Evaluation of the decellularized pulmonary valve homograft (SynerGraft™)

被引:0
|
作者
Bechtel, JFM
Müller-Steinhardt, M
Schmidtke, C
Brunswik, A
Stierle, U
Sievers, HH
机构
[1] Univ Hosp, Dept Cardiac Surg, Lubeck, Germany
[2] Med Univ Lubeck, Inst Immunol & Transfus Med, D-23538 Lubeck, Germany
来源
JOURNAL OF HEART VALVE DISEASE | 2003年 / 12卷 / 06期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Rejection is thought to contribute to the degeneration of valved homografts. A novel cryopreserved decellularized homograft valve (SynerGraft(TM); CryoLife, Inc.) offers the unique opportunity to gain new insight into the immunology of homograft implantation and its significance for valve function. Methods: Twenty-four patients (group 1; mean age 37 +/- 11 years) underwent implantation of a pulmonary SynerGraft and were examined at one and six months postoperatively; 22 patients (group 11; mean age 41 +/- 17 years) with conventional homografts served as controls. Temperature, C-reactive protein (CRP) levels and white blood cell count (WBC) were studied perioperatively. Follow up included echocardiography and anti-human leukocyte antigen (HLA) class I antibody determination. Results: Significantly lower temperatures were measured in group I (p = 0.019). CRP level and WBC each increased postoperatively, but did not differ between groups. During follow up, none of the SynerGraft patients became positive for anti-HLA antibodies, compared with 66% of controls (p = 0.011). Homograft diameter and valve orifice area were decreased significantly at one month after surgery in groups I and II (25 +/- 1 versus 18 +/- 3 mm; 25 +/- 1 versus 19 +/- 2 mm, respectively; p <0.001 both groups). Transvalvular pressure gradients significantly increased during follow up. Conclusion: Implantation of the SynerGraft pulmonary homograft appeared safe, and though evidence was found of a reduced immunologic response after SynerGraft implantation this (unexpectedly) did not translate into any hemodynamic advantage. Hence, factors other than rejection appear as the main contributions to the observed functional changes.
引用
收藏
页码:734 / 739
页数:6
相关论文
共 50 条
  • [31] A LITERATURE-REVIEW - HOMOGRAFT AORTIC AND PULMONARY VALVE REPLACEMENTS
    ABSHIER, DA
    HOWARD, DP
    CLARKE, DR
    PROCEEDINGS OF THE AMERICAN ACADEMY OF CARDIOVASCULAR PERFUSION, VOL 9, 1988, 9 : 118 - 121
  • [32] TRICUSPID-VALVE REPLACEMENT USING AN UNSTENTED PULMONARY HOMOGRAFT
    MCKAY, R
    SONO, J
    ARNOLD, RM
    ANNALS OF THORACIC SURGERY, 1988, 46 (01): : 58 - 62
  • [33] Scalloped Freehand Pulmonary Homograft for Prosthetic Tricuspid Valve Replacement
    Luciani, Giovanni Battista
    de Manna, Nunzio Davide
    Segreto, Antonio
    Lanzoni, Laura
    Faggian, Giuseppe
    ANNALS OF THORACIC SURGERY, 2021, 112 (01): : E61 - E64
  • [34] Early Failure of Decellularized Pulmonary Valve Conduits - A Word of Caution!
    Rueffer, A.
    Purbojo, A.
    Gloeckler, M.
    Toka, O.
    Cicha, I.
    Seeliger, T.
    Zink, S.
    Koch, A.
    Dittrich, S.
    Cesnjevar, R.
    CLINICAL RESEARCH IN CARDIOLOGY, 2009, 98 (09) : 591 - 592
  • [35] Semilunar Valve Replacement With Decellularized Homograft After Damus-Kaye-Stansel Anastomosis and Fontan Procedure
    Bobylev, Dmitry
    Breymann, Thomas
    Boethig, Dietmar
    Haverich, Axel
    Ono, Masamichi
    ANNALS OF THORACIC SURGERY, 2014, 97 (05): : 1792 - 1795
  • [36] Pulmonary homograft dysfunction after the Ross procedure using decellularized homografts-a multicenter study
    Chauvette, Vincent
    Bouhout, Ismail
    Tarabzoni, Mohammed
    Pham, Magali
    Wong, Daniel
    Whitlock, Richard
    Chu, Michael W. A.
    El-Hamamsy, Ismail
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 163 (04): : 1296 - +
  • [37] In vitro hydrodynamics of a decellularized pulmonary porcine valve, compared with a glutaraldehyde and polyurethane heart valve
    Dohmen, PM
    Scheckel, M
    Stein-Konertz, M
    Erdbruegger, W
    Affeld, K
    Konertz, W
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (11): : 1089 - 1094
  • [38] HOMOGRAFT OF PULMONARY ARTERY OR ASCENDING AORTA WITH VALVE AS A RIGHT VENTRICULAR OUTFLOW
    EGUCHI, S
    ASANO, KI
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1968, 56 (03): : 413 - &
  • [39] The pulmonary homograft as aortic valve substitute: 7 years' follow up
    Mair, R
    Peschl, F
    Gross, C
    Klima, U
    Hinterreiter, H
    Bruecke, P
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (05) : 910 - 915
  • [40] Tetralogy of Fallot with absent pulmonary valve: Simplified technique for homograft repair
    Kirshbom, PM
    Jaggers, JJ
    Ungerleider, RM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (06): : 1125 - 1127