    Yapar, Aliekber
    Ertan, Mehmet Baris
    Kose, Ozkan
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (05): : 2439 - 2447
  • [22] Single Versus Dual Headless Compression Screw Fixation of Scaphoid Nonunions: A Biomechanical Comparison
    Nicholson, Luke T.
    Sochol, Kristen M.
    Azad, Ali
    Alluri, Ram Kiran
    Hill, J. Ryan
    Ghiassi, Alidad
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2022, 17 (06): : 1122 - 1127
  • [23] Biomechanical comparison of pedicle screw fixation strength between traditional trajectory and the single and double endplates penetrating screw trajectories in cadaver spine
    Takeuchi, Takumi
    Takamizawa, Yuhei
    Jinnai, Kaito
    Kawano, Yosuke
    Moroi, Takehiko
    Konishi, Kazumasa
    Takahashi, Masahito
    Nagase, Miki
    Hosogane, Naobumi
    EUROPEAN SPINE JOURNAL, 2025,
  • [24] Comparison of biomechanical study of sacroiliac fixation between screw with two types of washer
    Ritthiprat, Sakuna
    5TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2012), 2012, : 80 - 80
  • [25] Comparison of biomechanical study of sacroiliac fixation between screw with two types of washer
    Ritthiprat, Sakuna
    5TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2012), 2012,
  • [26] Biomechanical comparison of transosseous re-fixation of the deep fibres of the distal radioulnar ligaments versus deep and superficial fibres: a cadaver study
    Spies, Christian K.
    Niehoff, Anja
    Unglaub, Frank
    Mueller, Lars P.
    Langer, Martin F.
    Neiss, Wolfram F.
    Oppermann, Johannes
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (02) : 315 - 321
  • [27] Biomechanical comparison of transosseous re-fixation of the deep fibres of the distal radioulnar ligaments versus deep and superficial fibres: a cadaver study
    Christian K. Spies
    Anja Niehoff
    Frank Unglaub
    Lars P. Müller
    Martin F. Langer
    Wolfram F. Neiss
    Johannes Oppermann
    International Orthopaedics, 2016, 40 : 315 - 321
  • [28] A Biomechanical Study of Calcaneal Tuberosity Avulsion Fracture: A Comparison Between Three-Screw Versus Two-Screw Fixation Strength
    Wan, Kwong-Lee
    Raghavan, Sugesh
    Chua, YeokPin
    Shanmugam, Rukmanikanthan
    Ibrahim, Mohamad Izani
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [29] Cannulated screw versus Kirschner-wire fixation for Milch II lateral condyle fractures in a paediatric sawbone model: a biomechanical comparison
    Franks, D.
    Shatrov, J.
    Symes, M.
    Little, D. G.
    Cheng, T. L.
    JOURNAL OF CHILDRENS ORTHOPAEDICS, 2018, 12 (01) : 29 - 35
  • [30] Biomechanical assessment of conventional unit rod fixation versus a unit rod pedicle screw construct -: A human cadaver study
    Erickson, MA
    Oliver, T
    Baldini, T
    Bach, J
    SPINE, 2004, 29 (12) : 1314 - 1319