Evaluation of the decellularized pulmonary valve homograft (SynerGraft™)

被引:0
|
作者
Bechtel, JFM
Müller-Steinhardt, M
Schmidtke, C
Brunswik, A
Stierle, U
Sievers, HH
机构
[1] Univ Hosp, Dept Cardiac Surg, Lubeck, Germany
[2] Med Univ Lubeck, Inst Immunol & Transfus Med, D-23538 Lubeck, Germany
来源
JOURNAL OF HEART VALVE DISEASE | 2003年 / 12卷 / 06期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Rejection is thought to contribute to the degeneration of valved homografts. A novel cryopreserved decellularized homograft valve (SynerGraft(TM); CryoLife, Inc.) offers the unique opportunity to gain new insight into the immunology of homograft implantation and its significance for valve function. Methods: Twenty-four patients (group 1; mean age 37 +/- 11 years) underwent implantation of a pulmonary SynerGraft and were examined at one and six months postoperatively; 22 patients (group 11; mean age 41 +/- 17 years) with conventional homografts served as controls. Temperature, C-reactive protein (CRP) levels and white blood cell count (WBC) were studied perioperatively. Follow up included echocardiography and anti-human leukocyte antigen (HLA) class I antibody determination. Results: Significantly lower temperatures were measured in group I (p = 0.019). CRP level and WBC each increased postoperatively, but did not differ between groups. During follow up, none of the SynerGraft patients became positive for anti-HLA antibodies, compared with 66% of controls (p = 0.011). Homograft diameter and valve orifice area were decreased significantly at one month after surgery in groups I and II (25 +/- 1 versus 18 +/- 3 mm; 25 +/- 1 versus 19 +/- 2 mm, respectively; p <0.001 both groups). Transvalvular pressure gradients significantly increased during follow up. Conclusion: Implantation of the SynerGraft pulmonary homograft appeared safe, and though evidence was found of a reduced immunologic response after SynerGraft implantation this (unexpectedly) did not translate into any hemodynamic advantage. Hence, factors other than rejection appear as the main contributions to the observed functional changes.
引用
收藏
页码:734 / 739
页数:6
相关论文
共 50 条
  • [41] THE CRYOPRESERVED HOMOGRAFT VALVE IN THE PULMONARY POSITION - MIDTERM RESULTS AND TECHNICAL CONSIDERATIONS
    LAMBERTI, JJ
    MAINWARING, RD
    BILLMAN, GF
    HOPKINS, BA
    GEORGE, L
    MATHEWSON, JW
    KIRKPATRICK, SE
    SPICER, RL
    JOURNAL OF CARDIAC SURGERY, 1991, 6 (04) : 627 - 632
  • [42] Long-term morphological changes in a cryopreserved pulmonary valve homograft
    Luk, Adriana
    Butany, Jagdish
    Erlich, Sarah A.
    Henry, Jessica
    David, Tirone F.
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (10) : 817 - 819
  • [43] Stentless fresh pulmonary homograft for recurrent mitral prosthetic valve endocarditis
    Renzulli, A
    Cerasuolo, F
    Festa, M
    Caruso, A
    Cotrufo, M
    Vitale, N
    JOURNAL OF HEART VALVE DISEASE, 1997, 6 (03): : 329 - 329
  • [44] Is the "porcelain homograft" a contraindication for transcatheter pulmonary valve implantation? A case report
    Demkow, Marcin
    Ruzyllo, Witold
    Biernacka, Elzbieta K.
    Rozanski, Jacek
    Kusmierczyk, Mariusz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2011, 7 (04): : 323 - 326
  • [45] EVOLUTION OF THE HOMOGRAFT VALVE
    ROSS, DN
    ANNALS OF THORACIC SURGERY, 1995, 59 (03): : 565 - 567
  • [46] "Tailored" endovascular pulmonary valve and root replacement for rupture of a dilated homograft
    Mueller, Goetz Christoph
    Sinning, Christoph
    Zengin-Sahm, Elvin
    Stark, Veronika
    Mir, Thomas S.
    Rickers, Carsten
    Kozlik-Feldmann, Rainer
    Koelbel, Tilo
    Schaefer, Ulrich
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2018, 8 (06) : 820 - 824
  • [47] Structural integrity of collagen and elastin in SynerGraft® decellularized-cryopreserved human heart valves
    Gerson, Cindy J.
    Elkins, Ronald C.
    Goldstein, Steven
    Heacox, Albert E.
    CRYOBIOLOGY, 2012, 64 (01) : 33 - 42
  • [48] MITRAL VALVE REPLACEMENT WITH STENTED AORTIC HOMOGRAFT - A HEMODYNAMIC EVALUATION
    DUNLAP, RW
    FRYE, RL
    ELLIS, FH
    ARCHIVES OF SURGERY, 1969, 99 (06) : 821 - &
  • [49] Successful repair of TOF in an adult along with aortic valve replacement and homograft pulmonary valve replacement
    Sekar K.
    Theodore S.
    Krishnan K.V.
    Ramachandran T.R.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2014, 30 (2) : 164 - 166
  • [50] Valved homograft replacement of aneurysmal pulmonary arteries for severely symptomatic absent pulmonary valve syndrome
    Hew, CC
    Daebritz, SH
    Zurakowski, D
    del Nido, PI
    Mayer, JE
    Jonas, RA
    ANNALS OF THORACIC SURGERY, 2002, 73 (06): : 1778 - 1785